4.2.5 Relay COM Slave (RCS connects the accessories)
RS485 interface:
When the slave is set in RS485 communication mode, i.e., with a combination of the RCS and DS1/DS2 modules, the controller's
information can be displayed by the DS1/DS2 module.
Relay interface:
It shall connect the
controller’s
relay in parallel with the inverter start switch, so it can turn ON/OFF the inverter by operating the button.
30
5 Parameters Setting
5.1 Battery parameters
5.1.1 Supported battery types
1
Battery
Sealed(default)
Gel
Flooded
2
Lithium
battery
LiFePO4(4S/ 8S)
Li(NiCoMn)O2 (3S/6S/7S)
3
User
5.1.2 Local setting
WARNING
When the default battery type is selected, the battery voltage parameters cannot be modified. To change these parameters, select
the "USE" type.
Step1
˖
˖
Enter the “USE” battery type.
Detailed
operations of entering the “USE” battery type
are shown in the following table.
Content
DS1 module operation steps
DS2 module operation steps
Enter the “USE”
battery type
1) Press the
button to jump to the battery voltage
interface, and long-press the
button to enter the
battery-type interface.
2) Press the
button to select the battery type, such as
1) On the initial interface, press the
button to browse
the battery parameters. Press the
button to enter
the battery parameters setting interface, and long-press