HUIZHOU EPEVER TECHNOLOGY CO., LTD. Tel: +86-752-3889706 Website: www.epever.com
1 2
Solar Charge Controller
1 Overview
LS-B series is a PWM common positive solar charge controller that adopts the advanced
digital technique. The multiple load control modes make it suitable for a solar home
system, traffic signal, solar street light, solar garden lamp, etc.
Features
:
Adopt high-quality components of ST, and IR, ensure product lifespan
UL and VDE certification, making the product safer and more reliable
Full load running in the environment temperature range
3-stage intelligent PWM charging: Bulk, Boost/Equalize, Float
Optional four battery types: Sealed, Gel, Flooded, and User
Battery temperature compensation function
Real-energy statistics function
Standard Modbus protocol based on RS485 bus, longer communication distance
Multiple load control modes
Extensive electronic protection
2 Identification of parts
❶
Remote temperature(RTS)port
★
❻
Mounting hole
❷
PV terminals
❼
Load ON/OFF button
❸
Battery terminals
❽
Load status indicator
❹
Load terminals
❾
Battery status indicator
❺
RS485 communication port
❿
Charge status indicator
★
If the temperature sensor is short-circuited or damaged, the controller will charge
or discharge at the default temperature setting of 25 ºC
(no temperature
compensation).
3 Wiring
Installation Procedure:
Connect the system in the order of
❶
battery
❷
load
❸
PV array
, and
disconnect the system in reverse order
❸❷❶
.
NOTE: While wiring the controller, disconnect the circuit breaker or fast-
acting fuse. Ensure that the polarity of the electrode is connected correctly.
NOTE: A fast-acting fuse whose current is 1.25 to 2 times the rated current
must be installed on the battery side with a distance from the battery not
longer than 150 mm.
NOTE: The LS-B series is a positive ground controller. Any positive solar,
load, or battery connection shall be earth grounded as required.
NOTE: If an inverter is to be connected to the system, connect the inverter
directly to the battery, not to the load side of the controller.
4 Indicator and button
(1) Indicator
Indicator
Color
Status
Information
Green
On solid
PV connection normal ,but
low voltage(low irradiance)
from PV, no charging
Green
OFF
No PV voltage(night time) or
PV connection problem
Green
Slowly flashing(1Hz)
In charging
Green
Fast flashing(4Hz)
PV over voltage
Green
On solid
Battery normal
Green
Slowly flashing(1Hz)
Battery full
Green
Fast flashing(4Hz)
Battery over voltage
Orange
On solid
Battery under voltage
Red
On solid
Battery over-discharged
Red
Slowly flashing(1Hz)
Battery over temperature
Red
On solid
Load ON
Red
OFF
Load OFF
Red
Slowly flashing(1Hz)
Overload
Red
Fast flashing(4Hz)
Load short circuit
Charge, Load, and Battery(orange)indicator flashing
Controller over temperature
Charge, Load, and Battery(red)indicator flashing
System voltage error
(2) Button
①
The load is turned ON/OFF via the button when the operating mode is Manual Control.
②
Clear the faults for the overload and load short circuit.
5 Setting
❶
USB to RS485 converter cable: CC-USB-RS485-150U
Download PC software:
(PC Software for the Solar Charge Controller)
❷
USB to RS485 converter cable: CC-USB-RS485-150U
OTG cable: OTG-12CM
Download the phone APP (support Andriod system only)
(Andriod APP for the Solar Charge Controller)
❸
RS485 to RS485 converter cable: CC-RS485-RS485-200U-MT
(1) Battery voltage control parameters
(
Below values are measured in the 12V/25 ºC system; please double the values in the 24V
system.)
Battery type
Sealed
Gel
Flooded
User
Over Voltage Disconnect Voltage
16.0V
16.0V
16.0V
9
~
17V
Charging Limit Voltage
15.0V
15.0V
15.0V
9
~
17V
Over Voltage Reconnect Voltage
15.0V
15.0V
15.0V
9
~
17V
Equalize Charging Voltage
14.6V
——
14.8V
9
~
17V
Boost Charging Voltage
14.4V
14.2V
14.6V
9
~
17V
Float Charging Voltage
13.8V
13.8V
13.8V
9
~
17V
Boost Reconnect Charging Voltage
13.2V
13.2V
13.2V
9
~
17V
Low Voltage Reconnect Voltage
12.6V
12.6V
12.6V
9
~
17V
Under Voltage Warning Reconnect
Voltage
12.2V
12.2V
12.2V
9
~
17V
Under Voltage Warning Voltage
12.0V
12.0V
12.0V
9
~
17V
Low Voltage Disconnect Voltage
11.1V
11.1V
11.1V
9
~
17V
Discharging Limit Voltage
10.6V
10.6V
10.6V
9
~
17V
Equalize Duration
120 min
——
120 min 0
~
180 min
Boost Duration
120 min 120 min
120 min
10
~
180
min
NOTE:
1) When the battery type is sealed, gel, or flooded, the adjusting range of equalizing
duration is 0 to180 minutes, and boost duration is 10 to180 minutes.
2) The following rules must be observed when modifying the value of the parameter in the
user battery type (factory default value is the same as the sealed type):
A.
Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging
Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect
Charging Voltage.
B.
Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage.
※
Thank you for selecting the LS-B series solar charge controller.
Please read this manual carefully before using the product.
※
Do not install this product in humid, salt spray, corrosion,
greasy, flammable, explosive, dust accumulative, or other
severe environments.