Epever LS-B Series Скачать руководство пользователя страница 1

                                       

HUIZHOU EPEVER TECHNOLOGY CO., LTD.                                            Tel: +86-752-3889706                                                    Website: www.epever.com

 

                                                         

 

1                                                                                                                                                  2

 

 

 

 

 

 

Solar Charge Controller

 

1 Overview                                                                                                                                                                                 

LS-B series is a PWM common positive solar charge controller that adopts the advanced 
digital technique. The multiple load control modes make it suitable for a solar home 
system, traffic signal, solar street light, solar garden lamp, etc. 

Features

 

  Adopt high-quality components of ST, and IR, ensure product lifespan 

  UL and VDE certification, making the product safer and more reliable 

 

Full load running in the environment temperature range

 

 

3-stage intelligent PWM charging: Bulk, Boost/Equalize, Float

 

 

Optional four battery types: Sealed, Gel, Flooded, and User

 

 

Battery temperature compensation function

 

 

Real-energy statistics function

 

 

Standard Modbus protocol based on RS485 bus, longer communication distance

 

 

Multiple load control modes

   

 

Extensive electronic protection

 

2 Identification of parts                                                                                                 

 

 

Remote temperature(RTS)port

 

 

Mounting hole

 

 

PV terminals

 

 

Load ON/OFF button

 

 

Battery terminals

 

 

Load status indicator

 

 

Load terminals

 

 

Battery status indicator

 

 

RS485 communication port

 

 

Charge status indicator

 

 

If the temperature sensor is short-circuited or damaged, the controller will charge 

or  discharge  at  the  default  temperature  setting  of  25  ºC

 

(no  temperature 

compensation).

 

3 Wiring                                                                                                     

             

 

Installation Procedure:

 

Connect  the  system  in  the  order  of 

battery

  

  load

 

PV  array

 ,  and 

disconnect the system in reverse order

❸❷❶

.

 

NOTE: While wiring the controller, disconnect the circuit breaker or fast-

acting fuse. Ensure that the polarity of the electrode is connected correctly.

 

NOTE: A fast-acting fuse whose current is 1.25 to 2 times the rated current 

must be installed on the battery side with a distance from the battery not 

longer than 150 mm.

 

NOTE: The LS-B series is a positive ground controller. Any positive solar, 

load, or battery connection shall be earth grounded as required.

 

NOTE: If an inverter is to be connected to the system, connect the inverter 

directly to the battery, not to the load side of the controller.

 

4 Indicator and button                                                                           

(1) Indicator 

Indicator

 

Color 

Status 

Information 

 

Green 

On solid 

PV  connection  normal  ,but 
low  voltage(low  irradiance) 
from PV, no charging 

Green 

OFF 

No PV voltage(night time) or 
PV connection problem 

Green 

Slowly flashing(1Hz) 

In charging 

Green 

Fast flashing(4Hz) 

PV over voltage 

 

Green 

On solid 

Battery normal 

Green 

Slowly flashing(1Hz) 

Battery full 

Green 

Fast flashing(4Hz) 

Battery over voltage 

Orange 

On solid 

Battery under voltage 

Red 

On solid 

Battery over-discharged 

Red 

Slowly flashing(1Hz) 

Battery over temperature 

 

Red 

On solid 

Load ON 

Red 

OFF 

Load OFF 

Red 

Slowly flashing(1Hz) 

Overload 

Red 

Fast flashing(4Hz) 

Load short circuit 

Charge, Load, and Battery(orange)indicator flashing 

Controller over temperature 

Charge, Load, and Battery(red)indicator flashing 

System voltage error 

(2) Button 

 

The load is turned ON/OFF via the button when the operating mode is Manual Control. 

 

Clear the faults for the overload and load short circuit. 

5 Setting                                                                                                               

 

 USB to RS485 converter cable: CC-USB-RS485-150U

 

Download PC software:

 

www.epever.com

(PC Software for the Solar Charge Controller) 

 USB to RS485 converter cable: CC-USB-RS485-150U

 

OTG cable: OTG-12CM 

Download the phone APP (support Andriod system only) 

www.epever.com

(Andriod APP for the Solar Charge Controller) 

 RS485 to RS485 converter cable: CC-RS485-RS485-200U-MT 

(1) Battery voltage control parameters 

(

Below values are measured in the 12V/25 ºC system; please double the values in the 24V 

system.)

 

Battery type 

Sealed 

Gel 

Flooded 

User 

Over Voltage Disconnect Voltage

 

16.0V 

16.0V 

16.0V 

9

17V 

Charging Limit Voltage

 

15.0V 

15.0V 

15.0V 

9

17V 

Over Voltage Reconnect Voltage

 

15.0V 

15.0V 

15.0V 

9

17V 

Equalize Charging Voltage

 

14.6V 

——

 

14.8V 

9

17V 

Boost Charging Voltage

 

14.4V 

14.2V 

14.6V 

9

17V 

Float Charging Voltage

 

13.8V 

13.8V 

13.8V 

9

17V 

Boost Reconnect Charging Voltage

 

13.2V 

13.2V 

13.2V 

9

17V 

Low Voltage Reconnect Voltage

 

12.6V 

12.6V 

12.6V 

9

17V 

Under Voltage Warning Reconnect 

Voltage

 

12.2V 

12.2V 

12.2V 

9

17V 

Under Voltage Warning Voltage

 

12.0V 

12.0V 

12.0V 

9

17V 

Low Voltage Disconnect Voltage

 

11.1V 

11.1V 

11.1V 

9

17V 

Discharging Limit Voltage

 

10.6V 

10.6V 

10.6V 

9

17V 

Equalize Duration

 

120 min 

——

 

120 min  0

180 min 

Boost Duration

 

120 min  120 min 

120 min 

10

180 

min 

NOTE: 

1) When the battery type is sealed, gel, or flooded, the adjusting range of equalizing 

duration is 0 to180 minutes, and boost duration is 10 to180 minutes. 

2) The following rules must be observed when modifying the value of the parameter in the 

user battery type (factory default value is the same as the sealed type): 

A.

 

Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging 

Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect 

Charging Voltage. 

B. 

Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage. 

  Thank you for selecting the LS-B series solar charge controller. 

Please read this manual carefully before using the product.

 

  Do  not  install  this  product  in  humid,  salt  spray,  corrosion, 

greasy,  flammable,  explosive,  dust  accumulative,  or  other 

severe environments.

 

Отзывы: