background image

 

           

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

IP350-Plus,

   

IP500-Plus 

IP1000-Plus, IP1500-Plus 

IP2000-Plus, IP3000-Plus 

IP4000-Plus, IP5000-Plus 

 

 

 

 

Pure sine wave inverter 

 

USER MANUAL 

Содержание IP1000-Plus

Страница 1: ...IP350 Plus IP500 Plus IP1000 Plus IP1500 Plus IP2000 Plus IP3000 Plus IP4000 Plus IP5000 Plus Pure sine wave inverter USER MANUAL...

Страница 2: ......

Страница 3: ...LCD interface 16 5 3 1 Real time interface 16 5 3 2 Parameters setting 16 5 3 3 Power Saving Mode 16 5 3 4 Parameters user define 18 5 4 Error code 19 6 Installation 20 6 1 Attentions 20 6 2 Wire siz...

Страница 4: ...eration if ignored may cause the device to run in error CAUTION Indicates potential hazards if not avoided may cause the device damaged WARNING Indicates the danger of electric shock if not avoided wo...

Страница 5: ...e damaged This inverter is only allowed for stand alone operation It is prohibited to connect multiple units in parallel or series Otherwise the inverter will be damaged 5 Safety cautions for mechanic...

Страница 6: ...will be caused to the inverter Do not connect battery chargers or other similar products to the input terminal of the inverter Otherwise the inverter will be damaged 7 Safety cautions for controller...

Страница 7: ...e contact our service personnel WARNING Do NOT touch or open the shell after the inverter is powered off within ten minutes 10 Safety cautions for inverter maintenance It is recommended to check the i...

Страница 8: ...so suitable for occasions with high power quality requirements Features Completely electrically isolated design for input and output Full digital double closed loop control Excellent EMC characteristi...

Страница 9: ...er for the IP350 Plus series Configure the parameters via the local LCD meter no including the IP350 Plus series remote LCD meter phone Apps or PC software This function is unavailable for inverters w...

Страница 10: ...T terminal C Chinese dual socket N North America Appearance without decorative cover is suitable for AC output of A Australia E European F French UK United Kingdom IP500 xx Plus Appearance with decor...

Страница 11: ...8 Appearance without decorative cover is suitable for AC output of A Australia E European F French UK United Kingdom IP1000 xx Plus IP1500 xx IP2000 2x IP2000 4x IP3000 42 Plus...

Страница 12: ...9 IP2000 1x Plus IP3000 1x Plus IP3000 2x Plus...

Страница 13: ...wer IPower Plus full range Conditions to stop the cooling fan Heat sink temperature is lower than 40 and The internal inverter temperature is lower than 40 and The output power is lower than 30 of the...

Страница 14: ...nese dual socket TC Terminal Chinese E European socket TE Terminal European A Australia socket TA Terminal Australia UK United Kingdom socket TUK Terminal United Kingdom F French socket TF Terminal Fr...

Страница 15: ...d it indicates that the GFCI outlet is damaged please replace a new one 2 If the LED is green ON after it flashes in red three times connect the circuit breaker and the night light will be turned on T...

Страница 16: ...ection diagram IP350 xx Plus take the Appearance with decorative cover as an example IP500 xx Plus take the Appearance with decorative cover as an example IP1000 xx IP1500 xx IP2000 2x IP2000 4x IP300...

Страница 17: ...0 4x Plus CAUTION It is recommended to connect the inverter DC input terminal to the battery terminal directly DO NOT connect it to the charge source terminal Otherwise the charging voltage spikes of...

Страница 18: ...y 5 2 Buttons Click Move up parameter increase Press for 2s In the real time interface press it for 2s to enter the setting interface In the setting interface press it for 2s to enter the parameters c...

Страница 19: ...the parameter setting interface Step2 Click or to select the parameter to be configured Step3 Press for 2s to enter the configuration interface of the specified parameter Step4 Click or to configure t...

Страница 20: ...tton to set the PSE status Select ON to enable the power saving mode Select OFF to disable the power saving mode Step5 Press and hold the button to confirm 2 Set the power to exit the power saving mod...

Страница 21: ...etting parameter cannot exceeds the user define or it will back to the initial value to start the loop Step4 Press and hold the button to confirm 5 3 4 Parameters user define Display Parameters Defaul...

Страница 22: ...matically It will resume work according to the new parameter value Due to the length limit of the LCD displayed data when the baud rate is set to 115200 the value displayed on the LCD is 1152 For the...

Страница 23: ...ording to the current density of 3 5A mm2 or less Avoid direct sunlight and rain infiltration when installing it outdoor After turn off the power switch do not open or touch the internal component imm...

Страница 24: ...allel IP3000 12 Plus 25mm2 3AWG RNB80 10 DC 125A 3P in parallel IP3000 21 Plus 25mm2 3AWG RNB60 6 DC 100A 2P in parallel IP3000 22 Plus 25mm2 3AWG RNB60 6 DC 100A 2P in parallel IP3000 41 Plus 25mm2 3...

Страница 25: ...P 16A IP2000 21 Plus 4mm2 11AWG AC 2P 32A IP2000 22 Plus 2 5mm 13AWG AC 2P 16A IP2000 41 Plus 4mm2 11AWG AC 2P 32A IP2000 42 Plus 2 5mm 13AWG AC 2P 16A IP3000 11 Plus 6mm2 10AWG AC 2P 50A IP3000 12 Pl...

Страница 26: ...from the inverter s upper and lower edges CAUTION It is not recommended to install the product in an enclosed cabinet where the device cooling will be influenced If mounted in an enclosure cabinet ens...

Страница 27: ...nnected correctly The terminals and ports on the side vary from the product models Wiring sequence The following wiring sequence is illustrated in the appearance IP2000 2x Plus wiring positions of oth...

Страница 28: ...ads connection WARNING The AC loads shall be determined by the continuous output power of the inverter The surge power of the AC load must be lower than the instantaneous surge power of the inverter o...

Страница 29: ...int when selecting the multi stranded wire and directly insert it into the corresponding port Stop the inverter before removing the wiring Then insert a sharp tool into the small hole on the top of th...

Страница 30: ...RS485 A 2 5VDC 6 RS485 A 3 RS485 B RS485 B 7 GND Power GND 4 RS485 B 8 GND 2 Connect optional accessories 5 USB port connection USB port is not available for inverters with 48V input voltage Step 4 P...

Страница 31: ...large impulse current is recommended And then turn on the load with a smaller impulse current after the load output is stable If the fault indicator flashes red and the buzzer alarms after powering t...

Страница 32: ...Low voltage disconnect voltage 1V D Low voltage disconnect voltage Low voltage limiting voltage 10 5 21 42V Detail status is shown as the following when the input voltage protection occurs Input volt...

Страница 33: ...Rated power The output is switched OFF after 30 seconds Buzzer beeps The red indicator slowly flashes LCD displays the S 1 8Pe S Output power Pe Rated power The output is switched OFF after 10 seconds...

Страница 34: ...ps The red indicator slowly flashes LCD displays the S 1 7Pe S Output power Pe Rated power The output is switched OFF after 5 seconds Buzzer beeps The red indicator slowly flashes LCD displays the IP5...

Страница 35: ...CD displays the Note The AC output is recovered automatically three times recover after 5s 10s 15s separately After the recovery attempt failed three times you need to restart the inverter to recover...

Страница 36: ...heck whether the DC input voltage is higher than16 32 64V by a multimeter The inverter will resume work after adjusting the input voltage Red indicator slowly flashes Buzzer beeps Overload Reduce the...

Страница 37: ...indicator display is consistent with the actual operation Confirm that terminals have no corrosion insulation damage high temperature burnt discolored sign and tighten terminal screws to the suggeste...

Страница 38: ...istive load Load power factor 0 2 1 Load power Continuous output power Rated input voltage 12VDC 24VDC 12VDC 24VDC Input voltage range 10 8 16 0VDC 21 6 32VDC 10 8 16 0VDC 21 6 32VDC Rated output effi...

Страница 39: ...A 100A 50A Output voltage 100VAC 110VAC 3 120VAC 7 3 Output frequency 50 60Hz 0 2 Output wave Pure Sine Wave Output distortion THD THD 4 Resistive load THD 3 Resistive load THD 4 Resistive load Load p...

Страница 40: ...5S Surge current when power on 100A 100A 50A Output voltage 100VAC 110VAC 3 120VAC 7 3 Output frequency 50 60Hz 0 2 Output wave Pure Sine Wave Output distortion THD THD 5 Resistive load THD 4 Resisti...

Страница 41: ...800W 5S 6000W 5S 6000W 5S 8000W 5S Surge current when power on 100A 100A 65A 65A Output voltage 100VAC 110VAC 3 120VAC 7 3 Output frequency 50 60Hz 0 2 Output wave Pure Sine Wave Output distortion THD...

Страница 42: ...2 Plus IP500 22 Plus Continuous output power 350W 35 Rated input voltage 500W 35 Rated input voltage Surge power 700W 5S 1000W 5S Surge current when power on 30A 50A Output voltage 220VAC 3 230VAC 6 3...

Страница 43: ...1500 12 Plus IP1500 22 Plus IP1500 42 Plus Continuous output power 1000W 35 Rated input voltage 1500W 35 Rated input voltage Surge power 2000W 5S 3000W 5S Surge current when power on 100A 100A 50A Out...

Страница 44: ...arameters IP2000 12 Plus IP2000 22 Plus IP2000 42 Plus Continuous output power 2000W 35 Rated input voltage Surge power 4000W 5S Surge current when power on 100A 100A 50A Output voltage 220VAC 3 230VA...

Страница 45: ...us IP3000 22 Plus IP3000 42 Plus IP4000 42 Plus IP5000 42 Plus Continuous output power 3000W 35 Rated input voltage 4000W 35 Rated input voltage 5000W 35 Rated input voltage Surge power 6000W 5S 8000W...

Страница 46: ...kg 8 0kg 7 0kg 8 0kg 9 0kg It is measured in the condition of continuous output power and rated input voltage It means the max output efficiency when the inverter is connected with different loads und...

Страница 47: ...the rated range Arc fire explosion and other accidents are caused by failure to follow the inverter stickers or manual instructions Disassemble and repair the inverter without authorization Damage ca...

Страница 48: ...HUIZHOU EPEVER TECHNOLOGY CO LTD Tel 86 752 3889706 E mail info epever com Website www epever com...

Отзывы: