HUIZHOU EPEVER TECHNOLOGY CO., LTD. Tel
:
+86-10-82894896/8286-752-3889706 Website
3
4
6 Network connection
one to one network connection
one to more network connection
Note: EPEVER-RTU-4G-C is compatible with the short-distance LORA wireless transmission
terminals. Up to 100 pcs LORA slave terminals can be connected through one LORA master.
Working principle:
1) The controllers, inverters, or inverter/chargers transmit the feedback data
to the EPEVER-RTU-4G-C.
2) The EPEVER-RTU-4G-C transmits the received data to the cloud server
for recording and processing via the 4G and Internet network.
3) According to the set timing task and user terminal command, the cloud
server
continues
to
transmit
the
data
and
commands
to
EPEVER-RTU-4G-C.
4) The EPEVER-RTU-4G-C transmits data and commands to the controllers,
inverters, or inverter/chargers for execution. After finished, return to Step
1)
for a loop.
7 Troubleshooting
Faults
Solutions
Power
indicator off
1. Check
whether
to
supply
power
to
the
EPEVER-RTU-4G-C.
2. Check whether the indicators are damaged.
3. If powered, check whether the positive and negative
poles of the power supply are connected inversely.
The input terminal of the EPEVER-RTU-4G-C is
equipped with anti-reverse protection. The reverse
connection shall not cause fatal damage to the
product. However, it affects the normal running
before the correct connection is restored.
WORK
Indicator on
solid
After power is on, the WORK indicator will be on solid in
60 seconds. While it cannot flash after 60 seconds,
please check below:
1. Check whether the SIM card is inserted correctly.
2. Confirm the SIM card has activated the GPRS
service.
WORK indicator on solid again after running for a
period, please check:
1. Check whether the cloud server is normally running.
2. Check whether the SIM card is loose or arrear.
The product
emits smoke
with a
pungent
smell.
The actual input voltage exceeds the rated voltage of
the
EPEVER-RTU-4G-C,
causing
the
internal
components to burn out. Don't hesitate to contact the
supplier in time and send it to the manufacturer.
The device
can't register
to the
network.
1. Check whether the SIM card is inserted correctly.
2. Confirm the SIM card has activated the GPRS
service.
3. Check whether the input power is sufficient. The
input voltage shall be DC8~64V or DC5V.
Parameters
can't be
configured.
1. Check whether the connection to the PC is correct.
2. Check whether the serial port's selection is correct.
8 Specifications
Model
Parameter
EPEVER-RTU-4G-C
Input voltage
DC8~64V or DC5V(Supply by the battery)
Power consumption
Peak emission voltage: 5V@200mA
Idle voltage: 5V@40mA
Working frequency
2.4~2.4835GHz
Configuration methods
Cloud server, PC software, serial port
command, SMS command
Transmission protocol
EPEVER IoT communication protocol V1.1
Communication method
RS485
Communication cable
Included: RS485 to 5.08
cable(CC-RJ45-5.08-150U)
Optional: 3.81 to 5.08
cable(CC-3.81-5.08-100U)
Communication
standard
The male head standard in "Communication
Interface Standard V-1.1"
Baud
9600Bps
~
115200bps, 8N1
Antenna connector
50Ω SMA (female head)
Antenna gain
2.5dBi ~ 5dBi
Working temperature
-40
℃
~
85
℃
Enclosure
IP54
Humidity range
5
~
95%(NC.)
Dimensions
98Mm×86mm×24mm
(Include the antenna and handle)
Mounting dimension
75mm / 75×25mm
Mounting Holes
Φ4 / Φ3
Net Weight
198g
9 Disclaimers
The warranty does not apply to the following conditions:
Damage caused by improper use or inappropriate environment.
The parameter setting exceeds the terminal's limit.
Damage caused by working temperature exceeds the rated range.
Unauthorized dismantling or attempted repair.
Damage caused by force majeure.
Damage occurred during transportation or handling.
Any changes without prior notice! Version number: V1.1