Epever DR1106N-DDB Скачать руководство пользователя страница 32

28

 

when its temperature is below 55 °C. 

BATT1Low 

Temperature(Lithiu

m Battery) 

When the temperature detected by the optional temperature 

sensor  is  lower  than  the  Low  Temperature  Protection 

Threshold  (LTPT),  the  controller  will  stop  charging  and 

discharging automatically. When the detected temperature is 

higher than the  LTPT, the  controller  will  work  automatically 

(The  LTPT  is  0  °C  by  default  and  can  be  set  within  10  ~ 

-40 °C). 

Controller 

Overheating

 

The  controller  can  detect  the  temperature  inside  the 

controller. The controller stops working when its temperature 

exceeds 85 °C and restarts to work when its temperature is 

below 75 °C. 

TVSHigh 

Voltage 

Transients

 

The  internal  circuitry  of  the  controller  is  designed  with 

Transient  Voltage  Suppressors  (TVS),  which  can  only 

protect  against  high-voltage  surge  pulses  with  less  energy. 

Suppose the controller is to be used in an area with frequent 

lightning strikes. In that case, it is recommended to install an 

external surge arrester. 

4.2 Troubleshooting 

Faults phenomenon 

Possible 

reasons 

Troubleshooting 

Charging  LED  indicator  off  during 

daytime when sunshine falls on PV 

modules properly 

PV 

array 

disconnection 

Confirm 

that 

PV 

wire 

connections  are  correct  and 

tight. 

The wire connection is correct, and 

the controller is not working. 

Battery  voltage 

is  lower  than 

8.5V 

Please  check  the  battery 

voltage

—at  least  8.5V  to 

activate the controller. 

DDS: 

  Red fast flashing 

 

 

 

BATT1over 

voltage 

Check if the battery voltage is 

higher 

than 

OVD 

(over-voltage 

disconnect 

voltage),  and  disconnect  the 

PV. 

Battery  level  shows 

full, 

battery 

frame 

blink, fault icon blink 

Содержание DR1106N-DDB

Страница 1: ...MPPT Dual Battery Solar Charge Controller User Manual DR1106N DDB DDS DR1206N DDB DDS DR2106N DDB DDS DR2206N DDB DDS DR3106N DDB DDS DR3206N DDB DDS DR2210N DDB DDS DR3210N DDB DDS...

Страница 2: ......

Страница 3: ...ller Do NOT disassemble or attempt to repair the controller Avoid direct sunlight and high temperature and do NOT install the controller at locations where water can get in Install the controller in w...

Страница 4: ...2 6 1 6 AES Signal Port 7 2 Installation 10 2 1 Attentions 10 2 2 PV Array Requirements 10 2 3 Wire Size 11 2 4 Mounting 13 3 Display units 17 3 1 DuoRacer Display Basic DDB 17 3 2 DuoRacer Display St...

Страница 5: ...When there is no operation for a long time and the charging conditions cannot be satisfied the controller switches to the low power mode It helps reduce self consumption and saves the battery power t...

Страница 6: ...al LED and LCD units AES control signal for car refrigerators to avoid energy waste Standard Modbus protocol and RS485 5V 200mA communication port for the customer to expand the application area Main...

Страница 7: ...BATT2 terminals Grounding Terminal RS485 Communication port Remote temperature sensor port AES signal output port PV terminals Terminal protection cover The controller charges the BATT1 as default 25...

Страница 8: ...t is built into a power switching device 1 4 Battery charging stage Note The following instructions for the battery charging stage are suitable for the main battery BATT1 Charging instructions for the...

Страница 9: ...flooded batteries would produce explosive gases so well ventilation of the battery box is recommended CAUTION Equipment damage Equalization may increase battery voltage to the level that damages sensi...

Страница 10: ...the solar panel Suppose loads power exceeds the solar array s power In that case the controller will no longer maintain the battery voltage in the float charging stage When the battery voltage goes lo...

Страница 11: ...ess than 2 5A Condition 3 BATT2 stops charging when BATT2 reaches the Full Voltage CAUTION After the BATT2 charging is turned off it will be recharged only when the start charging conditions are satis...

Страница 12: ...er of 5VDC Max 200mA Connect the accessories AES ADP adapter when connecting the refrigerator refer to the below picture CAUTION The AES signal port and RS485 port share the power of 5VDC Max 200mA Th...

Страница 13: ...tor Indicate BATT1 power ON AES signal indicator Light on with an AES signal Light off without an ASE signal Main Parameters Applicable DR1206 2206 3206 2210 3210N DDB DDS Input Voltage 8 5V 35V Outpu...

Страница 14: ...t them from swaying in the mobile application The controller can work with lead acid and lithium batteries within its control scope The battery connection may be wired to one battery or a bank of batt...

Страница 15: ...000W m2 Module Temperature 25 Air Mass 1 5 DR2210 3210N DDB DDS System voltage 36cell Voc 23V 48cell Voc 31V 54cell Voc 34V 60cell Voc 38V Max Best Max Best Max Best Max Best 12V 4 2 2 1 2 1 2 1 24V 4...

Страница 16: ...sumed to be identical Isc Short circuit current amps Voc Open circuit voltage Model Max PV input current Max PV wire size DR1106N DDB DDS DR1206N DDB DDS 10A 4mm2 12AWG DR2106N DDB DDS DR2206N DDB DDS...

Страница 17: ...nly device connected to this cable no inverter connected to the same cable etc 2 4 Mounting WARNING Risk of explosion Never install the controller in a sealed enclose with flooded batteries Do not ins...

Страница 18: ...if installed in a closed area Suppose the controller is to be installed in an enclosed box In that case ensuring reliable heat dissipation through the box is important Step2 Wiring Connect the system...

Страница 19: ...ding terminal on the controller s shell must be grounded It may effectively shield the electromagnetic interference from the outside and prevent electric shock to the human body CAUTION A common negat...

Страница 20: ...fic application Check the 1 5 AES Signal output port instruction for more information Step6 Power on the controller 1 Firstly turn on the BATT2 safety switch and check the BATT2 charging indicator sta...

Страница 21: ...ast flashing 4Hz BATT1 over temperature or BATT1 low temperature Green On solid Connect to BATT1 and in charging Green Slowly flashing 0 2Hz Connect to BATT1 and no charging Green OFF Not connect BATT...

Страница 22: ...icator Slowly flashing 0 2Hz 2 Battery type indicator Indicator Color Status Instruction Sealed Green On solid 12V system Flashing 24V system Gel Red On solid 12V system Flashing 24V system Flooded Gr...

Страница 23: ...s within 90 If the angle exceeds 90 the information on the display screen cannot be viewed clearly Charging indicator Indicator Color Status Instruction Green On solid PV charges the battery with a lo...

Страница 24: ...2 charging icon Display the parameters of BATT1 BATT1 temperature parameters Display the parameters of BATT2 AES signal icon Setting icon Battery type icon Auto global browsing icon Minimum voltage ic...

Страница 25: ...ink Fault icon blinks and battery frame blink No alarm for system voltage error when BATT1 is a lithium battery Buttons Press the button Parameters of PV array Parameters of BATT1 Parameters of BATT2...

Страница 26: ...e Min BATT1 voltage BATT1 temperature BATT1 battery type BATT2 voltage BATT2 current Max BATT2 voltage Min BATT2 voltage PV voltage 2 Change Temperature units Operation Step1 Press the button under th...

Страница 27: ...p3 Press the button to confirm the battery type Battery type BATT112V Sealed BATT124V Sealed BATT112V Gel BATT124V Gel BATT112V Flooded BATT124V Flooded LiFePO4 4S LiFePO4 8S Li NiCoMn 3S Li NiCoMn 6S...

Страница 28: ...ng Volt 12 0V 12 0V 12 0V Low Volt Disconnect Volt 11 1V 11 1V 11 1V Discharging Limit Voltage 10 6V 10 6V 10 6V Equalize Duration min 120 120 0 180 Boost Duration min 120 120 120 10 180 The DR1106 21...

Страница 29: ...nect Volt 11 0V 9 3V Discharging Limit Voltage 10 8V 9 3V The DR1106 2106 3106N DDB DDS voltage is 9 16V The following rules must be followed when modifying the value of a lithium battery A Over Volta...

Страница 30: ...ry BMS voltage parameters to set the lithium battery voltage parameters The required accuracy of BMS shall be at least 0 2V If the deviation exceeds 0 2V the manufacturer will assume no liability for...

Страница 31: ...controller may not be damaged and resume normal operation after the mis wiring is corrected NOTE Limited to the lithium battery s characteristic when the PV connection is correct either the BATT1 or...

Страница 32: ...r is designed with Transient Voltage Suppressors TVS which can only protect against high voltage surge pulses with less energy Suppose the controller is to be used in an area with frequent lightning s...

Страница 33: ...ry or reset the working voltage System voltage alarms when using the Lead acid battery for the BATT1 System over discharge alarms when the BATT1 is set as 24V battery type Its actual voltage is 12V Sy...

Страница 34: ...re connections Check and confirm that LED or LCD is consistent with the required Pay attention to any troubleshooting or error indication Take necessary corrective action Confirm that all the system c...

Страница 35: ...urrent 10A 20A 30A 10A 20A 30A 20A 30A BATT2 Rated Charge Current 1A Battery Input Voltage Range 8 5 16V 8 5 32V Max PV Open Circuit Voltage 60V 46V 100V 92V MPP Voltage Range Battery Voltage 2V 36V B...

Страница 36: ...115200 default LCD backlight time 60S default When the lithium battery is 12V and the BMS is protected the lithium battery voltage may rise to 17V DR 106N or 35V DR 206N DR 210N It may damage the load...

Страница 37: ...n against solid objects protected against solid objects over 2 5mm 3 protected against sprays to 60 from the vertical Pollution degree PD2 Mechanical Parameters Item DR1106 1206N DDB DDS DR2106 2206 2...

Страница 38: ...34 Annex I Dimension Diagrams DR1106 1206N DDB DDS Unit mm...

Страница 39: ...35 DR2106 2206 2210N DDB DDS Unit mm...

Страница 40: ...36 DR3106 3206 3210N DDB DDS Unit mm Any changes without prior notice Version number 2 4...

Страница 41: ......

Страница 42: ......

Страница 43: ......

Страница 44: ...HUIZHOU EPEVER TECHNOLOGY CO LTD Tel 86 752 3889706 E mail info epever com Website www epever com...

Отзывы: