  | RT Series True Online UPS

3. Installation

•  Open the UPS package and inspect the contents upon receipt. The accessories attached to the UPS contain 

a power cord, a user manual, communication cable, CD-ROM. The long backup model also includes the 
cable for connection to battery bank.

•  Check if the unit is damaged during transport. Do not power on and notify the carrier and dealer if find 

damaged or parts missing.

•  Verify this unit is the model you want to buy. Check the model name showed both on the front panel and 

rear panel.

•  The UPS installation environment must be in good ventilation, away from water, flammable gases and 

corrosive entities.

•  Do not lie down the UPS against the wall so that front and side panel air intake hole, rear panel air outtake 

hole will be unobstructed.

•  The ambient temperature around the UPS should be within 0  ~ 40°C (non-condensing).
•  If dismantling the machine at low temperatures, there may be condensation droplets, users can not install 

or operate it before UPS completely got dry both inside and outside, otherwise there will be danger of 
electric shocks.

•  Place the UPS near the mains source so that can cut off utility power without any delay in case of 

emergency.

•  Make sure the load connected to the UPS is off when users connect it to UPS, and then turn on the load one 

by one later.

•  Connect the UPS with the power outlet which is over-current protected. Do not connect the UPS with 

power outlets whose rated current is less than the maximum input current of this UPS.

•  All power outlets should be configured with earthing device for safety.
•  UPS could be electrified or powered no matter the input power cord is tied or not, even when the UPS is off. 

The only way to cut off the output is switching off the UPS and disconnecting the mains power supply.

•  For all standard model UPS, it is advised to charge the batteries over 8 hours before using. Once the AC 

mains power energizes the UPS, it will automatically charge the batteries. Without prior charging, UPS 
output remains as usual but with shorter back-up time than normal.

•  When connected to motor, display equipment, laser printer etc, UPS power selection should be based on 

the startup power of the load which is usually twice as rated power.

•  Wiring by a qualified electrician is required. Ensure input cables and output cables are connected correctly 

and firmly.

•  If install a leakage current protective switch, please install it on output cable.
•  For 1-3K series long backup model units, you may need to prepare wires for terminals based on the 

following table.

3.1  Unpacking Inspection

3.2  Installation Information

Keep the packaging box and packaging materials for future transport use. 
The equipment is heavy. Always handle it with care.

Note:

Содержание 1KVAH-RT

Страница 1: ...Epcom Power Line RT Series True Online UPS 1 RT Series User Manual TRUE ONLINE UPS 1KVA 3KVA...

Страница 2: ...may cause electric shocks and have a high short circuit current follow below requirements before installing or replacing the batteries 1 1 UPS Safety Information Note Symbol Instructions 1 2 Battery...

Страница 3: ...and 100 load 176 280Vac no derating 280 300Vac power derating 50 Input frequency range 40 70Hz PFC 0 99 THDI 6 Bypass voltage range 25 15 settable Output Output voltage 208Vac 220Vac 230Vac 240Vac set...

Страница 4: ...over 90 capacity in 3 hours for standard models Charging current Max Standard model 1 A 0 15 Long time model 6 A 3 A 0 5 System Control and Communications Protections Over temp protection Fan testing...

Страница 5: ...it might be different from the figure Model Type Model Type 1KVAS RT 1KVA Standard model 1KVAH RT 1KVA Long backup model 2KVAS RT 2KVA Standard model 1KVAH RT 2KVA Long backup model 3KVAS RT 3KVA Stan...

Страница 6: ...it to UPS and then turn on the load one by one later Connect the UPS with the power outlet which is over current protected Do not connect the UPS with power outlets whose rated current is less than th...

Страница 7: ...are instructed to configure different battery voltage as below table More or less units are forbidden or else something abnormal or faulty will appear One end of battery cable is for UPS terminals whi...

Страница 8: ...s green Users can cut off the output of UPS immediately by operating EPO port in case of emergency Normally pin1 and pin2 are connected so that the machine can be working normally When some emergenci...

Страница 9: ...the rear panel of the UPS it s for SNMP card and dry contacts Users can insert any type intelligent card from those three into it to monitor and manager the UPS And users don t have to turn off the UP...

Страница 10: ...ode Press or for more than half a second less than 2 seconds display the items orderly Press for more than 2 seconds Circularly and orderly display the items every 2 seconds when press the key for som...

Страница 11: ...ntage 0 25 26 50 51 75 and 76 100 is indicated by the number of load bar sections illuminated When UPS is overloaded the load icon will flash Mute Icon Indicates the audible alarm is disabled mute Pre...

Страница 12: ...ormation Digital Display Area In non setting mode it displays UPS output information when UPS normally runs Fault code will be told in fault mode In setting mode users could adjust different output vo...

Страница 13: ...rt UPS The operation of UPS startup process is almost same as above process with mains power After the self test finishes UPS will work in battery mode Turn Off the UPS Turn off the UPS in Line mode P...

Страница 14: ...erical value press and hold the function setting for more than half a second less than 2 seconds Now the setting function is completed and the numerical value illuminates without flashing Exit from th...

Страница 15: ...D voltage automatically varies with loads including 21 5 hours dicharge protection Frequency Converter Enable Disable C L I N E 22 0 s0 0 25 50 75 100 25 50 75 100 VAC Hz L I N E 25 50 75 100 25 50 75...

Страница 16: ...display will have nine option 240V 230V 220V 208V 100V 110V 115V 120V 127V but the voltage output is still four option 240V 230V 220V 208V You can choose to shield the LCD display capacity values when...

Страница 17: ...0 75 100 25 50 75 100 w KVA L I N E 900 10 25 50 75 100 25 50 75 100 L I N E C 40 25 50 75 100 25 50 75 100 VAC Hz L I N E 220 500 75 100 75 100 S T D B Y 220 25 50 75 100 25 50 75 100 V S T D B Y 600...

Страница 18: ...up is ON Turn off the UPS in line mode and the bypass setup is ON Overload in line mode Note When UPS is working in bypass mode it has no back up function Line Mode Being in line mode are as following...

Страница 19: ...he UPS turns to fault mode UPS cuts off the output and LCD displays fault codes At the moment users can press the mute key to make the buzzer stop beeping temporarily to wait for maintenance Users can...

Страница 20: ...nder Bypass Working mode displays byPASS One beep 2 mins Mains power high voltage war ning under Bypass Working mode displays byPASS One beep 4 sec Mains power low voltage warning under Bypass Working...

Страница 21: ...m code S N Working Status LCD Display Messages Alarm Beep 5 Output Overload Protection Warning for mains power overload Working mode displays Line load icon flash 2 beeps sec Protect operation for mai...

Страница 22: ...left Display Value Bypass Lost Remote Shutdown Overload Battery Disconnected 0 1 2 3 4 5 6 7 8 9 A B C D E F The second digital tube from right to left Display Value Overcharging Warnings Mains Revers...

Страница 23: ...Value EEPROM Abnormal Fan Abnorma Low Battery Low Battery 0 1 2 3 4 5 6 7 8 9 A B C D E F The fourth digital tube from right to left Display Value Over Load Fault Mains Lost Bypass Abnormal 0 1 2 3 4...

Страница 24: ...plier Fault icon display audible buzzer alarm continually the fault code is 40 44 Over temperature inside overloaded and the fan vent is not obstructed as well as the indoor temperature is not high Le...

Страница 25: ...fail to start when operate On key Pressing time too short Press the power key more than 2 seconds to start the UPS The input connection is not ready or UPS internal battery disconnect Connect the inp...

Страница 26: ......

Отзывы: