5
GB
Equipment
Output
Voltage
in kW
Nominal
Voltage
Fuse in A
Cross-section
in mm²
SteamTec
Basic
4,5
400 V 3 N
AC 50 Hz
3 x 16
5 x 2,5
6,0
9,0
Technical specifi cations
• Before you put the sauna up please read these instructions carefully and keep
them for reference in
a safe place.. You will fi nd a great deal of useful advice on
how to set up your sauna safely and expertly.
• After you have unpacked everything, please check carefully that no part of the
steam generator is missing or damaged during transport. EOS does not accept
any liability for any damage that has occurred in transit during storage.
Delivery includes:
• Steam generator
• wall mounting template
• 4 screws 45 x 40
• 4 dowels M8
• Union 1“ - 35 mm
• 0.5 m steel-coated pressure tube 3/8 - 500
- 3/4
• 0.4 m fl ex tube 28 - 22
• 5 L container for descaling liquid with level
probe
• Owner‘s manual
1. Erecting the frame
Complete the building according to the
plans.
1.1.Fresh water and dirty water
The way in which the pipes for the fresh
water and the dirty water are posiitoned
should be done with the help of the dril-
ling template which is included with the
materials
1.2.Electrical wiring
The electrical wiring must take into full
consideration the requisite conductor
cross-section. The mains electricity must
be connected in accordance with DIN
VDE 0100. There must be a separate cir-
cuit for the system. The steam generator
must have a separate FI switch (IΔ = 30
mA) forsafety reasons so that the equip-
ment has a circuit breaker with a contact
opening of at least 3 mm from the mains
supply. The electricity should be connec-
ted to the mains only by a qualifi ed elec-
trician.
X
= This area is for the cable duct piping
to be used for the electricity supply lines
(control panel, temperature sensor, etc.)