6
GB
ON/OFF
ON/OFF
Returning to timer operation
The resetting is only possible, if the coinbox
is separated and the wire jumper „L1-Time“
is mounted (see connection diagram).
2 Persons are required for this procedure.
• Disconnect radiator completely from the
power supply.
88
0
The radiator is now timer operated.
• While one person keeps the button (2)
and the not marked button simultaneously
pressed, the other person shall connect
the radiator to the power supply again.
• Keep pressing both buttons until “88” ap-
pears on the timer display.
• The display will go out thereafter.
A not marked button is located between
the ON/OFF and the button (2). This
button has no function when pressed
alone, but is required for returning to the ti-
mer operation.
Fig. 8
Fig. 9
Switching to coin box operation
2 persons are required for this procedure.
• When the coin box is not connected yet,
separate the appliance completely from
the power supply.
• While one person keeps the [up] and
[down] buttons at the timer control panel
simultaneously pressed (see fi g. 8), the
other person shall connect the radiator to
the power supply.
• When the coin box is already connected,
the radiator must not be disconnected
from the power supply.
In this case proceed as follows:
- one person keeps the [up] and [down]
buttons at the timer control panel simulta-
neously pressed.
- the other person shall start the coin box
running by throwing in a coin (token).
• Keep pressing the [up] and [down] buttons
until “0” appears on the timer display.
The radiator is now coin box operated.
After being released by the coin box the
time will start counting from “0” minutes up-
wards.
The radiator can be turned on or off within
this time.
The [up] and [down] buttons are locked, the
other buttons remain functional.
The pre-set time has elapsed, the radiator
will be completely switched off and time dis-
play will go out.