Service settings
5.1.7 Setting the ECO runtime
This function allows you to define a window of time during which the
cabin temperature is lowered.
In an IR-only cabin, the ambient temperature is lowered as follows:
IR temperature operating mode: The temperature is lowered using the
following formula: T
ECO
= T
Target
- ((T
Target
- 30)/2).
Example:
T
ECO
= (65- (65-30)/2)
T
ECO
= 65-17.5
T
ECO
= 47.5°C.
IR intensity operating mode: The intensity is reduced by half.
IR emitters connected to IR-3 are shut off completely.
The window of time can be set to a value between 0 and 240 minutes in
30 minute-increments.
The setting is useful if there are intermissions in operation to prevent the
cabin from cooling down completely.
The ECO function is switched on via the control panel or via a push button
that is available as an option. It is automatically switched off after the
defined duration or ended by pressing the push button.
Setting the ECO function runtime
1
Open the service settings.
See 5.1.1 Opening service settings,
2
: Select and confirm.
°C
IR
ECO
09:11