The electrical installation may be accomplished only by a certifi ed electrician
subject to the regulations of the local power utility company and those of the VDE.
In general, there can only be one permanent connection to the power supply network, to include
a device which allows the unit to be disconnected from the power source with a contact distance
of at least 3 mm from all terminals.
All electrical installations and connector cables inside the cabin must be able to withstand tempera-
tures up to 140°C. Please use the table below to determine the required cable diameters for this task.
LSG
5 5
5
4
5
4
Saunasteuergerät
Control unit
Boîtier de commande
Пульт управления
Saunaheizgerät
Sauna heater
Poêle de sauna
Печь для сауны
Leistungsschaltgerät
Power extension unit
Extension de puissance
Блок расширения мощности
Netz / Mains / Réseau / Сеть
Connection diagram
The power control unit is delivered equipped for a voltage of 400 V 3N AC with a maximum brea-
king capacity of 16 A per phase and with a safety shutdown in connection with our sauna control
unit as standard.
Installation and connection of the sauna systems and other electrical equipment may be
undertaken only by an expert; please note that this is subject to VDE 0100, Part 703/2006-02..
Sauna systems may be connected to the power supply only by hard wire.