![EOS Compact DP Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/eos/compact-dp/compact-dp_installation-and-operating-instructions-manual_2417002043.webp)
EOS Compact DP/HP - Installation and Operating Instructions
EN-43
Connecting the lines
Setting the heating period limitation
1
Set the lower jog dial:
Set the jog dial with the screwdriver as supplied in the scope of
delivery.
Position
Heating period limitation settings
Max. 6 hrs runtime: private or commercial operation
Max. 12 hrs runtime: commercial operation, e.g. in blocks of flats
and hotels
Max. 18 hrs runtime: commercial operation and if the cabin is con-
tinuously supervised, e.g. in public saunas
In Bi-O mode, a max. of 17:30 hrs can be set, since 0:30 hrs are
included for the drying program.
Infinite runtime (24 hrs/7 days): commercial operation and if the
cabin is continuously supervised, e.g. in public saunas
S T B
Oven Sens.