30
Installation Instructions - EmoTouch 3
Mounting
EN
The control line should be routed between the insulation and the outer
wall of the cabin. Cabin insulation must be installed in such a way that the
temperature of the external wall cannot exceed 35°C. If the line is installed
on the cabin's exterior wall, it should be protected by a cable conduit.
Extending the control panel's control line
The control line may be extended to approx. 50 m, if necessary.
If the line length is greater than 25 m, a special bus amplifier (accessory)
with power supply must also be installed near the control panel and con-
nected to it. The bus amplifier requires a 230 V mains connection at a dis-
tance of max. 1.5 m from the installation location.
The extension is attached to the side of the relay box. This requires a cou-
pling (RJ12/RJ12) and an extension cord with an RJ12 plug (optional acces-
sory).
4.4.2 Mounting the control panel
The control lines are connected to the control panel. Depending on the
system installation, they lead to the cabin, to the relay box, and to the con-
trol panel. These control lines are fed through the bottom of the housing.
Therefore, they must be installed once the cut in the wall has been made.
Necessary steps:
Create wall cut-out and lay the control line,
Plugging in the control panel,
Tools required:
Saw for wall cut-out
Phillips screwdriver
Removal tool to loosen the display (included in the scope of delivery)
Taut wire, as needed
Содержание 94 6505 00