Simplex & Duplex 

Typical Installation 

Instructions 

& Warranty 

Information

476-Gal. Capacity

Grinder Pump Station

Содержание Extreme WH47 Series

Страница 1: ...1 WH47 WR47 Series Simplex Duplex Typical Installation Instructions Warranty Information 476 Gal Capacity Grinder Pump Station...

Страница 2: ...others 9a STUB OUT 4 X 5 long watertight stub out to be installed at time of burial unless the gravity serviceline is connected during installation Supplied by others 10 DISCHARGE FTG 1 1 4 Female NPT...

Страница 3: ...3 FAILURE TO COMPLY WITH INSTALLATION INSTRUCTIONS WILL VOID WARRANTY Figure 1...

Страница 4: ...standard grommet for connecting the 4 DWV 4 50 outside dia incoming sewer drain Other inlet types and sizes are optional Caution 4 DR 35 pipe has a smaller diameter and won t create a watertight joint...

Страница 5: ...o 2 of concrete onto the gravel bed and place the tank into the excavation Ensure the tank is properly positioned in the excavation to support inlet pipe Section 3 and discharge pipe Section 5 connect...

Страница 6: ...and local code requirements must be accounted for when determining the inlet location The supply cable path should be considered when selecting the inlet location see Section 8 A 5 diameter field pene...

Страница 7: ...n There is a stainless steel 1 25 NPT female discharge connection on the outside of the tank to support discharge piping connection 6 BACKFILL REQUIREMENTS Proper backfill is essential to the long ter...

Страница 8: ...n the station and the alarm panel supply cable for each grinder pump The supply cable a six conductor tray cable meets NEC requirements for direct burial as long as a minimum of 24 burial depth is mai...

Страница 9: ...valves at the street main that must also be open Ignore all Trouble indications LEDs and or messages until the panel is reset at the end of this procedure For model WH WR 471 b Fill the tank with app...

Страница 10: ...flange attached to the upper part of the accessway These will act as guides while aligning the bolt pattern of the two flanges 5 Support the upper accessway section a few inches over the tank with th...

Страница 11: ...11 Figure 7 ALLOWABLE INLET LOCATIONS INLET INSTALLATION...

Страница 12: ...12 Figure 8 Figure 9 Figure 10 Figure 11...

Страница 13: ...tion or move it on its side 2 No Ballast to be poured in place If the concrete anchor is to be poured while the station is in place lift the unit using two nylon straps wrapped under the tank flange t...

Страница 14: ...soil Section I Used To Determine The Volume Of Concrete Note 4 0 ft assumed inside diameter of concrete ballast ring around tank s bottom flange Volume Height Area 83 ft 5 6 ft 2 4 0 ft 2 4 83 ft 12...

Страница 15: ...Height in Station Volume cu ft Fnet Buoyant lbs Tank Weight lbs Fballast lbs Volume Concrete cu ft Weight Concrete in Air cu ft Min Diameter of Concrete Anchor in Min Thickness of Concrete Anchor in 7...

Страница 16: ...16...

Страница 17: ...oud 5a Welded on shroud standard Using a hand saw cut the tank in the valley between the two corrugations at grade discard existing welded on shroud and attached corrugations shroud is not to be reuse...

Страница 18: ...18 Environment One Corporation 2773 Balltown Road Niskayuna New York 12309 1090 Voice 01 518 346 6161 Fax 518 346 6188 www eone com NA0245P01 Rev F 10 18 A Precision Castparts Company...

Страница 19: ...Sanitary napkins or tampons Cigarette butts Caution Kitchen garbage disposals do not keep grease oil out of the plumbing system In addition you must never introduce into any sewer Explosives Strong c...

Страница 20: ...provided the product is properly installed serviced and operated under normal conditions and according to manufacturer s instructions Repair or parts replacement required as a result of such defect wi...