Envoy CXiR Скачать руководство пользователя страница 2

Selecting the operating frequency

You  can  check  or  change  the  operating  frequency  of  the 

CX

iR receiver via infra-red control using the SwitchiR.

To check the CX

iR frequency:

 Press 

MENU

. The display shows:

FREQUENCY

MHz

FREQUENCY

z

H

M

x

R

 854.900

  Fr

 Align the front of the Switch

iR with the infra-red window 

on the receiver and press 

OK

. Optimum operating range 

is  between  5  and  15cm.  The  Switch

iR  will  display  the 

receiver frequency; for example:

FREQUENCY

MHz

FREQUENCY

z

H

M

x

R

 854.900

  Fr

To change the CX

iR frequency:

 Press 

OK

 again. The display will alternately flash between 

frequency and channel number. For example:

CHANNEL

CHANNEL

FREQUENCY

z

H

M

x

R

     01

     32

 857.950

 Error

 Press 

 or 

 to scroll through the 32 frequencies read 

from the receiver until the required channel or frequency 

is displayed. For example:

CHANNEL

CHANNEL

FREQUENCY

z

H

M

x

R

     01

     32

 857.950

 Error

 Align the front of the Switch

iR with the infra-red port on 

the receiver and press 

OK

. If the command was received 

correctly  the  display  will  show  the  new  frequency.  For 

example:

CHANNEL

CHANNEL

FREQUENCY

z

H

M

x

R

     01

     32

 857.950

 Error

  Otherwise the display will show:

CHANNEL

CHANNEL

FREQUENCY

z

H

M

x

R

     01

     32

 857.950

 Error

Repeat  the  above  steps  if  an  error  message  is  displayed, 

moving the Switch

iR closer to the infra-red port.

Setting the output level

The CX

iR should be set to the correct level as required by the 

camcorder. The output level is attenuated in 1dB steps over 

a 32dB range. The 0dB reference level is -25dBu.

To check the CX

iR output level:

 Press 

MENU

.

 Press 

  once until the display shows:

 AF LEVEL

TxRx

 AF LEVEL

Rx

 AF LEVEL

TxRx

  AF

 -07 dB

 -15 dB

 Align  the  front  of  the  Switch

iR  with  the  infra-red  port 

on the receiver and press 

OK

. The display will show the 

current output level setting; for example:

 AF LEVEL

TxRx

 AF LEVEL

Rx

 AF LEVEL

TxRx

  AF

 -07 dB

 -15 dB

To change the receiver output level:

 Press the 

OK

 button. The AF level display will flash.

 Press the 

 or 

 button to step between the available 

output  level  settings  until  the  required  output  level  is 

displayed. For example:

 AF LEVEL

TxRx

 AF LEVEL

Rx

 AF LEVEL

TxRx

  AF

 -07 dB

 -15 dB

 Align the front of the Switch

iR with the infra-red port on 

the receiver and press 

OK

. If the command was received 

correctly the new level will be displayed. For example:

 AF LEVEL

TxRx

TxRx

Rx

Tx

 -15 dB

 Error

 BAtt

  11.9 v

    H

  Otherwise the display will show:

 AF LEVEL

TxRx

TxRx

Rx

Tx

 -15 dB

 Error

 BAtt

  11.9 v

    H

 Repeat the above steps if an error message is displayed, 

moving the Switch

iR closer to the infra-red port.

Checking the DC power status

To check the status of the receiver’s DC power:

 Press 

MENU

.

 Press 

 three times until the display shows:

 AF LEVEL

TxRx

TxRx

Rx

Tx

 -15 dB

 Error

 BAtt

  11.9 v

    H

 Align the front of the Switch

iR with the infra-red port on 

the receiver and press 

OK

. The display will show the DC 

voltage:

 AF LEVEL

TxRx

TxRx

Rx

Tx

 -15 dB

 Error

 BAtt

  11.9 v

    H

  If  the  associated  transmitter  is  on  while  the  DC  status 

is  being  checked  the  display  will  alternate  between  the 

receiver’s  DC  status  and  the  received  transmitter  DC 

status. For example:

 AF LEVEL

TxRx

TxRx

Rx

Tx

 -15 dB

 Error

 BAtt

  11.9 v

    H

User Guide

 

CX

iR Diversity Receiver

Отзывы: