ENVISION POOL HEATER INSTALLATION MANUAL

To Change Between Pool and Spa Setpoints Manually:

This is the default factory setting (jumper on pins 1-2) 
and allows the use to change between the pool and spa 
setpoints by using the mode button located on the front 
control panel. The use of an external water pressure switch 

IS NOT

 required for this mode of operation.

To Change Between Pool and Spa Setpoints Automatically:

This change can be done automatically as the water flow 
is directed to either the pool or spa. The use of an external 
water pressure switch in the spa piping 

IS

 necessary. A 

two-wire control circuit must be connected from the water 
pressure switch to the terminals 9 and 10 on the terminal 
strip located in the electrical control enclosure. The mode 
jumper must be on pins 2-3 for this mode of operation. See 
the Terminal Strip and Mode Configuration Pins illustration 
for pin settings.

Remote Thermostats and Controllers:

If a remote thermostat or another control system is to be 
used to operate the heater, a normally open dry contact 
can be made at terminals 11 and 12 on the terminal strip 
located in the electrical control enclosure. Remove the 
red jumper from terminals 11 and 12 on the terminal strip 
and install the remote control system. The mode jumper 
must be on pins 3-4 for this mode of operation. See the 
Terminal Strip and Mode Configuration Pins illustration for 
pin settings.

4

3

2

1

Mode

Configuration Pins

Removable

Jumper

Electronic

Controller

1
2
3
4
5
6
7
8
9

10

11

12

Terminal

Strip

Terminal Strip and Mode Configuration Pins

Electronic Control Panel

Control Settings

Temperature Setpoint

Temperature setpoint maximum for POOL mode is 95°F 

• 

(35°C).
Temperature setpoint maximum for SPA mode is 140°F 

• 

(40°C).

To change the temperature setpoint, press the POOL/
SPA/STANDBY button until you reach either POOL or SPA 
mode, this will prompt the control to display the current 
temperature setpoint. Hold either UP or DOWN button to 
scroll to your desired temperature setpoint. Once your new 
temperature setpoint has been reached, release the UP 
or DOWN button. Your new setpoint will be displayed for 
fifteen seconds then revert back to the actual pool or spa 
water temperature.

NOTE:

 When the mode jumper is in position 3-4, the 

setpoint must be changed on the remote control system.

Selecting Pool or Spa Mode

Press the POOL/SPA/STANDBY button until you reach the 
desired mode. The LED indicator light will verify the mode 
that has been selected. NOTE: When the mode jumper is in 
position 2-3 or 3-4 the mode is determined by the external 
water pressure (flow) switch or remote controller.

Modes of Operation

Содержание AC-1750B

Страница 1: ...Installation Information Water Piping Connections Chemical Use Electrical Startup Procedures Preventive Maintenance Troubleshooting IM1009PN 07 10 Envision Pool Heater Installation Manual Pool Heater ...

Страница 2: ......

Страница 3: ...ntroduction 4 General Performance 4 Installation 4 Water Flow and Connections 5 Chemical Use 5 Electrical Connections 6 Electrical Data 6 Electronic Control Panel 7 Modes of Operation 7 Wiring Schematic 8 Startup Procedures 9 Preventive Maintenance 10 Troubleshooting 10 ...

Страница 4: ...manual was prepared to assist in the proper installation operation maintenance and service of your new heat pump pool heater Please read the entire manual and follow all instructions Improper installation and use can result in damage to the heater unsatisfactory operation and may void the warranty Retain this manual for quick reference Installation When selecting a location consider the following ...

Страница 5: ...rain Skimmer Check Valve Chlorine Gas Trap Ball Valves Filter Pump In Out Heat Pump Pool Heater Heat Pump Pool Heater In Out Pump Filter From Main Drain Skimmer Return Ball Valve For Flow Rates Greater than 70 gpm or Pumps Larger than 1 5 H P Typical Installation Installation with In line Chlorinator Installation with Pool and Spa Chemical Use Water quality must be checked regularly and maintained...

Страница 6: ...uit directly to the electrical control enclosure will ensure a moisture tight seal extending the life of the heater Attach grounding conductor to the ground lug provided 4 inside the electrical control enclosure Install L1 and L2 input conductors to the input lugs of 5 the compressor contactor Connect bond wire at least 8 solid copper wire from 6 bond lug on the right side of coil header plate to ...

Страница 7: ...minal strip and install the remote control system The mode jumper must be on pins 3 4 for this mode of operation See the Terminal Strip and Mode Configuration Pins illustration for pin settings 4 3 2 1 Mode Configuration Pins Removable Jumper Electronic Controller 1 2 3 4 5 6 7 8 9 10 11 12 Terminal Strip Terminal Strip and Mode Configuration Pins Electronic Control Panel Control Settings Temperat...

Страница 8: ...Remote Automation Microprocessor Control TEST PIN CC HP LP DC WT FS1 FS2 Field Installed Flow Switch See Table 1 Remote Automation Jumper P1 P2 P3 PIN 1 2 3 Field Installed home automation control See Table 1 See Table 1 Fan1 Interface Panel 9 10 11 12 TS 4 Green 7 8 1 2 TS 3 4 5 6 24 LP LP HP HP CC CCG F2 F1 C PIN 1 X3 X3 X2 X2 X1 X1 WAT WAT FP FP Compre ssor Unit Po wer Su pply 208 230 60 1 CC T...

Страница 9: ... conductive A pool cover solar blanket may reduce initial heating time by up to 50 Defrost Cycle The heat pump pool heater has automatic defrost When the outdoor temperature drops below 40 F frost may start to form on the evaporator coil Frost buildup will be heaviest on humid days when the temperature is between 35 40 F During the defrost cycle the Defrost LED will be illuminated to indicate that...

Страница 10: ...reakers or replace fuses if necessary Check to be sure the electronic control panel is set 2 properly The unit must be in either the POOL or SPA mode and the desired temperature must be set above the actual pool or spa temperature for the heater to run If an error code is displayed reference the table below to determine the cause Check to make sure the evaporator coil has enough 3 clearance and th...

Страница 11: ......

Страница 12: ...l Inc 9000 Conservation Way Fort Wayne IN 46809 www waterfurnace com 2010 WaterFurnace International Inc 9000 Conservation Way Fort Wayne IN 46809 9794 WaterFurnace has a policy of continual product research and development and reserves the right to change design and specifications without notice IM1009PN 07 10 ...

Отзывы: