Envision One cDLM® User Manual
TS-MAM-EnvisionOneCDLMUserManual-V5.0-FN-EN , 2021-12-15
Page 40 of 73
8.6
Move & Calibration Tab
The
Move & Calibration
tab is used for moving the build platform and calibration of Home position.
8.6.1
Move
This tab allows the operator to move the build platform along the Z-axis.
Tap
Settings | Move & Calibration | Move
to open the tab.
Tap the
up
and
down
arrows to move the platform up and down correspondingly.
•
Zero position
is the highest position of the build platform along the Z-axis.
•
Home position
is the start position of the build platform for printing.
•
Safe position
is the safe position of the build platform between Zero position
and Home position for
•
Dry position
is the lowest position of the build platform along the Z-axis. It is used for calibration of the
platform while the material tray is empty of the material.
8.6.2
Home Calibration
Tap
Settings | Move & Calibration | Home Calibration
to open the tab.
For detailed information, see the section
of this User Manual.
8.6.3
Mask Generation
Step-by-step:
1. Insert the empty material tray to the material tray holder.
2.
On the main screen of the Envision One Control Software, tap
Settings | Move & Calibration | Mask
Generation
.
→ The following message appears.
3. Select a resolution (Low, Medium or High) in the
Resolution
field.
NOTICE
Resolution defines the number of measurements that need to be done. The higher the resolution,
the more measurements are needed.
NOTICE
The spot size is set automatically based on the printer type and build envelope size.