background image

PROFILE-100 AXIAL EXTRACTOR FANS 
Suitable for bathroom applications 
 
INSTALLATION 

 

IMPORTANT: before installing and wiring the unit, ensure that the mains supply 
is disconnected. 
 
PROFILE-100 should only be used in conjunction with fixed wiring. 
 
Fig.1 

 

– Grille 

– Fixing screw for front cover 

– Connection terminals 

– Outlet 

– Cable entry point 

 
The  PROFILE-100  is  suitable  for  panel,  ceiling  or  wall  mounting  (for  wall 
mounting applications using EnviroVent wall kit) (fig. 2). 
 

 

Drill a hole in chosen position in the panel, ceiling or wall of size Ø105mm in 
diameter.  If  the  unit  is  to  be  installed  with  ducting,  use  standard  duct  size 
Ø100mm. 

 

 

The  hole  for  the  duct  should  be  angled  downwards  to  prevent  rainwater 
running through the duct into the unit. 

 

 

Loosen the screw (2), which holds the grille in place (1) and remove grille. 

 

 

Place  the  extractor  against  the  internal  wall  or  ceiling.  For  a  wall  mounted 
fan  the  terminal  block  should  be  at  the  bottom.  Mark  the  4  screw  hole 
positions. Drill, plug and screw the extractor in position. 

 

 

Check that the wall tube is not distorted and that the impeller turns freely. 

 

 

Once the cable has been introduced through one of the cable points (5), fix 
to the wall.  

 

 

This fan must be installed by a competent person. Complete electrical wiring 
of  fan  as  outlined  in  the  Wiring  Instructions  below.  Then  refit  the  grille  and 
tighten the screw (2). 

 
 

WIRING 

 
IMPORTANT:  ENSURE  THAT  THE  MAINS  SUPPLY  IS  SWITCHED  OFF 
BEFORE MAKING ELECTRICAL CONNECTIONS. 

Содержание PROFILE-100

Страница 1: ...PROFILE 100 Installation and Wiring Instructions ...

Страница 2: ...make sure that the product corresponds to the one you have ordered and that the details on the instruction plate fulfil your requirements IMPORTANT BE SURE TO HAVE READ AND UNDERSTOOD THESE INSTRUCTIONS BEFORE BEGINNING THE INSTALLATION PROCESS SAFETY AND RECOMMENDATIONS All wiring must comply with Building Regulations and the current I E E Wiring Regulations BS7671 or the equivalent standards for...

Страница 3: ...INSTALLATION PROFILE 100 Fig 1 1 4 3 2 5 Ø 105 mm ...

Страница 4: ...INSTALLATION PROFILE 100 Fig 2 ...

Страница 5: ...Fig 3 Fig 5 Fig 4 L N L N L N ...

Страница 6: ...Fig 6 Fig 7 Fig 8 60 90 2 20 Hr 60 90 Hr 60 90 t min 2 20 t min 2 20 L N L N Fig 9 ...

Страница 7: ...00mm The hole for the duct should be angled downwards to prevent rainwater running through the duct into the unit Loosen the screw 2 which holds the grille in place 1 and remove grille Place the extractor against the internal wall or ceiling For a wall mounted fan the terminal block should be at the bottom Mark the 4 screw hole positions Drill plug and screw the extractor in position Check that th...

Страница 8: ...table timer The timer enables the fan to continue running for the selected period after the switch has been turned off Fig 5 Fan operating through an independent switch Fig 6 Fan operating through a light switch The desired run on time is selected by means of an adjuster positioned on the printed circuit board Fig 7 and is accessible once the grille 1 is removed To reduce the run on time turn anti...

Страница 9: ...riod set on the timer after the light switch has been switched off ATTENTION When the humidity rises above the selected value the automatic option takes precedence over the manual and the unit cannot then be switched off using a switch Settings The fans are set to operate at 60 relative humidity and with 2 minutes run on time If the humidity in the room is lower than 60 the fan will not turn on If...

Страница 10: ...riod The desired run on time is selected by means of an adjuster positioned on the printed circuit board fig 7 and accessible once the grille 1 has been removed To reduce the run on time turn anticlockwise min 1 minute To increase the run on time turn clockwise max 30 minutes CLEANING AND MAINTENANCE IMPORTANT DISCONNECT FROM THE MAINS SUPPLY BEFORE CARRYING OUT CLEANING OR MAINTENANCE To ensure o...

Страница 11: ...e stated within this booklet In the event of any failure of the fan within two years of supply excluding only wilful or careless damage we will exchange the fan free of charge EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA Name and address of purchaser Model Date of purchase Dealer stamp ...

Страница 12: ...EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 www envirovent com info envirovent com Ref 9023007403 ...

Отзывы: