FILTERLESS EXTRACT FAN

INSTALLATION GUIDE FOR ENGINEER / INSTALLER

SELV - IPX5

230V - IPX4

AFTER INSTALLATION THE END USER SHOULD 

KEEP THIS GUIDE FOR FUTURE REFERENCE

DO NOT THROW AWAY

Содержание FILTERLESS EXTRACT FAN SELV Series

Страница 1: ...FILTERLESS EXTRACT FAN INSTALLATION GUIDE FOR ENGINEER INSTALLER SELV IPX5 230V IPX4 AFTER INSTALLATION THE END USER SHOULD KEEP THIS GUIDE FOR FUTURE REFERENCE DO NOT THROW AWAY...

Страница 2: ...nsure the operation of the unit does not affect the operation of open flue appliances If you are unsure please consult local regulations or a qualified gas engineer Consider the external cowl location...

Страница 3: ...ied flexible cable not a solid core lighting and mains cable If any other type of cable is forced into the cable gland the unit will be damaged voiding the warranty If the mains cable is damaged it mu...

Страница 4: ...s Extract Fan 01423 859 395 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL US ON Diagrams Duct Adaptor Rear Carcass Central Cartridge Impeller Front Cover 195mm 129mm 174mm 78mm 99mm 56mm...

Страница 5: ...nector Block Connect the local isolator to the Mains as part of the fixed wiring Connect the N and L connectors of the fan power cable to the local isolator The red 12V cable from the unit must be con...

Страница 6: ...l increase as humidity levels rise and decrease as humidity levels fall This intelligent function reduces energy costs motor wear and ensures a long life for the product Pullcord If your Filterless Ex...

Страница 7: ...ttom of the unit leave the screws in place and remove the front cover 2 Pull the central cartridge out from inside the rear carcass 3 Disconnect the green connector end of the power cable from the uni...

Страница 8: ...the labelled fixing holes and the four screws and wall plugs provided 7 If using a backdraught shutter insert it fully The disc must open towards the outside of the property Do not fit this if the un...

Страница 9: ...lied screws 11 To change unit settings adjust switches 1 and 2 on the central cartridge a Default 230V duty is kitchen humidity tracking b Default SELV duty is bathroom humidity tracking 9 10 11b SELV...

Страница 10: ...Not using this will void the warranty and IP rating 13 Ensure the impeller is fitted correctly the two clips should both be engaged 14 Replace the front cover ensuring the pullcord sits into the slot...

Страница 11: ...t cover in place The unit will not operate until the front cover is fitted Does the pullcord activate Ensure the pullcord is not trapped inside the unit ON SITE INSTALLATION AFTER SALES SERVICE Please...

Страница 12: ...ds the centre then pull the impeller out 3 Clean the front cover and impeller in warm soapy water and allow to dry Use a damp cloth to clean any other parts of the unit Do not use solvents and do not...

Страница 13: ...tal Energy Cost Per Year Bathroom on Trickle 1 22 1 20 1 97 Bathroom on Boost 7 2 0 77 Kitchen on Trickle 2 22 2 41 5 15 Kitchen on Boost 25 2 2 74 Setting Power W Duty l s Bathroom on Trickle 1 8 Bat...

Страница 14: ...ed the unit will operate at the maximum extraction rate It will remain at this rate until the switch is deactivated Two Speed Only The unit is available in a two speed variant without humidity trackin...

Страница 15: ...fect or break down that arises due to faulty materials or construction Please note that a receipt will be required as proof of purchase Units bought from an unapproved source including but not limited...

Страница 16: ...portant to us as we strive to improve our products services and overall customer experience Please email us to help us serve you better feedback envirovent com Delivering innovative and sustainable ve...