background image

15

WARRANTY

The ECO dMEV products are covered by a two year warranty, subject to 
the specifi ed maintenance stated within this booklet.

If your fan has been supplied and installed by EnviroVent it is covered 
with a full parts and labour warranty. If you detect a fault, please con-
tact us on 0345 27 27 810. You will be given guidance over the phone, 
or an arrangement may be made for a member of our team to visit 
(call-out charges may apply if a fault cannot be identifi ed).

Supply Only

If your fan has been supplied by EnviroVent and installed by a third 
party, it is covered by a parts only warranty. If you detect a fault and the 
product has been installed in accordance to the fi tting/wiring instruc-
tions, relevant guidance documents and by a competent and qualifi ed 
person (proof may be required), please return the product to the place 
of purchase for a replacement.

Warranty Conditions & Exclusions

Please note that a receipt will be required as proof of purchase. Fans 
bought from an unapproved source, including but not limited to auc-
tion websites, are not covered by the warranty.

•  The system must be correctly installed and operated according to 

the instructions contained in the user guide supplied.

•  The warranty will be rendered invalid if the system has been ser-

viced, maintained, repaired, taken apart or tampered with by any 
person not authorized, which in any way contradicts the instruction 
guide set out by EnviroVent.

•  The warranty does not cover accidental damage, misuse or abuse.
•  The warranty is in addition to your statutory or legal rights.

Содержание ECO DMEV

Страница 1: ...ECO DMEV ECO DMEV SELV ...

Страница 2: ...2 LJ D ...

Страница 3: ...3 LJ E 3 3 3 6 6 6 6 6 ...

Страница 4: ...4 LJ ...

Страница 5: ...5 Fig 3 L N J2 GND LS J1 LS N L 17V L N ECO dMEV 230Vac 50 60Hz CT 17 18 230Vac 50 60Hz 0 17V DC ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 6: ...6 Fig 4 J2 GND LS J1 LS N L 17V CT 17 18 230Vac 50 60Hz L N 230Vac 50 60Hz N L 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 7: ...7 Fig 5 J2 GND LS J1 LS N L 17V CT 17 18 230Vac 50 60Hz L N 230Vac 50 60Hz N L 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 8: ...8 Fig 6 L N J2 GND LS J1 LS N L 17V L N 230Vac 50 60Hz CT 17 18 230Vac 50 60Hz 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 9: ...9 Fig 8 Fig 7 P2 min P3 HR P2 min ...

Страница 10: ... country This appliance can be used by children aged from 8 years and above and persons with re ducedphysical sensory or mental capabilities or lack of experience and knowledge if they have been given su pervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Chil dren shall not play with the appliance Cleaning and user maintenance shall not be ma...

Страница 11: ...roduced proceed using the electrical wiring dia gram applicable to the selected model OPERATION The ECO dMEV is an extract fan de signed to operate continuously at low speed and constant volume The constant flow setting is made with dip switches placed on the electronic circuit board Fig 1b 15 4 22 6 30 9 36 10 45 13 m 3 h l s S 54 15 SW dip switch position Constant volume T HT HTP The ECO dMEV may...

Страница 12: ...evel the fan will boost to high speed When the humidity drops below the selected level and after the selected period set on the timer the fan auto matically returns to trickle Case 2 Automatic operation as in case 1 with the facility to override the humidity sensor by means of an external switch fig 5 or light switch fig 4 when the humidity level in the room is lower than the selected level In this ...

Страница 13: ...o oper ate the boost when the humidity level is below the set point fig 6 When switching the pull cord off the fan will continue to operate on boost for the time set by the timer then will revert to trickle speed unless the hu midity level exceeds the set point MAINTENANCE IMPORTANT disconnect from the mains supply before carrying out any maintenance The ECO dMEV extract fan is supplied with a plas...

Страница 14: ...l ways recycle materials where possible please do not forget to deposit all packaging in the appro priate recycling bins If your device is also labeled with this symbol please take it to the nearest Waste Manage ment Plant at the end of its servicable life EnviroVent reserves the right to alter speci fications without notice ...

Страница 15: ...the fitting wiring instruc tions relevant guidance documents and by a competent and qualified person proof may be required please return the product to the place of purchase for a replacement Warranty Conditions Exclusions Please note that a receipt will be required as proof of purchase Fans bought from an unapproved source including but not limited to auc tion websites are not covered by the warran...

Страница 16: ...EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 info envirovent com www envirovent com Ref 9023025208 ...

Отзывы: