ECO dMEV LC

Содержание ECO dMEV LC

Страница 1: ...ECO dMEV LC ...

Страница 2: ...2 LJ D ...

Страница 3: ...3 LJ E 21 21 2 ...

Страница 4: ...4 LJ ...

Страница 5: ...5 Fig 3 J2 GND LS J1 LS N L 17V L N ECO dMEV LC KIT ECO dMEV LC CT 17 18 230Vac 50 60Hz CT 17 18 L N 230Vac 50 60Hz 0 17V DC ...

Страница 6: ...6 Fig 4 J2 GND LS J1 LS N L 17V KIT ECO dMEV LC CT 17 18 CT 17 18 230Vac 50 60Hz L N 230Vac 50 60Hz N L 0 17V DC ECO dMEV LC 230Vac 50 60Hz L N a b 230Vac 50 60Hz N L b a ...

Страница 7: ...7 Fig 5 L N J2 GND LS J1 LS N L 17V L N KIT ECO dMEV LC CT 17 18 230Vac 50 60Hz CT 17 18 230Vac 50 60Hz 0 17V DC ECO dMEV LC ...

Страница 8: ...persons with reduced physical sen sory or mental capabi lities or lack of expe rience and knowledge if they have been given supervisionorinstruc tion concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the applian ce Cleaning and user maintenance shall not be made by children without supervision INSTALLATION IMPORTANT Before installing and...

Страница 9: ...ERATION The ECO dMEV LC is an extractor fan designed to operate continuously at low speed adjustable with the facility to be set to high speed fixed through the following functions depending on the version an external switch live or light switch S T and HT versions the humidity sensor HT and HTP ver sions the internal pull cord switch HTP version or the PIR detector DT version The extractor can als...

Страница 10: ...s model is provided with an adjus table over run timer The selection of the run on time is done with the dip switches 6 and 7 setting between 1 5 15 and 30 mi nutes Factory setting 1 minute 1 Continuous operation The timer allows the fan to continue to ope rate in high speed for the selected period after the switch has been turned off Fig 4a Wiring diagram to boost the fan with the light switch Fi...

Страница 11: ...fig 4a or the light switch fig 4b when the humidity level in the room is lower than the selec ted level In this case the extrac tor operates in high speed for the selected period set on the timer after the light switch has been switched off and then goes back in low speed unless the humidity level exceeds the set point ATTENTION When the humidity rate is above the selected value the auto matic optio...

Страница 12: ...utomatica lly for 1 hour and then it keeps swit ched off during the set time for interval function This function causes the fan to run whatever the humidity level To select this function put the dip switch 1 to position ON To adjust the pre set time for interval function use the dip switches 2 and 3 Automatic operation with external switch to override the extractor The extractor is connected to th...

Страница 13: ...an is boosted to high speed during the selected pe riod set by the over run timer and then automatically returns to tric kle speed fig 3 2 Intermittent operation The unit starts automatically when a movement is detected and the unit continues to operate for the selected period set on the over run timer fig 3 FACTORY SETTINGS Interval function OFF Interval time 4h Humidity sensor 60 HR Timer 1 minute...

Страница 14: ...dicated Technical Team on 0345 27 27 810 PUTTING OUT OF SERVICE AND RECYCLING EEC legislation and our con sideration of future genera tions mean that we should al ways recycle materials where possible please do not forget to deposit all packaging in the appro priate recycling bins If your device is also labeled with this symbol please take it to the nearest Waste Manage ment Plant at the end of it...

Страница 15: ... the fitting wiring instruc tions relevant guidance documents and by a competent and qualified person proof may be required please return the product to the place of purchase for a replacement Warranty Conditions Exclusions Please note that a receipt will be required as proof of purchase Fans bought from an unapproved source including but not limited to auc tion websites are not covered by the warra...

Страница 16: ...EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 info envirovent com www envirovent com Ref 9023045204 ...