Cyclone 7
01423 859 395
SHOULD YOU ENCOUNTER ANY PROBLEMS
INSTALLING THIS UNIT, CALL US ON:
Safety
Read and understand these instructions before beginning
installation. The unit should be installed by a competent person.
Check there is space to fit the unit in your chosen location. As
standard it can be installed using 100mm or 125mm inside diameter
duct. With the optional adaptor, a 150mm duct can also be used.
The unit can be wall mounted as standard, or ceiling, recess, inline
and window mounted using optional kits (see page 15 for further
information). The unit cannot be wall mounted upside down (with the
electronic boards at the bottom) as this will void the warranty.
Ensure the operation of the unit does not affect the operation of open-
flue appliances. If you are unsure, please consult local regulations
or a qualified gas engineer. Consider the external cowl location in
relation to open-flues from appliances e.g. boilers. You must ensure
the cowl is positioned a minimum distance of 300mm away in all
directions.
In kitchens, if the unit is fitted above a cooker, it must be installed a
minimum distance of 1 metre above any hob, and not have a pullcord
fitted.
This unit is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities or lack of experience
and knowledge, unless they have been given supervision and usage
instruction by a person responsible for their safety.
Children should be supervised to ensure they do not play with the unit.
Cleaning and user maintenance must not be performed by children.