background image

18063 Rev E  06/17

(800) 234-4239

networketi.com

16 of 16

Environmental Technology, Inc.

Model EDH–4 Rev E Installation and Operation Manual

LIMITED WARRANTY

ETI’s two year limited warranty covering defects in workmanship and materials applies.  
Contact Customer Service for complete warranty information.

DISCLAIMER

Environmental Technology, Inc. makes no representations or warranties, either expressed or implied, with respect to the contents of this publication or the 
products that it describes, and 

specifically disclaims any implied warranties of merchantability or fitness for any particular purpose

. Environmental 

Technology, Inc. reserves the right to revise this publication and to make changes and improvements to the products described in this publication, without 
the obligation of Environmental Technology, Inc. to notify any person or organization of such revisions, changes or improvements. 

The ETI logo and We Manage Heat are registered trademarks of Environmental Technology, Inc. EDH is a trademark of Environmental Technology, Inc.

Copyright © 2014 Environmental Technology, Inc. All rights reserved.

SPECIFICATIONS

Operation

Dehydrator Type

Non-Programmable, Single Can-
ister, Desiccant Dehydrator

Regeneration Method

Manual Regeneration or Replacement

Regeneration Indication 

Desiccant Color Change and 
Compressor Run Time

Outlet Dew Point

-40°C (New or newly regenerated 
desiccant)  
to -10°C (Desiccant requiring 
regeneration or replacement)

Output Pressure

0.3 - 0.5 psig (34.5 mbar)

Flow Rate

6.0 scfh (2.8 lpm)

Capacity, Standard

18 scf (510 liters)

Capacity, Max

45 scf (1,274 liters)

Discharge port 

Single Port: 1/8" NPT Female 
(1/4" Hose Barb supplied)

Supply Voltage

100 – 240 VAC 50/60 Hz, Auto-select  

Power Requirement

@120 VAC: 22 watts maxi-
mum; 8.3 watts minimum

Reliability

MTBF: 100,000 hours

Interface

Air Pressure Indication 

Digital Display (English or SI)

Data Display 

Pressure, Estimated Desiccant 
Capacity Remaining, Error Codes

Communications Port

Alarm Relay

Alarm Relay Capacity

2 Amp @ 30 VDC

Relay Connection

6-position terminal block

Enclosure

Dimensions

5.22" ×  11.63" × 7.0" 
(133 mm × 295 mm × 178 mm)

Weight

7.8 pounds (3.54 kg)

Mounting

19" or 13 1/2" Rack (3U space re-
quired), wall mount, shelf or table top

Environmental

Storage Temp

-40°C to 60°C

Operating Temp

0°C to 55°C 

ORDERING INFORMATION

Order Number

Description

18021

EDH–4 Low Cost Air Dehydrator (Revision A)

25016

Replacement Desiccant Canister with Desiccant for EDH-4 (Revision A)

18138

Replacement Desiccant, 32 ounces (0.95 liters)

















Содержание EDH-4

Страница 1: ...e Manage Heat MANUAL Low Cost Air Dehydrator MODEL EDH 4 Environmental Technology Inc 1850 N Sheridan Street South Bend IN 46628 574 233 1202 Fax 574 233 2152 Toll Free 800 234 4239 Fax 888 234 4238 w...

Страница 2: ...ehydrator are capable of generating as much as 1 2 psig 82 7 mbar Proper safety practice requires treating all pneumatic components with care Operating Temperature Verify adequate air flow and power s...

Страница 3: ...Additional Equipment Required for Installation 6 Initial Inspection 6 Location of Installation 6 Mounting the EDH 4 7 Preparation and System Set up 8 Principal Considerations 8 Power Connection 8 Pne...

Страница 4: ...into the transmitter from the antenna when the antenna is not tuned properly Water in the transmis sion line will de tune the antenna and cause a higher VSWR PART NUMBER DESCRIPTION 18138 Desiccant ED...

Страница 5: ...itions reduce system performance Description The EDH 4 Air Dehydrator is an economical manually regenerative air dehydrator for waveguide envi ronments Air is pressurized by a twin head vibratory pump...

Страница 6: ...procedure Defective operation to test effective operation 1 Attach power to the EDH 4 2 Seal outlet plug thumb or kink in hose 3 Pump stops 4 LED display reads between 30 and 50 5 Remove seal LED disp...

Страница 7: ...least 5 pounds 2 4 kg The locations of the mounting points are shown in Figure 3A Narrow and Figure 3B Wide 5 22 132 6mm 13 63 346 1mm 12 63 320 7mm 2 25 57 2mm 4 81 122 2mm 7 00 177 8mm 19 00 483mm 1...

Страница 8: ...recommended to account for this buildup Power Connection The EDH 4 uses a universal 100 VAC to 240 VAC at 50 60 Hz power supply This eliminates the need to set voltage during the installation or havi...

Страница 9: ...re in SI units is 99 mbar displayed as 99 the decimal point displayed to the lower right of the numerals indicates mbar mode To assess the Percentage Desiccant Absorption Capacity remaining quickly pr...

Страница 10: ...replace or regenerate the desiccant This alarm is reset by depressing MODE during power up Both relays close at power off Table 2 near right Alarm Relay Connector Pin Assignments Figure 7 far right E...

Страница 11: ...en recorded a Change Desiccant two letter error code CD on the front panel display is issued to indicate a need to regenerate or replace the desiccant PRESSURE SOUTH BEND INDIANA U S A www networketi...

Страница 12: ...ote Servicing should be performed by qualified personnel The desiccant used in the EDH 4 Dehydrator is known as an indicating silica gel Care should be taken to prevent the dust from entering the resp...

Страница 13: ...ottle on the EDH 4 is accessible below the top panel The steps are 1 Remove power and vent system of pressurized air 2 Remove four 4 attachment screws from top panel Fig 11 lift and remove top panel 3...

Страница 14: ...ube under control panel wiring Brown tube to Pump Pump Brown tube to Pump When reinserting the desiccant bottle into the EDH 4 note the mark next to the nozzle on the bottom of the bottle This mark in...

Страница 15: ...PRESSURE LED display If the silica particles are white renew the desiccant Refer to the Maintenance section of this manual HF Low Temperature Verify that the electronic enclosure temperature is above...

Страница 16: ...Type Non Programmable Single Can ister Desiccant Dehydrator Regeneration Method Manual Regeneration or Replacement Regeneration Indication Desiccant Color Change and Compressor Run Time Outlet Dew Poi...

Отзывы: