Local Standards

The installation shall conform to the Plumbing Code of Australia (PCA). The following standards and regulations must be taken into account when 

planning the installation of the Enviroheat water heater system.

•  AS/NZS 3500.4.2 Notational plumbing and drainage code hot water supply systems – acceptable solutions. 
•  HB 263-2004 heated water systems plumbing industry commission.
•  AS/NZS 3000 Electrical installations (known as the Australian/New Zealand Wiring  Rules).
•  Any local regulations that govern this type of installation.
•  In frost prone areas  

Where these instructions and any local regulations are in confl ict, the local regulations shall prevail.

Safety

Do not commence any aspect of this installation until you have satisfi ed yourself that all safety issues have been addressed.

Exclamation-triangle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

THIS APPLIANCE MAY DELIVER WATER AT HIGH TEMPERATURE. REFER TO THE PLUMBING

CODE OF AUSTRALIA (PCA), LOCAL REQUIREMENTS AND INSTALLATION INSTRUCTIONS TO DETERMINE IF

ADDITIONAL DELIVERY TEMPERATURE CONTROL IS REQUIRED

This installation should only be performed by an approved professional with suitable experience and licenses, authorised 

by Southern Cross Water Heating Pty Ltd to conduct the work.

It is imperative that installers adhere to Occupational Health and Safety Guidelines at all times. The installer is responsible for their safety and the 

safety of those around them.

Water Quality

Water supply from an unfi ltered water source that may be highly conductive or have a high mineral content may void the system warranty.

Therefore, to ensure water quality guidelines are met, the following characteristics should not be exceeded.

Water Properties

Acceptable Levels

Total hardness

200 mg/litre or ppm

Total Dissolved Solids (TDS)

600 mg/litre or ppm

Chloride

250 mg/litre or ppm

Magnesium

10 mg/litre or ppm

Sodium

150 mg/litre or ppm

pH

Min 6.5 to Max 8 .5

Electrical conductivity

850 μS/cm

In areas of poor water quality, it is recommended that a softener, conditioner or similar device be fi tted to the water supply. 

Exclamation-triangle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

A  breach  of  this  condition  may  void  the  warranty  in  the  event  of  damage  caused  by  water  quality  exceeding  these 

characteristics.

Supplementary Heat Sources

If a supplementary heat source is connected to the storage tank, the maximum energy input cannot be more than 10 kW, including the electrical 

element. Where greater input is required, a pressure and temperature relief valve with a higher kW rating is to be fi tted to the storage tank

.

Where stove coils are used for supplementary heating the water must be connected in an open vented manner. Refer to Australian Standard AS3500 

for more details on acceptable connection solutions.

UserManual_2021-Enviroheat.indd   9

UserManual_2021-Enviroheat.indd   9

1/09/2021   11:47:39 PM

1/09/2021   11:47:39 PM

Содержание 200EH1-14

Страница 1: ... O H E A T H e a t P u m p W a t e r H e a t e r O w n e r s M a n u a l Models 200EH1 14 250EH1 15 UserManual_2021 Enviroheat indd 1 UserManual_2021 Enviroheat indd 1 1 09 2021 11 47 37 PM 1 09 2021 11 47 37 PM ...

Страница 2: ...ortant Safety Information 10 ELECTRICAL CONNECTIONS 11 Electrical Protection Precautions 11 COMMISSIONING CHECK LIST 11 OPERATION AND FUNCTIONS 12 Display 12 Screen lock function 13 Emergency mode 13 How to set the timer 13 Recommended system settings 13 TROUBLESHOOTING 14 Hot water use higher than anticipated 14 Water discharge through the pressure relief valve 14 MAINTENANCE 15 Draining and flus...

Страница 3: ...ermostat and over temperature cut out in the circuit This appliance contains fluorinated greenhouse gases R134a 0 9kg Fluorinated greenhouse gases are contained in hermetically sealed equipment Global Warming Potential 100 years GWP100 1 430 EXCLAMATION CIRCLE CAUTION Personally inspecting or servicing any part of the system is not recommended The water heater shall not be installed at places wher...

Страница 4: ...e Rankine Cycle has been used for over a century for refrigeration and air conditioning applications and has been used for energy efficient water heating for decades 1kW electricity combinedwith 3kWofFREE heatfrom theair 4kW forwater heating HOWITWORKS Tounderstandtheconceptof heatpumps imaginearefrigerator workinginreverse While a refrigerator removes heat from an enclosed box and expels that hea...

Страница 5: ... range with heater 35 C 75 C 35 C 75 C Max working pressure of refrigerant 0 8 2 8MPa 0 8 2 8MPa Refrigerant type weight R134a 0 9kg R134a 0 9kg Sound power level 57dB 58dB STC Zone Zone 1 4 Zone 1 5 Ambient temp operating range of heat pump 7 45 C 1 7 45 C 1 Water inlet and outlet connection G3 4 F G3 4 F Safety valve connection G3 4 F G3 4 F Drain Water inlet connection G3 4 F G3 4 F Product Dim...

Страница 6: ...rain Outlet HotWater Outlet AirOutlet AirInlet SafetyValve Condensate Outlet B C D A Model A B C D 200EH1 14 629 270 980 1 692 250EH1 15 629 270 1275 1 987 UserManual_2021 Enviroheat indd 6 UserManual_2021 Enviroheat indd 6 1 09 2021 11 47 39 PM 1 09 2021 11 47 39 PM ...

Страница 7: ...erence present that may affect control systems Ensure that there are no corrosive gases or liquids present near the unit Where ambient temperatures are likely to drop below 0 C ensure that adequate freeze protection is provided EXCLAMATION CIRCLE CAUTION Keep an adequate distance between the water heater and bedrooms Your Enviroheat system emits very low noise level however there are certain times...

Страница 8: ...Page 8 of 20 rev 01 09 21 Installation Dimensions 50mm AirOutlet AirInlet Display 400mm UserManual_2021 Enviroheat indd 8 UserManual_2021 Enviroheat indd 8 1 09 2021 11 47 39 PM 1 09 2021 11 47 39 PM ...

Страница 9: ...idelines at all times The installer is responsible for their safety and the safety of those around them Water Quality Water supply from an unfiltered water source that may be highly conductive or have a high mineral content may void the system warranty Therefore to ensure water quality guidelines are met the following characteristics should not be exceeded Water Properties Acceptable Levels Total ...

Страница 10: ...toasafelocation terminatingabovethegroundlevel Pleaseensure that the drain is installed in a place where it cannot be affected by freezing conditions per AS3500 Cold Water Expansion Relief Valve Fit the 600 kPa pressure relief valve in the cold water supply pipe after the check valve stop cock and if required pressure limiting valve Important Safety Information All water heaters have the ability t...

Страница 11: ...tion is free from any corrosive materials or chemicals F The location is free from any excessive dust or material that can become airborne Water System Piping F Temperature and pressure relief valve PTR is properly installed with a discharge pipe plumbed to suitable drain F Check that all plumbing connections including piping valves and fittings are properly installed and free of leaks F The syste...

Страница 12: ...ode recommended setting In this mode the unit will run during programmed periods for example between 5am and 9pm This mode is essential if you have solar power installed in order to maximize free energy utilization See section on recommended settings Holiday mode If you are planning to be on holiday you can set your system to turn on the day before you are due to return Select this mode and use th...

Страница 13: ...resent danger and will void warranty How to set the timer Step 1 Press the TIMER button and use the to set the time of day hours Press the TIMER button again button the time of day minutes After 10 seconds the screen will revert to RUN mode Step 2 With the unit on press the MODE button to select ECO mode Step 3 Press SET to select L1 timer START time Use the to set the start time hours Press SET a...

Страница 14: ...ce if necessary Water discharge through the pressure relief valve All Enviroheat heat pump water heaters have two pressure valves located within the system configuration The cold water expansion control valve ECV located in the cold water supply pipe may release a small amount of water from time to time during the heating cycle of the system The water discharge is water expanding due to the heatin...

Страница 15: ...o drain away from the tank 6 Manually open the pressure temperature relief valve which will allow air into the tank and the water within the tank will flow out via the flexible drain pipe fitted to the cold inlet connection Hold the valve open until the tank is empty Relief valves wrench The lever on the relief valves should be operated at least every six months Failure to do so may result in fail...

Страница 16: ...tralia Consolidated Energy For after sales service 1300 560 944 For sales or new product 1300 560 944 info consolidatedenergy com au www enviroheatpump com Head Office Consolidated Energy 11 Cressall Road Balcatta WA 6021 UserManual_2021 Enviroheat indd 16 UserManual_2021 Enviroheat indd 16 1 09 2021 11 47 41 PM 1 09 2021 11 47 41 PM ...

Страница 17: ...the installation instructions or installed such that normal service access is difficult a service charge may apply If at the discretion of the attending service person access with is assessed as dangerous service will be refused Any work required to gain reasonable access to the appliance will be chargeable to the customer by the attending service person including but not limited to removal of cup...

Страница 18: ...s to repair the Product other than by an Enviroheat Dealer or approved service personnel 3 Failuretoinstall commission service repairandremovetheProductinaccordancewiththemanufacturer sinstallationinstructions current AS NZS 3000 AS NZS 3500 AS NZS 5601 local regulations and municipal building codes by persons authorised to do so 4 Failure due to use of parts other than Enviroheat branded approved...

Страница 19: ...s commercialtermsandconditionsandbytheapplicableOH Slegislation Eachperson that installs assembles or services must comply with all OH S requirements relevant to the type of work being conducted including but not limited to plumbing work work on heights exceeding 2 5m and electrical work The customer must ensure that it complies with all its OH S obligations This warranty will be void if these con...

Страница 20: ...the address below and the pink copy to the Dealer Installer Consolidated Energy ABN 85 124 564 361 11 Cressall Road Balcatta WA 6021 Owners Name Installation Address Suburb State Telephone Home Work Email Date System Model Number Tank Serial Number Installers Name Installers Address Installers Telephone Comments Customer Signature Installer Signature Date UserManual_2021 Enviroheat indd 20 UserMan...