Look through the hole and make sure there are no kinks or twists in the 
ducting.  Pull the ceiling box down through the hole in the ceiling.  While 
holding it in place, install a 1-3/8” drywall screw through the drywall into the 
flange of the ceiling box on each side to temporarily hold the box in place.   
Remove ceiling grill and screws from its packaging.  Center the grill over the 
ceiling box.  Install the grill with the white screws provided by screwing 
through the flange of the ceiling box.  Some ceiling surfaces are uneven and 
may cause a small gap to be present.  This can easily be caulked later if 
excessive. 

Repeat these steps at each location 

Return to the attic and go to each location.  Using the nylon straps and the pan 
head screws provided, support the duct to the framing.  Make sure the motor 
head is still level and the dampers still close naturally.  This will stabilize the 
entire assembly.  Replace any insulation that was removed.  

Repeat these steps at each location 

VERY IMPORTANT!  

Remove the shipping tape from the back draft 

dampers. Make sure the dampers will open and close easily and without 
obstruction.  

Repeat these steps at each location 

Once all of the QuietCool fans are hung, it’s time to go below and install the 
ceiling box and ceiling grill at each intake location. 

8.

9.

10.

11.

12.

13.

14.

The installation is now complete except for the electrical work necessary to 
make them operate. The electrical wiring for the fan requires a 120 volt three 
prong outlet within 6 feet of the motor head in the attic.  

The outlet should be wired to and controlled by a two-gang or three-gang box 
installed in the hallway wall with a timer and switch for each fan.  

VERY IMPORTANT!   M

ake sure the fan blade spins freely. This is very 

important to system operation.   

!

!

Содержание EC-3040

Страница 1: ...ation Manual EnviroCool TM The Fresh Air Conditioning System Read carefully all of this manual prior to installing the unit Model EC 4824 Horizontal Model EC 3040 Vertical The natural choice for energy savings ...

Страница 2: ...he pathway of the moving air from the EnviroCool to each QuietCool fan will be cooled effectively Those rooms not in the pathway may not achieve satisfactory comfort levels To overcome this problem additional EnviroCools can be added to these rooms if required LAYOUT RULES 1 Each EnviroCool must be installed in an exterior wall It should be on the lower floor of a multi story home 2 The best layou...

Страница 3: ...500 2 4 1 7 14 sq ft 2 500 3 000 2 5 1 8 16 sq ft 3 000 3 500 2 6 1 9 18 sq ft 3 500 4 000 2 4 2 10 20 sq ft 4 000 4 500 3 5 2 11 22 sq ft 4 500 5 000 3 4 3 13 26 sq ft 5 000 5 500 3 5 3 14 28 sq ft 5 500 6 000 3 6 3 15 30 sq ft Total fans equal to one QC 1500 ie one QC4500 QC 1500 fans Homes with vaulted ceilings in main area ad 1 25 percent to entire home size i e 2 000 sq ft x 1 25 2 500 sq ft ...

Страница 4: ... Master Bedroom Bedroom Bedroom Patio Family Room Living Room Dining Room Kitchen Garage Bath Patio Bath Bedroom EC EC QC QC QC QC QC G 4 QC G QC EnviroCool QC 1500 Fan QC 4500 Fan EC Legend Air movemet Air direction QC fan air intake when used with open windows UP ...

Страница 5: ...e and outside before making a final selection Make sure from the outside wall that the unit is high enough that the bottom will not touch the ground and the top won t stick above the window if placed under window Usually 36 inches is needed from window to ground level for horizontal CLEARANCES around ROUGH OPENING sides top bottom Exterior 2 4 6 Interior 1 1 1 Make a cutout template out of cardboa...

Страница 6: ... Apply duct tape completely around the opening on both the inside and outside Install the duct tape by allowing of the width of the tape to be on the coroplast in the opening and the other half of the tape is then folded over onto the inside and outside walls Locate and fasten the main frame to the outer wall using 3 10 x 2 screws on each side that will go through the exterior wall and into each s...

Страница 7: ...ake sure all water is returning into the water pan and that there is no water dripping anywhere Unplug pump from receptacle plug Appliance Module into receptacle and then plug pump into bottom of Appliance Module This remote module will receive it s on and off signals from the remote mounted thermostat and control box Install the exterior housing Hold in place with 2 10 x 5 8 self drilling sheet m...

Страница 8: ...rill that will be installed later is larger than the template While holding the template in place mark around it with a pencil Using a drywall saw or similar device cut out the hole Repeat these steps at each location Open and unpack each QuietCool fans Make sure all parts are present Most of the system comes pre assembled The main assembly should be put up in the attic through the crawl hole and ...

Страница 9: ...g Make sure the motor head is still level and the dampers still close naturally This will stabilize the entire assembly Replace any insulation that was removed Repeat these steps at each location VERY IMPORTANT Remove the shipping tape from the back draft dampers Make sure the dampers will open and close easily and without obstruction Repeat these steps at each location Once all of the QuietCool f...

Страница 10: ...ptacles 3 wire with ground Romex cable Junction Box QuietCool Control Box 72 Black Black White Green Red Yellow Orange Cooler Control Timer 2Sw itch 3 S w i t c h Line Load Red Black Black 3 wire with ground Romex cable Red Black White Green Red Red Black White Green Green White Green Black QC4500 Fan Receptacles One Gang Box 3 wire with ground Romex cable 2 wire with ground Romex cable Cap off On...

Страница 11: ...ent Unit Water Shut Off Valve Connection Box Connection Box Cover Water Filter Overflow Outlet Water Pump Float and Valve Assembly Water Reservoir Insect Screen Water Feed Tube Water Distributor Pipe Splash Guard Remote Module EC 3040 Vertical EC 14005 EC 50080V EC 60050 V EC 60060 V EC 60020 V AC 45100 AC 21000 AC 21020 EC 20020 EC 21000 EC 20025 EC 20010 EC 13200 EC 60040 V EC 50035 V EC 60030 V...

Страница 12: ...Manufactured by 12 Rev 9 08 The Whisper Quiet Whole House Fan System QC 1500 fan QC 4500 fan EC 3040 vertical EnviroCool EC 4824 horizontal EnviroCool ...

Отзывы: