07-02317C EB AV 

EnviroBoss 

Electrical safety devices

 

Circuit breaker:

 If the circuit breaker detects overload or short 

circuit conditions, the breaker will automatically shut off the 
electrical supply. If this should occur, check the power cable 
carefully for any damage and ensure it is plugged into a properly 
grounded outlet. Press the Circuit Breaker Reset Switch (Fig. A) 
to reestablish the electrical supply.  

TRANSPORT AND STORAGE 

Always use the handle to load or carry the unit.  

For cord storage, wrap cord around housing in groove. Pull cord 
snug and secure with plug clip (Fig. A).  

Units may be stacked up to five high for transport and storage 
(Fig. C). To stack, tip first unit back onto its outlet side and nest 
additional units on top (Fig. A).  

When transporting, secure the unit(s) carefully to prevent sliding 
and damage to the unit and/or injury to vehicle occupants.  

Keep unit dry. Do not expose the unit to rain or snow.  

MAINTENANCE 

WARNING:

 Unplug unit before performing any maintenance. 

Before each use 

Inspect the power cord. If cord is damaged, do not use. Always 
grasp the plug (not the cord) to unplug. 

As needed  

Clean housing and impeller. If dust accumulation is visible in the 
interior, remove the four screws from the outlet grill as shown 
(Fig. B). Clean impeller assembly and all surfaces with 
pressurized air and/or with a soft cloth. Do not apply liquids to 
the impeller assembly. The housing may be cleaned with a mild 
solution of detergent and warm water. Ensure housing is 
completely dry before reassembling. 

WARNING: This product and other substances that may 
become airborne from its use contain chemicals, 

including lead and phthalates, known to the State of California to 
cause cancer, birth defects, or other reproductive harm. For 
more information, go to P65Warnings.ca.gov 

FOR SERVICE CALL YOUR LOCAL DISTRIBUTOR or 
EnviroBoss at 800-932-3030. www.EnviroBoss.com 

SPECIFICATIONS 

Model  

EB AV  

Air movement 

2600 CFM | 4417 CMH 

Static pressure (H

2

O) 

0.40 in. | 99 Pa  

Units per 15 amp 
circuit 

Up to 4 

Dimensions  
(D × W × H) 

10.8 × 24.3 × 24.0 in. 
27.4 × 61.7 × 61.0 cm 

Weight 

27.5 lbs. | 12.5 kg 

Amps 

2.7A  

Volts 

115V 

Frequency 

60 Hz 

Power (motor rating) 

0.46 hp / 340W 

Sound level (avg.) 

58

–72 dB 

Control 

Variable speed rotary switch 

Cord length 

15 ft. | 4.6 m 

Construction 

Rotomolded polyethylene and injection 
molded ABS housing components; steel 
wire inlet and outlet grills.  

Safety 

ETL tested to UL and CSA standards 

Specifications are subject to change without notice. Some values  
may be approximate. 

 

  

 

 

Fig. B: Disassembly for cleaning

 

Remove the four screws as shown and lift off the front assembly. 
Retain screws for reassembly. Do not overtighten screws.  

Fig. C: Stacking for storage or transport

 