07-02317C EB AV
2
EnviroBoss
Electrical safety devices
Circuit breaker:
If the circuit breaker detects overload or short
circuit conditions, the breaker will automatically shut off the
electrical supply. If this should occur, check the power cable
carefully for any damage and ensure it is plugged into a properly
grounded outlet. Press the Circuit Breaker Reset Switch (Fig. A)
to reestablish the electrical supply.
TRANSPORT AND STORAGE
Always use the handle to load or carry the unit.
For cord storage, wrap cord around housing in groove. Pull cord
snug and secure with plug clip (Fig. A).
Units may be stacked up to five high for transport and storage
(Fig. C). To stack, tip first unit back onto its outlet side and nest
additional units on top (Fig. A).
When transporting, secure the unit(s) carefully to prevent sliding
and damage to the unit and/or injury to vehicle occupants.
Keep unit dry. Do not expose the unit to rain or snow.
MAINTENANCE
WARNING:
Unplug unit before performing any maintenance.
Before each use
Inspect the power cord. If cord is damaged, do not use. Always
grasp the plug (not the cord) to unplug.
As needed
Clean housing and impeller. If dust accumulation is visible in the
interior, remove the four screws from the outlet grill as shown
(Fig. B). Clean impeller assembly and all surfaces with
pressurized air and/or with a soft cloth. Do not apply liquids to
the impeller assembly. The housing may be cleaned with a mild
solution of detergent and warm water. Ensure housing is
completely dry before reassembling.
WARNING: This product and other substances that may
become airborne from its use contain chemicals,
including lead and phthalates, known to the State of California to
cause cancer, birth defects, or other reproductive harm. For
more information, go to P65Warnings.ca.gov
FOR SERVICE CALL YOUR LOCAL DISTRIBUTOR or
EnviroBoss at 800-932-3030. www.EnviroBoss.com
SPECIFICATIONS
Model
EB AV
Air movement
2600 CFM | 4417 CMH
Static pressure (H
2
O)
0.40 in. | 99 Pa
Units per 15 amp
circuit
Up to 4
Dimensions
(D × W × H)
10.8 × 24.3 × 24.0 in.
27.4 × 61.7 × 61.0 cm
Weight
27.5 lbs. | 12.5 kg
Amps
2.7A
Volts
115V
Frequency
60 Hz
Power (motor rating)
0.46 hp / 340W
Sound level (avg.)
58
–72 dB
Control
Variable speed rotary switch
Cord length
15 ft. | 4.6 m
Construction
Rotomolded polyethylene and injection
molded ABS housing components; steel
wire inlet and outlet grills.
Safety
ETL tested to UL and CSA standards
Specifications are subject to change without notice. Some values
may be approximate.
Fig. B: Disassembly for cleaning
Remove the four screws as shown and lift off the front assembly.
Retain screws for reassembly. Do not overtighten screws.
Fig. C: Stacking for storage or transport