background image

INTRODUCTION

Thank you for your recent EnviroAire IAQ Power EA-755 
humidifier purchase. We appreciate your business and are 
pleased to add your name to our growing list of customers. 
You have invested in the highest quality equipment available. 
EnviroAire IAQ manufactures whole-home indoor air quality 
products and is a recognized leader in the indoor air quality 
industry.

Your humidifier will require periodic maintenance to assure 
continued performance. 

 Please take a few minutes and read this manual. This will 
familiarize you with the benefits you will receive from the 
equipment you just purchased and help you understand the 
routine maintenance that will be required. 

If you have questions regarding your humidifier, your may 
reach out to us at www.enviroaireiaq.com/contact-us, or 
contact the EnviroAire IAQ certified partner who installed 
your system.

 

†

 WARNING

   120 volts may cause injury from electrical 

shock. Disconnect power and shut off water 

supply before servicing.

 

†

CAUTION

 

Sudden operation may cause personal injury 

or property damage. Turn the EnviroAire IAQ 

humidifier control to “OFF” or lowest setting 

before servicing.

EnviroAire IAQ Replacement Water Panel evaporators are 
available from your installing contractor. Use the dealer 
locator in our web site (www.enviroaireiaq.com/find-a-pro). 
Purchase only EnviroAire IAQ Water Panels to maintain 
peak performance.

PRINCIPLE OF OPERATION

With your purchase of this humidification system, you have 
invested in a humidifier that operates on the evaporative 
principle – nature’s own way of adding moisture – providing 
optimum relative humidity (RH) throughout the heating 
season. It is very possible that you have questions concerning 
your new humidifier – questions on what it can do for you, 
and what you should do to receive maximum benefits from it. 

Nature, in producing an invigorating comfortable spring 
day,  combines just the right temperature and the right 
amount of moisture. EnviroAire IAQ humidifiers employ the 
same principle, with refinements, to give you the optimum 
RH for maximum allowable comfort all winter long.

The important considerations in the evaluation of a 
humidifier are precise control, sufficient capacity, trouble-
free performance and minimum maintenance. The operating 
principle of your EnviroAire IAQ humidifier provides all of 
these advantages. Here, briefly, is the method: the EnviroAire 
IAQ humidifier is installed to operate in conjunction with the 
heating, ventilating, air conditioning equipment (HVAC) 
blower. When the EnviroAire IAQ Humidifier Control calls 
for humidity and the blower motor is operating, water flows 
to the distribution tray located at the top of the humidifier. 
The water is uniformly distributed across the width of the tray 

and through a scientifically designed system of outlets. It flows 
by gravity over the water panel evaporator, the heart of the 
humidifier. Dry, hot air is moved through the moisture-laden 
water panel evaporator where natural evaporation takes 
place. The now-humidified air carrying moisture in vapor form 
(nature’s own way) is circulated throughout the home. Power 
model EA-755 has a built-in fan which draws air through the 
water panel. 

The correct water flow is determined by an orifice 

provided with each drain type humidifier. When 

the humidifier is operating, there will be a small, 

steady stream of water to drain, which flushes 

away most of the trouble-causing minerals.

Do not use the saddle valve to regulate the water 

flow. It is designed to be completely open or closed. 

The minerals and solid residue not trapped by the replaceable 
water panel evaporator are flushed down the drain in the 
EA-755 model. This is the most effective and least expensive 
method to dispose of trouble-causing minerals. The drain 
also eliminates the problems caused by stagnant water. 

Содержание Power EA-755

Страница 1: ...Power EA 755 Humidifier Power Model EA 755 Humidifier Owner s Manual ...

Страница 2: ...its from it Nature in producing an invigorating comfortable spring day combines just the right temperature and the right amount of moisture EnviroAire IAQ humidifiers employ the same principle with refinements to give you the optimum RH for maximum allowable comfort all winter long The important considerations in the evaluation of a humidifier are precise control sufficient capacity trouble free p...

Страница 3: ...level inside the cold air return duct RH is a measure of the amount of moisture in the air as a percentage of what the air can hold Warm air can hold more moisture than cold air can The control has lights which indicate humidifier operation when the Water panel needs to be replaced and when service is required See Operating Instructions for more information There are many humidifiers on the market...

Страница 4: ...on minor adjustments may be necessary This is dependent upon your home s construction Refer to TABLE 3 Operation Guide on the following page The RH in your home will now be accurately controlled to meet your needs and should not need further adjustment during future heating seasons Make note of the dial setting in the event you temporarily move the knob to OFF when performing annual maintenance of...

Страница 5: ...e timer TEST RESET The Test Reset feature allows the humidifier operation to be checked even if there is no call for humidity See Check the Humidifier Operation ADDITIONAL INFORMATION Your humidifier is a precision system that will accurately maintain the RH in your home For every 2 F change in outdoor temperature the Digital Humidifier Control will automatically adjust the indoor RH by 1 The Digi...

Страница 6: ...ccasion indoor moisture producing activities such as clothes drying cooking showers etc may raise the RH level higher than it should be even though the EnviroAire IAQ humidifier is not operating Telltale indications are condensation or frost on cold surfaces such as windows doors walls etc If such condensation persists for several hours your home should be ventilated to dissipate the potentially d...

Страница 7: ...efore servicing 1 Note Humidifier Control setting and turn dial to the OFF position 2 Disconnect electrical power and turn off water supply 3 Unlatch humidifier front cover assembly 1 from base assembly 2 at the bottom of the cover lift and set aside 4 Pull out the Water Panel evaporative assembly 3 by grasping at the top and tipping out 5 Unsnap the distribution tray 4 from the scale control inse...

Страница 8: ...ter than thirty 30 days after said five 5 year period by you to your original supplier together with the model number and installation date of the humidifier THIS WARRANTY SHALL NOT OBLIGATE ENVIROAIRE IAQ FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE HUMIDIFIER ITSELF IMPLIED WARRANTIES OF MERCHANTABILITY...

Отзывы: