15
Maintenance And Service
Figure 15: Ignitor assembly beside
the burner�
12. Relight the pilot and confirm the flame properly covers both the thermocouple and thermopile (see
Figure 64 on page 39)
.
Should the pilot require adjustment, turn the adjustment screw (Figure
49 on page 34) clockwise to increase or counterclockwise to decrease until the correct flame is
achieved.
13.
Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition, operation
and proper flame appearance. Confirm the inlet and manifold pressures are within the acceptable
ranges as directed in section
I
ntIal
I
ntallatIon
- G
as
l
Ine
c
onnectIon
and
t
estInG
.
If the Westport has
been installed at an altitude higher than 2000ft (610m) it is required to de-rate the unit accordingly:
In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas
Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at
elevations above 2000 (610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level.
Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate
guidelines.
In Canada
: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high
altitude rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).
14. MAKE SURE that the conversion label is installed on or close to the rating label to signify that the
unit has been converted to a different fuel type.
Содержание Westport Steel
Страница 45: ...45 Notes...
Страница 46: ...46 Notes...