OWNER’S MANUAL

50-1033

WARNING: 

 If the information in this manual is not followed exactly, a 

fire or explosion may result causing property damage, personal injury 

or loss of life. Installation and service must be performed by a qualified 

installer, service agency or the gas supplier.

  Version Française: www.enviro.com/fr.html

W

AR

RA

NT

Y R

EG

ISTR

AT

IO

N

enviro.com/warranty

Westport - Cast

F R E E S T A N D I N G   G A S   F I R E P L A C E

C#4001609

CERTIFIED TO: ANSI Z21.88 / CSA 2.33 VENTED GAS FIREPLACE HEATERS

CSA 2.17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

Содержание Westport-Cast

Страница 1: ...and service must be performed by a qualified installer service agency or the gas supplier Version Fran aise www enviro com fr html W A R R A N T Y R E G I S T R A T I O N e n v i r o c o m w a r r a...

Страница 2: ...ll your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali...

Страница 3: ...ormed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the...

Страница 4: ...s 12 Glass Door Removal 12 Fuel Conversion 13 Initial Installation 16 Preparation For Installation 16 Clearances to Combustibles 16 Planning Your Installation 16 Vent Termination Restrictions 18 Vent...

Страница 5: ...allation of Optional Blower 35 Installation of Log Set and Embers 35 Installation of Panel Set 38 Installation of Safety Screen 39 Trouble Shooting 40 Parts List Cast 41 Parts List Components 42 Parts...

Страница 6: ...D TO ANSI Z21 88 CSA 2 33 VENTED GAS FIREPLACE HEATERS CSA 2 17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P 4 1 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO WESTPORT Fireplac...

Страница 7: ...flue REAR VENT 23 59 7 cm Figure 1 Westport Exterior Dimensions Rating Label Location The Rating Label is located on a plate hang on the back left of the unit WARNING Operation of this heater when not...

Страница 8: ...knob counter clockwise to the ON position Flip the burner switch to ON then turn the HI LOW knob to the desired setting 10 Close the front control panel 11 Turn on all electric power to the appliance...

Страница 9: ...fireplace to be adjusted in order to accommodate different climates and venting arrangements Start the pilot and then the burner Make sure the pilot flame is burning normally and none of the burner p...

Страница 10: ...the fan control knob To turn the blower off turn the knob COUNTER CLOCKWISE until it clicks off It is advisable not to operate the blower below 1 3 speed as it puts a strain on the windings of the bl...

Страница 11: ...eed cleaning about two weeks after installation Use a mild glass cleaner and a soft cloth abrasive cleaners will damage the glass and plated surfaces Depending on the amount of use the glass should re...

Страница 12: ...door and remove the glass carefully Install the new piece of glass with the large bulb in the gasket tape against the unit Place the joint in the tape in a bottom corner Close door Glass Door Removal...

Страница 13: ...odes and requirements of the authority having jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing propert...

Страница 14: ...y the short side f Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible refer to Figure 14 If the conversion is from LPG to NG the red o ring of t...

Страница 15: ...port has been installed at an altitude higher than 2000ft 610m it is required to de rate the unit accordingly In the USA The appliance may be installed at higher altitudes Please refer to your America...

Страница 16: ...lling on a carpeted surfaces a non combustible hearth pad must be used Minimum Alcove Dimensions Width 48 inches 121 9 cm Height 60 inches 152 4 cm Depth max 24 inches 60 96 cm CLEARANCES MUST BE SUFF...

Страница 17: ...e 23 If a 90 elbow is used in the horizontal plane 36 91 4 cm must be subtracted from the allowable horizontal run There are three 3 basic types of Direct Vent System installations The three 3 types o...

Страница 18: ...ed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft 60 cm from center line of terminal E 18 in 45 cm...

Страница 19: ...steep up to 12 12 roof 46DVA FF Flat flashing 46DVA VCH High wind vertical termination 4DHCS 4DT HC 46DVA HC High wind horizontal termination 4DT HKA 4DT HKB 46DVA KHC Horizontal termination kit 4DT...

Страница 20: ...cceptable Having the fewest number of elbows is ideal as they tend to disrupt air movement Using 45 elbows is preferable to using 90 elbows Also a shorter vent system will perform better than a longer...

Страница 21: ...l being penetrated is constructed of non combustible material i e masonry or concrete a 7 17 8cm hole is acceptable 4 Position the horizontal vent termination in the center of the 10 25 4cm x 10 25 4c...

Страница 22: ...he vinyl siding standoff prevents excessive heat from possibly melting the vinyl siding material Note that the horizontal vent termination bolts onto the flat portion of the vinyl siding standoff shad...

Страница 23: ...Figure 29 Tighten the clamp around the pipe section Use a level to make sure the pipe is truly vertical With roofing nails secure the support straps to the roof Seal the nails holes heads with non har...

Страница 24: ...12 3 25 0 99 Over 11 12 to 12 12 4 1 22 Over 12 12 to 14 12 5 1 52 Over 14 12 to 16 12 6 1 83 Over 16 12 to 18 12 7 2 13 Over 18 12 to 20 12 7 5 2 29 Over 20 12 to 21 12 8 2 44 Figure 30 Height of Ve...

Страница 25: ...ng and drill a small hole through the ceiling and roof at this point From the roof locate the drill hole and mark the outline of the Cathedral Ceiling Support Box 3 Remove shingles or other roof cover...

Страница 26: ...35 and Initial Installation Vent Configurations and Restrictor Settings For other corner installations refer to Figure 36 and Initial Installation Vent Configurations and Restrictor Settings 5 Using t...

Страница 27: ...ee sections Initial Installation Installation of Rear Vented Appliance 1 Carefully remove the trivet and the stovetop Place on a soft surface as not to damage the porcelain finishes see Figure 37 2 Re...

Страница 28: ...position Attach a small section of pipe on the unit and mark exterior wall where vent would pass through the wall Cut a 10 25 4 cm minimum hole in the wall to maintain clearances to combustibles Fram...

Страница 29: ...stall the vent termination Seal around the termination using a non hardening mastic CORNER INSTALLATION This type of installation can be used in a corner installation If a 90 elbow is used in the hori...

Страница 30: ...or is not blocked or obstructed COOL HEAT PROGRAM DOWN UP 70 F TP TH TP TH O N O F F 70 F Optional remote control receiver ON OFF Remote thermostat switch Purple Grey Blue Grey Grey Optional Thermosta...

Страница 31: ...is utilized for the venting we recommend the vent connector be connected to an approved 4 10 cm diameter flue liner running the full height of the chimney In many jurisdictions this flue liner may be...

Страница 32: ...on off remote rocker switch wire see Figure 43 3 Remove the four mounting screws holding the spill switch bracket and remove the bracket see Figure 47 4 Remove and replace the spill switch with a 50 8...

Страница 33: ...pressure exceeds PSIG 3 45 KPa or damage will occur to the valve The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure tes...

Страница 34: ...servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing TP TH TP TH IN OUT N L O I H T O P L O I F OF C CO OO OL L H HE EA AT T P PR RO OG...

Страница 35: ...wall outlet and turn the unit on to ensure fan operation Installation of Log Set and Embers The placement of the logs is not arbitrary If they are positioned incorrectly the flames can be pinched and...

Страница 36: ...ins Follow Figure 52 to Figure 59 3 A bag of ceramic fiber embers and rock wool embers is provided gently remove the ember material from the plastic bag Spread a layer loosely in a random manner acros...

Страница 37: ...sable to open a window or door as the unit will start to smoke and can irritate some people After the unit has gone through the first burn turn the unit off including the pilot let the unit get cold t...

Страница 38: ...anel is centered before tightening the four 4 screws completely refer to Figure 61 3 Slide the bottom brick panel into place under behind the top panel bracket the notched side is to rest on the fireb...

Страница 39: ...on the side of the screen with the inside edge of the cast door see Figure 64 2 Push safety screen into place until spring clips latch onto the cast doors Safety Screen Removal 1 If the unit has been...

Страница 40: ...screw check pilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas l...

Страница 41: ...1 5 Side Panel Right Painted EGWP 505 5 Side Panel Right Antique Chestnut 50 872 6 Cast Leg Each Painted EGWP 508 6 Cast Leg Each Antique Chestnut 50 875 7 Ash Shelf Painted EGWP 507 7 Ash Shelf Antiq...

Страница 42: ...DV Vent Kit With Coupler EC 061 14 Relief Door Gasket Only 50 3369 14 Window Channel Tape 50 634 14 1 Piece Glass With Tape EGWP 090 14 Inner Door Only Painted EGWP 092 Burner Control Assembly LP EGW...

Страница 43: ...tion Blower 115 V No Mount 50 512 Firebox Baffle 50 533 Valve Extension Rod With Knob 1 per set 50 555 27 Electronic Ignition Module 50 589 28 Control Panel 50 690 Drafthood Adapter 50 841 Drafthood A...

Страница 44: ...44 Parts Diagram Components 13 17 16 10 27 15 26 24 9 22 11 21 25 29 20 14 19 23 12 28 18 WESTPORT Components January 2005...

Страница 45: ...ety screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused fro...

Страница 46: ...________________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yy...

Отзывы: