Operating Instructions
For Your Safety, Read Safety Precautions And
Lighting Instructions Before Operating
NOTE:
Check that all burner holes are lit.
TO TURN GAS FIREPLACE OFF:
Flip switch to OFF to turn off burners only
and turn the gas control knob to off to
extinguish the pilot flame. Keep the pilot
flame
OFF
when not in use. If the fireplace
is to be serviced, turn the gas shut off
valve to OFF (DO NOT FORCE IT) and
disconnect all electrical power sources.
See Figure 6 for control panel layout.
NOTE:
When the unit is turned on for the first time, it should be turned onto high, with the fan OFF
(if equipped), for the first two to four hours.
This will cure the paint, logs, gasket material, and other
products used in the manufacturing process. It is advised that a door or window be opened as the unit
will start to smoke, which can irritate some people. After the unit has gone through the first burn, turn
the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and clean
it with a good gas fireplace glass cleaner, available at your local Enviro dealer. See “
M
aIntenance
a
nD
s
erVIce
; G
lass
D
oor
r
eMoVal
”
and “
M
aIntenance
a
nD
s
erVIce
; c
leanInG
t
he
G
lass
.”
Figure 6. Control Panel
Figure 7. Fan Control
b
uRneR
L
ighting
:
A) Make sure the pilot is lit.
B) Turn gas control knob COUNTER CLOCKWISE to ON.
C) Flip the burner switch to ON.
D) Turn HI/LO knob to the desired flame height.
b
LoweR
sPeeD
(o
PtionaL
):
The blower will come on only when the fireplace is up to temperature
(approximately 15 minutes). The speed of the fan can be changed by turning
the fan control knob. The blower will continue to operate automatically after the
unit has been shut off (approximately 25 minutes).To turn the blower off, turn
the knob COUNTER CLOCKWISE until it “clicks” off (Figure 7).
It is advisable not to operate the blower below
1
/
3
speed as it puts a strain on
the windings of the blower and running the blower at lower speeds could also
cause premature fan failure.
n
oRmaL
s
ounDs
D
uRing
o
PeRation
:
Table 1: Normal Sounds
Component
Normal Sound Description
Q2 & Surround Panels
Creaking when heating up or cooling down caused by thermal expansion
Burner
Light pop or poof when turned off
Temperature Sensor
Clinking when it senses to turn the blower on or off
Pilot Flame
Quiet whisper while the pilot flame in on
Blower / Fan
Air movement that increase and decreases with the speed of the blower
Gas Control Valve
Dull click when turning on or off, this is the valve opening and closing
HI/LO
Control
Gas Control
Piezo Ignitor
Alternate Burner
Switch Location
DATE: 7/17/2014
BY
SHERWOOD INDUSTRIES LTD.
INTERNAL ASSEMBLY MANUAL
THIS DRAWING IS THE PROPERTY OF SHERWOOD INDUSTRIES LTD. AND MAY NOT BE COPIED, REPRODUCED, OR OTHERWISE DISCLOSED WITHOUT THE PRIOR APPROVAL OF SHERWOOD INDUSTRIES LTD.
1 of 2
SHEET:
Q2 (DV33) - R04
STOVE:
UPDATED: ----/--/--
BY --
REVISION:
0.0
Fan Control
(Optional)
Shut Off Valve
Page 9