Figure 20. Mantle Clearances
a
boVe
u
nit
:
A minimum 10” of non-combustible facing material, with a R-Value no less than 0.26, must
be used above the unit (in front of the included steel framing plate).
i
n
f
Ront
of
u
nit
:
The Q2G can be placed on the floor if desired although it is recommended that it be
raised aleast an inch or higher for more heat sensetive materials such as carpet or linoleum.
a
Djacent
/s
iDewaLL
:
There must be a minimum distance of
4 5/8” (417mm)
from the side of the Q2G
cabinet to an adjacent wall composed of combustible material (see Figure 19).
m
antLe
:
It is not necessary to install a mantle, but if one is desired the guidelines as shown in Figure 20.
Initial Installation
QUALIFIED INSTALLERS ONLY
49”
48”
47”
46”
45”
44”
43”
42”
1
2
3
4
5
6
7
8
9
10
11
12
M
A
N
T
L
E
H
E
IG
H
T
M A N T L E D E P T H
Minimum Mantle Clearances
12” MANTLE
2” MANTLE
Note: Mantle height dimensions are based from the bottom of the appliance.
Page 16