2. Start the pilot by pressing the gas control knob and turning it to PILOT.
While holding the gas control knob in, press the piezo ignitor several
times until the pilot light starts. Hold the gas control knob in for 30
seconds. Check that the pilot has fully engulfed the thermocouple
assembly (see Figure 4).
3. Start the main burner by turning the gas control knob to ON and then
turn the rocker switch to ON. Check that all burner ports have flame.
4. Leak test all gas joints again.
a
iR
s
hutteR
:
The air shutter adjustment lever is on the right hand side of the venturi box (see Figure 5).
The air shutter allows the amount of air coming into the fireplace to be adjusted in order to accommodate
different climates and venting arrangements. Start the pilot and then the burner. Make sure the pilot
flame is burning normally and none of the burner ports are plugged. Let the fireplace burn for roughly
fifteen minutes and then examine the flames, compare the flames to Figure 40.
The ideal flame will be blue at the base and light orange above. The flames should be of medium
height. If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and
mostly blue, the fireplace is getting too
much air. Therefore, the air shutter
should be closed (pulled out) slightly
until the correct flames are achieved.
Flames that are very orange, with tall,
dark, stringy tips, are not getting enough
air. Open (push in) the venturi until the
flames clean up. If the venturi is opened,
or closed all the way, and the correct
flames cannot be attained, turn off the
gas and contact the dealer.
Warning:
Incorrect venturi adjustment
may lead to improper combustion, which
is a safety hazard. Contact the dealer if
there is any concern about the venturi
adjustment.
Figure 5. Air shutter adjustment lever.
Thermopile
Thermocouple
Figure 4. Pilot Flame
8
Operating Instructions
P
iLot
L
ight
:
1. Turn off the gas to the fireplace.
If not recently done, remove the glass and let the unit air out
for at least five (5) minutes to clear out any gas.
Turn on gas to the heater. Leak test all joints
with soapy water.
NEVER USE OPEN FLAME FOR LEAK TESTING.
R
emote
contRoLs
:
This fireplace can use an optional remote control or an optional cordless wall thermostat. If either of
these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the
control panel) in the remote/thermostat position. Consult the instructions included with the remote/wall
thermostat for operation guidelines.
Less Air
More Air
Air Shutter Adjustment