HEAT LEVEL INDICATOR:
Shows the Heat Level output setting.
HEAT LEVEL ADJUSTMENT:
This button will change the Heat Level output setting of the stove from low to
high
ON/OFF BUTTON:
Is used to turn the unit ON and OFF
SYSTEM LIGHT:
The System Light is responsible for signaling the state of the control board.
When the light is flashing during start-up, the stove is in an automatic start
mode. When the light is solid, the Heat Level Setting can be altered.
MANUAL AUGER FEED:
If the unit runs out of fuel this button can be used to “prime the auger system”.
This button will turn off after 60 seconds and then must be released, then
pressed again
.
3 SECONDS “ON”
Standard Setting
2 SECONDS “ON”
4 SECONDS “ON”
AUGER LIGHT:
This light will flash when the auger motor is energized.
CONVECTION BLOWER CONTROL:
Used to turn the convection blower ON/OFF. If the Blower is left off, and the sensor located on the air jacket
reaches 160° F (71° C), the Convection blower will automatically come on HI speed to cool the unit. Leave the
convection blower ON for peak efficiency.
AUGER TRIM:
The Auger Trim Button is used to increase or decrease the feed rate on LOW, ONLY. Push the Auger Trim button until
the number 1 and 5 lights appear on the Heat Level Indicator. This will increase the feed rate to 4 seconds ON time
Auger pulse. This is done only on LOW to allow the burning of poor quality fuels. Push the button until the number
1 and 4 lights appear, this will reduce the Auger On time to 2 second. This setting is for high-grade fuel only. Push
the button until just the number 1 light is on, this is for a 3 second on time (standard setting).