background image

MANUFACTURED BY:

SHERWOOD INDUSTRIES LTD. 

6782 OLDFIELD RD.  SAANICHTON, BC, CANADA  V8M 2A3

www.enviro

fi

 re.biz

April 13, 2005

C-10857

Part Number

Option

50-1235

Horizontal Vent Kit  

Flue Pipe Adaptor

Wall Framing

Wall Thimble

Fire Stop

Exhaust 4" Flex Pipe

Combusion Air 6 5/8" Flex Pipe

Wire Spacers

Horizontal Vent Termination

9.   Install the 

fl

 ex pipe assembly through the wall thimble, ensure that this 

portion of pipe slides through the outside wall far enough to connect onto 

the vent termination cap.

10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) 

by 5” (12.5 cm) 

fl

 ue collar adaptor previously installed into the 

fi

 replace 

fl

 ue outlet.  Slide the Ø4” (10 cm) 

fl

 ex vent over the 

fl

 ue collar and secure 

with three (3) sheet metal screws evenly spaced.

11. Place a bead of high temperature silicone on the intake collar of the 

fi

 replace, slide the Ø6

” (16.25 cm) 

fl

 ex intake liner over the collar, 

secure the 

fl

 ex liner with three (3) sheet metal screws evenly spaced.

12. On the outside of the 

exterior wall, apply a 

bead of Mill-Pac Black 

sealant to the Ø 4” (10 

cm) pipe of the vent 

terminal.  Slide the 

fl

 ex liner onto the vent 

terminal and secure with 

three (3) sheet metal 

screws evenly spaced.

13. Place a bead of high 

temperature silicone on 

the intake collar of the 

vent terminal, slide the 

Ø6

” (16.25 cm) 

fl

 ex 

intake liner over the 

collar, secure the 

fl

 ex liner 

with three (3) sheet metal 

screws evenly spaced.

14. Attach the vent terminal 

to the outside of the 

house using four (4) 

wood screws provided. 

15. Light the appliance and 

ensure proper operation.