background image

2-3 Days / Weekly

Semi-annually or 2 Tons of Fuel

Burn Pot and Liner

Exhaust Vent

Ash Pan 

Fresh air Intake Tube

Inside Firebox

Blower Mechanisms

Door Glass

Heat exchanger tubes

Heat exchanger tubes

Behind firebox liners

Ash pan and Door gaskets

All Hinges

Door Latch

Post Season Clean-up

TOOLS REQUIRED TO CLEAN UNIT
• Torx T-20 Screwdriver   • Brush 

• Soft Cloth

• 

5

/

16

” Wrench or Socket  • Vacuum with fine filter bag

BURN POT AND LINER (2-3 days)

Routine Cleaning and Maintenance

The  following  list  of  components  should  be  inspected  and  maintained  routinely  to  ensure  that  the 

appliance is operating at its optimum and giving you excellent heat value:

Burn Pot Liner

Ignitor

Air Intake 

Tube

Burn Pot

Cleaning of the burn pot and liner must only be done when stove is cold. To remove the burn pot and 

burn pot liner, open the door using the door handle provided (located on the right-hand side of the stove). 

Swing the door open. Lift the liner from the burn pot. Lift the burn pot from the firebox by gently lifting up 

the front of the burn pot, then sliding the assembly from the air intake tube and the ignitor cartridge.
This is the ‘pot’ where the pellets are burned. Every two to three days (when the unit is cold), remove 

the burn-pot liner from the stove and inspected it to ensure proper air flow through the liner. Failure 

to keep the liner clean may cause a build up of fuel past the burn pot liner and up the drop 

tube.  This will cause the auger to jam and may result in pellets burning in the drop tube and 

hopper. Using a metal scrapper, remove material that has accumulated or is clogging the liner’s holes.  

Then dispose of the scrapped ashes from the liner and from inside the burn-pot. Place the burn-pot back 

into the stove, making sure that the pipes are properly inserted into the burn pot. Place the liner back 

into the burn-pot, making sure that the ignitor hole in the liner is aligned with the ignitor tube. Pushing 

the liner up against the ignitor tube.
If, after long periods of burning, the fire continually builds up and overflows the burn pot or there is a 

build up of clinkers, this is an indication that the pellet fuel quality is poor or the stove may need cleaning.  

Check the stove for ash build up (clean if required) and adjust the slider / damper to produce the proper 

clean combustion. 

DOOR LATCH (2-3 days)
Check the door latch every time the door is opened or closed to ensure proper movement.

DOOR GLASS CLEANING (When needed)
Cleaning of the glass must only be done when stove is cold. Open the door by lifting the handle. The glass 

can be  cleaned by wiping down the outside and inside of the glass with a dry soft cloth. 
If the glass has build up that can not be removed with only the cloth, clean the glass using paper towel 

and a gas appliance glass cleaner, this may be purchased through most dealers. If a gas appliance glass 

cleaner is not available, use a damp paper towel dipped in fly ash to clean the glass. After the glass has 

been cleaned use the dry soft cloth to wiping down the outside and inside of the glass.

Figure 7: Burn pot assembly.

10

Содержание Empress-A-FS

Страница 1: ...INSTRUCTIONS FOR FUTURE REFERENCE OWNER S MANUAL PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PRO...

Страница 2: ...Specifications 6 Dimensions 6 Operating Instructions 7 Control Board Functions 7 Automatic Safety Features of Your Pellet Stove 7 Operating Your Pellet Stove 7 Turning Your Pellet Stove Off 8 Slider...

Страница 3: ...Size to 5 16 diameter 1 long maximum Ash Content 1 maximum Premium grade 3 maximum Standard grade Moisture Content 8 maximum Heat Content approximately 8200 Btu per pound minimum ASH The ash content o...

Страница 4: ...ure that the structural integrity of the home is maintained and all construction meets local building codes Minor soot or creosote may accumulate when the stove is operated under incorrect conditions...

Страница 5: ...uids to start or freshen up a fire in the heater Keep all such liquids well away from the heater while it is in use SMOKE DETECTOR Smoke detectors should be installed and maintained in the structure w...

Страница 6: ...6 Specifications Dimensions Figure 1 Empress Dimensions 247 16 621mm 273 8 695mm 243 16 614mm 153 8 390mm 253 4 653mm 153 4 400mm...

Страница 7: ...the one that shows the current setting the default setting is the number 2 light To adjust the setting hold the Combustion Blower Trim button down and press the Heat Level up or down buttons to adjus...

Страница 8: ...hin the 30 minutes the HEAT LEVEL will return to the previous MANUAL setting If the thermostat contacts remain open the stove automatically begins its shutdown routine The ON OFF button can be presses...

Страница 9: ...aust blower is a variable speed blower controlled by the heat output button This blower will decrease the vacuum pressure inside the stove and as the heat output button is turned down SPECIAL NOTES Pe...

Страница 10: ...he auger to jam and may result in pellets burning in the drop tube and hopper Using a metal scrapper remove material that has accumulated or is clogging the liner s holes Then dispose of the scrapped...

Страница 11: ...f the stove just above the door This handle is to be pulled out a few times ONLY WHEN THE UNIT IS COLD in order to clean away any fly ash that may have collected on the heat exchanger tubes As differe...

Страница 12: ...per movement POST SEASON CLEAN UP Once you are finished using the pellet appliance for the season unplug the stove for added electrical protection It is very important that the stove be cleaned and se...

Страница 13: ...ain restrictions and exclusions apply to this warranty Limited Two 2 Year Warranty Under this warranty Sherwood Industries Ltd covers Ignitor Auger Motor Circuit Board Timers Temp Sensors Blowers Vacu...

Страница 14: ...ullify the Limited Warranty on this stove If unsure as to the extent of this Limited Warranty contact your authorized Enviro dealer before installation 10 Sherwood Industries Ltd will not be responsib...

Страница 15: ...r warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be covered 27 Sherwood Industries Ltd is not liable for freight or labour on any...

Страница 16: ...______________________________ PHONE ___________________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy D...

Отзывы: