1.   STOP! Read the safety information above on this label.
2.   Turn off all electrical power to this appliance.
3.   Turn off the gas control knob clockwise            to the off position.
4.   Open door. Wait fIve (5) minutes to clear out any gas. Close 

      door. If you smell gas STOP! Follow “B” in the  above safety  

      information. If you do not smell gas go to the next step.
5.   Find pilot-located to the right between the front and rear burner.
      Turn the gas control knob counter-clockwise             to  

      “PILOT”. Push the gas control in fully and hold, keep knob 

      depressed for about 30 seconds after the pilot is lit. 

      Release knob. If pilot goes out, repeat steps 4 

      through 5.

CAUTION:

Hot while operating. Do not touch, severe burns may result. Keep children, 

clothing, furniture, gasoline or other  flammable vapors away.

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

 PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. 

 A)  This appliance is equipped with a pilot, which must be lit by 
      hand by following these instructions exactly. 
 B) BEFORE LIGHTING smell all around the appliance area for
     gas and next to the floor because some gas is heavier than air

     and  will settle on the floor.    
   WHAT TO DO IF YOU SMELL GAS:

  Do not try to light any appliance. Do not touch any electrical  

  switch: do not use any phone in your building. Immediately call 

  your gas supplier from a neighbor's phone. Follow  the gas 

  suppliers instructions. If you cannot reach your gas supplier, call 

  the fire department.

C)   Use only your hand to push in or turn the gas control knob; 

       NEVERuse tools. If the knob will not push in or turn by hand, 

       do not try to repair it. Call a qualified service technician.  

       Force or attempted repair may result in a fire or explosion.
D)   Do not use this appliance if any part has been under water.
       Immediately call a qualified service technician to inspect the 

       appliance and to replace any part of the control system and  

       any gas controlwhich has been under water.     

LIGHTING INSTRUCTIONS

 WARNING: this gas valve has a lockout device, which will not 

   allow thepilot burner to be relit until the thermocouple has 

   cooled. If the knob doesdoes not pop up when released, stop 

   and immediately call your service technician or gas supplier. 

   If the pilot does not stay lit after several tries, turn the gas

   control knob  to “OFF” and call your service technician or 

   gas supplier.    
6.   Turn the gas control knob counter clockwise            to the 
      “ON” position. Flip the burner switch to “ON” THEN  TURN

      THE “HI/LOW” knob to the 

      desired setting.
7.   Turn on the electrical 
      power to the unit.

TO TURN OFF GAS TO APPLIANCE

1. Flip burner switch to “OFF”

2. Turn the gas control knob clockwise             to the “OFF” position.

3. Turn off all electrical power to the appliance if service is to 

     be performed.

CAUTION:

 Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a 

licensed or qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion 

and ventilation air. See installation and operating instructions manual. Keep burner and control compartment clean.

WARNING: 

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, or loss of life. 

Refer to owner's information manual provided with this appliance. For assistance or additional information consult a qualified installer, 

service agency or the gas supplier. See installation and operating instructions accompanying appliance. Installation and service must 

be performed by a qualified installer, service agency, or the gas supplier.

O

L I

T

P

TP

 T

H

    

  T

P

    

   T

H

IN

    

    

    

   O

UT

H

I

LO

N

OF

O

F

LI

P

T O

Figure 2: Lighting Instructions.

Содержание EG40 DV NG

Страница 1: ...life Installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other Flammable vapours and liquids in the v...

Страница 2: ...to the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury...

Страница 3: ...aration For Installation 12 Clearances to Combustibles 12 Planning Your Installation 13 Corner Installations 14 Mobile Home Installation 14 Vent Termination Restrictions 15 Freestanding Direct Vent Ki...

Страница 4: ...label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed with a listed wall thermostat IN USA see current ANSI Z223 1 for installation instruction...

Страница 5: ...mensions 25 635 mm 21 533 mm 12 1 2 318 mm 4 5 8 117 mm 29 1 8 740 mm Shipping Weight 256 lbs 116 kg Figure 1 EG40 Exterior Dimensions Rating Label Location The rating label is found inside the right...

Страница 6: ...attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace...

Страница 7: ...e of medium height If the flames look like this no venturi adjustment is needed If the flames are fairly short and mostly blue the fireplace is getting too much air Therefore the venturies should be c...

Страница 8: ...roblem Depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a soft cloth or a glass cleaner available...

Страница 9: ...bers and the door has been resealed re light the pilot following the instructions on the lighting label attached to the unit Cleaning Plated Surfaces It is important to note that fingerprints and othe...

Страница 10: ...arbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper or...

Страница 11: ...ure 12 O ring on valve screw is similar to what is shown in Figure 6 On some units you will need to pay special attention when installing the burner that the venturi adjustment rod is properly install...

Страница 12: ...ceiling joist Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room that is centrally located in...

Страница 13: ...from the appliance flue outlet to the ceiling the ceiling thickness the vertical rise through the attic or second story and allow for sufficient vent height above the roof line For two story applicati...

Страница 14: ...ation must be in accordance with the Manufactured Home Construction and Safety Standard UL 307B Title 24 CFR Part 3280 and or The Standard for Manufactured Home Installations ANSI A225 1 NFPA 501A Hol...

Страница 15: ...12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft 60 c...

Страница 16: ...aged INSTALLATION INSTRUCTIONS 1 Decide on a location for the unit that will meet any or all local code requirements Refer Planning Your Installation and Clearances to Combustibles 2 Set the appliance...

Страница 17: ...crews evenly spaced 12 Dress the flex liner through the wall thimble and attach the vent terminal to the outside of the house using four 4 wood screws provided The use of non hardening mastic should b...

Страница 18: ...w in the tab on the inside finished collar This will prevent the pipe from being disconnected at the vent terminal 23 Light the appliance and ensure proper operation Other Approved Vent Parts Table 3...

Страница 19: ...p 988 4DT WS B SV4BM 4DWS Wall strap support band 970 4DT HKA SV0SHK 4DHTK1 Horizontal termination kit SD Basic Kit SEL Kit A SC Standard Kit 911 11 to 14 pipe adjustable 4DT AJ 4D12A 4 to 10 pipe adj...

Страница 20: ...ination of rise and run can be used as long as it lays within the shaded area a total of three 3 90 elbows or six 6 45 elbows can be used In addition to what is shown if a 90 elbow is used in the hori...

Страница 21: ...Wall Thimble Strap Sheet metal screws Fold strap here 11 4 3 2cm Figure 26 Installing Decorative Wall Thimble 10 254mm 10 254mm Figure 25 Wall Framing Hole for Horizontal Installation Initial Install...

Страница 22: ...a chase the minimum clearance to combustibles is 2 5 cm Wood screws x4 Cut vinyl siding away to fit standoff Bolt x4 required Nut x4 required Wood screw x4 required Figure 27 Installing Vent Cap with...

Страница 23: ...le drilled in Step 2 Frame the hole as shown in Figure 29 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance Vertical Termination Storm Collar Flashing Roofi...

Страница 24: ...er the pipe and push it down to the top of the roof flashing as shown in Figure H Dimension H obtained from table below Table 5 Minimum H for Figure 31 Roof Pitch Minimum Height Ft Meters Flat to 7 12...

Страница 25: ...eiling and roof at this point From the roof locate the drill hole and mark the outline of the Cathedral Ceiling Support Box 3 Remove shingles or other roof coverings as necessary to cut the rectangula...

Страница 26: ...install the flex liner to the retro adapter Fully line the CLASS A chimney with a minimum 4 10 cm flex liner to the top of the CLASS A chimney Place a bead of high temperature silicone to the Simpson...

Страница 27: ...0 in the U S WARNING Electrical grounding instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and must be plugged directly into a properl...

Страница 28: ...ndividual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water soluti...

Страница 29: ...embly See Figure 31 or 34 for proper ember placement DO NOT pack this ember material as this could create an unsafe condition leave embers loose Carefully remove logs from box Check to ensure there is...

Страница 30: ...t up watch for ignition to ALL burner ports If a long delay is noted First wait for the appliance to cool down Open the front door of the appliance Check to carefully reposition the embers making sure...

Страница 31: ...screw check pilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas l...

Страница 32: ...ght Bulb Holder EC 032 Wiring Harness Complete 2 pieces EC 037 Body Wiring Harness EC 037A Burner Wiring Harness EC 037B Fan Control Knob EC 040 IEC Power Cord 115V EC 043 4 oz Bag Coal Embers Only EC...

Страница 33: ...or Hinge Set of 2 EG40 302 21 Fan Mount EG40 304 22 Pedestal Box Cover EG40 307 23 Burner Control Assembly NG 30 014 23 Burner Control Assembly LP 30 015 24 Front Pan Burner 30 016 25 Rear Burner with...

Страница 34: ...Parts Diagram Chassis 15 1 28 21 14 22 18 19 12 17 7 13 EG 40 Body Chassis July 2004 34...

Страница 35: ...35 Parts Diagram Gas Tray Door EG40 Gas Tray Door Assemblies July 2004 27 8 20 9 23 2 4 5 10 6 11 16 26 25 24 3...

Страница 36: ...ust be provided by you or the dealer including serial number Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result...

Страница 37: ...______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Отзывы: