background image

11

Maintenance And Service

b)  Insert  a 

5

/

32

”  or  4  mm  Allen  wrench  into  the 

hexagonal key-way of the screw (see Figure 10), 

rotate  it  counter-clockwise  until  it  is  free  and 

extract it.

c)  Check  that  the  screw  is  clean  and  if  necessary 

remove dirt.

d)  Flip the screw (refer to Figure 11).
e)  Using  the  Allen  wrench  as  shown  in  Figure  10, 

rotate the screw clockwise until a torque of 9 inch 

lbs. 

WARNING!

 Do not over tighten the screw. 

It is recommended that you grip the wrench by 

the short side.

f)  Verify that if the conversion is from NG to LPG, 

the screw must be re-assembled with the red o-

ring visible (refer to Figure 12). If the conversion 

is from LPG to NG, the red o-ring of the screw 

must be not visible.

Figure 11: Flip valve 

screw.

g)  Re-attach  the  black  protection 

cap  that  was  removed  in  step  a 

(Figure 9).

8.  Reinstall  the  burner,  brick  panels, 

log  set,  embers,  and  glass  door. 

Also  refer  to 

S

ECONDARY

  I

NSTALLATION

 

- I

NSTALLING

 L

OG

 S

ET

 

AND

 E

MBERS

. When 

re-installing the burner, ensure that 

the burner to pilot hood relationship 

Figure 12: O-ring on valve screw.

is similar to what is shown in Figure 6. On some units you will need to pay special attention when 

installing the burner that the venturi adjustment rod is properly installed into the venturi adjustment 

piece welded to the burner venturi tube

9.  Reconnect the main gas line if it was disconnected and open the shut-off valve at the gas line to the 

unit.

10.  Use a small brush to apply a warm soapy water solution to all gas connections (use a half dish soap 

and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by 

using an approved pipe thread sealant or approved Teflon tape. NEVER USE AN OPEN FLAME WHEN 

TESTING FOR LEAKS.

11.  Reconnect the electrical power to the unit.
12.  Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and 

operation  and  proper  flame  appearance.  Also  refer  to 

S

ECONDARY

  I

NSTALLATION

  -  L

OG

  S

ET

 

AND

  E

MBERS

 

I

NSTALLATION

 for a flame appearance picture. 

13.  MAKE SURE that the conversion label is installed on or close to the rating label to signify that the 

unit has been converted to a different fuel type. 

Figure 10: Removing valve 

screw.

7.  Convert the SIT gas valve:

a)  Remove the black protection cap from the HI/LO knob by hand shown in Figure 9.

Содержание EG40 DV LPG

Страница 1: ...ur s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion m...

Страница 2: ...to the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury...

Страница 3: ...eparation For Installation 12 Clearances to Combustibles 12 Planning Your Installation 13 Corner Installations 14 Mobile Home Installation 14 Vent Termination Restrictions 15 Fireplace Horizontal Vent...

Страница 4: ...label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed with a listed wall thermostat IN USA see current ANSI Z223 1 for installation instruction...

Страница 5: ...MENSIONS 25 635 mm 21 533 mm 12 1 2 318 mm 4 5 8 117 mm 29 1 8 740 mm Shipping Weight 256 lbs 116 kg Figure 1 EG40 Exterior Dimensions RATING LABEL LOCATION The rating label is found inside the right...

Страница 6: ...attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace...

Страница 7: ...e of medium height If the flames look like this no venturi adjustment is needed If the flames are fairly short and mostly blue the fireplace is getting too much air Therefore the venturies should be c...

Страница 8: ...a temporary problem Depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a soft cloth or a glass clea...

Страница 9: ...bers and the door has been resealed re light the pilot following the instructions on the lighting label attached to the unit CLEANING PLATED SURFACES It is important to note that fingerprints and othe...

Страница 10: ...carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper o...

Страница 11: ...ure 12 O ring on valve screw is similar to what is shown in Figure 6 On some units you will need to pay special attention when installing the burner that the venturi adjustment rod is properly install...

Страница 12: ...ting a wall or ceiling joist Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room that is central...

Страница 13: ...from the appliance flue outlet to the ceiling the ceiling thickness the vertical rise through the attic or second story and allow for sufficient vent height above the roof line For two story applicat...

Страница 14: ...ation must be in accordance with the Manufactured Home Construction and Safety Standard UL 307B Title 24 CFR Part 3280 and or The Standard for Manufactured Home Installations ANSI A225 1 NFPA 501A Hol...

Страница 15: ...12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft 60 c...

Страница 16: ...190 cm length of 4 10 cm double walled flex pipe 12 9 16 tech screws 1 5 190 cm length of 65 8 16 8 cm double walled flex pipe 8 11 2 wood screws Please ensure that all components are supplied with t...

Страница 17: ...nal slide the 65 8 16 25 cm flex intake liner over the collar secure the flex liner with three 3 sheet metal screws evenly spaced 14 Attach the vent terminal to the outside of the house using four 4 w...

Страница 18: ...90 elbow black 950 4DT VS SV4VS Vinyl siding standoff sheild 942 4DT WT SV4RSN 4DWT Wall thimble 953 4DT SC SV4FC 4DSC Storm collar 963 4DT FS SV4BF 4DFSP Fire stop 988 4DT WS B SV4BM 4DWS Wall strap...

Страница 19: ...nation of rise and run can be used as long as it lays within the shaded area a total of three 3 90 elbows or six 6 45 elbows can be used In addition to what is shown if a 90 elbow is used in the horiz...

Страница 20: ...odscrews Wall Thimble Strap Sheet metal screws Fold strap here 11 4 3 2cm Figure 26 Installing Decorative Wall Thimble Figure 25 Wall Framing Hole for Horizontal Installation Initial Installation QUAL...

Страница 21: ...a chase the minimum clearance to combustibles is 2 5 cm Wood screws x4 Cut vinyl siding away to fit standoff Bolt x4 required Nut x4 required Wood screw x4 required Figure 27 Installing Vent Cap with...

Страница 22: ...le drilled in Step 2 Frame the hole as shown in Figure 29 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance Vertical Termination Storm Collar Flashing Roofi...

Страница 23: ...er the pipe and push it down to the top of the roof flashing as shown in Figure H Dimension H obtained from table below Table 5 Minimum H for Figure 31 Roof Pitch Minimum Height Ft Meters Flat to 7 8...

Страница 24: ...ling and roof at this point From the roof locate the drill hole and mark the outline of the Cathedral Ceiling Support Box 3 Remove shingles or other roof coverings as necessary to cut the rectangular...

Страница 25: ...nd install the flex liner to the retro adapter Fully line the CLASS A chimney with a minimum 4 10 cm flex liner to the top of the CLASS A chimney Place a bead of high temperature silicone to the Simps...

Страница 26: ...ng outlet DO NOT cut or remove the grounding prong from this plug CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify...

Страница 27: ...om the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 KPa Alw...

Страница 28: ...ly See Figure 31 or 34 for proper ember placement DO NOT pack this ember material as this could create an unsafe condition leave embers loose Carefully remove logs from box Check to ensure there is no...

Страница 29: ...ight up watch for ignition to ALL burner ports If a long delay is noted First wait for the appliance to cool down Open the front door of the appliance Check to carefully reposition the embers making s...

Страница 30: ...ew check pilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line...

Страница 31: ...Light Bulb Holder EC 032 Wiring Harness Complete 2 pieces EC 037 Body Wiring Harness EC 037A Burner Wiring Harness EC 037B Fan Control Knob EC 040 IEC Power Cord 115V EC 043 4 oz Bag Coal Embers Only...

Страница 32: ...Hinge Set of 2 EG40 302 21 Fan Mount EG40 304 22 Pedestal Box Cover EG40 307 23 Burner Control Assembly NG 30 014 23 Burner Control Assembly LP 30 015 24 Front Pan Burner 30 016 25 Rear Burner with Ve...

Страница 33: ...33 Parts Diagram Chassis EG 40 Body Chassis July 2004...

Страница 34: ...Parts Diagram Gas Tray Door EG40 Gas Tray Door Assemblies July 2004 27 8 20 9 23 2 4 5 10 6 11 16 26 25 24 3 34...

Страница 35: ...nty on all the Electrical Components and Gas Components against manufacturing defects Paint is covered against flaking This offer includes parts and labor for 1 year and for parts only thereafter Your...

Страница 36: ..._____________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Отзывы: