Specifications

R

ating

 L

abeL

 L

ocation

:

The rating label is located on the left side of the unit and is attached to a rectangular metal sheet that is 

chained to the fireplace.

D

imensions

:

Figure 1: E20 Unit Dimensions.

6

i

nstaLL

 D

epth

:

The available depth of install is 14.00” when using the Extruded Surround Panel and the 

Contemporary Surround Panel. When using the Keystone Surround Panel your install dept will 

inscreased to 14.75”

*Shown with 

Contemporary 

surround 

panel and 

Extensions*

Содержание E20I

Страница 1: ... causing property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier 4001609 W A R R A N T Y R E G I S T R A T I O N e n v i r o c o m w a r r a n t y E20I G A S F I R E P L A C E I N S E R T Version Française www enviro com fr html ...

Страница 2: ...all your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Massachusetts installations Warning This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Mass...

Страница 3: ...e performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burners have...

Страница 4: ...6 Cleaning The Painted Surfaces 16 Removing Valve Cover 17 Fuel Conversion 17 Conversion Kit Instalation 18 Initial Installation 20 Clearances to Combustibles 20 Minimum Fireplace Size 20 Direct Vent Model 20 Preparing Your E20 For Installation 21 Venting Fireplace Inserts 22 Direct Vent Vertical Vent Termination 23 Solid Fuel Fireplace Installation 25 Electrical Requirements 26 Gas Line Connectio...

Страница 5: ...with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed with a permanent wall thermostat for bedroom installations is required Consult the authority having local jurisdiction in your area IN USA see current ANSI Z223 1 for installation instructions Must be installed in accordance with local codes ...

Страница 6: ...is located on the left side of the unit and is attached to a rectangular metal sheet that is chained to the fireplace Dimensions Figure 1 E20 Unit Dimensions 6 Install Depth The available depth of install is 14 00 when using the Extruded Surround Panel and the Contemporary Surround Panel When using the Keystone Surround Panel your install dept will inscreased to 14 75 Shown with Contemporary surro...

Страница 7: ...round Extruded Surround Height 237 8 594mm 237 8 594mm 237 8 594mm Width 353 8 898mm 353 8 898mm 353 8 898mm Trimmable Surround Height Width 28 705mm 4113 16 1062mm Base Shelf Base Shelf Riser Height 1 41mm 2 54mm Width 383 8 975mm 36 937mm Depth Bottom 4 112mm Top 313 16 97mm 311 16 94mm 35 3 8 898mm 26 660mm 25 1 2 648mm 23 7 8 594mm 38 3 8 975mm ...

Страница 8: ...iance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Read the owner s manual including the section on Remote Control operation 3 Set the thermostat to the lowest setting 4 Turn off all electric power to the appliance 5 Do not attempt to light the pilot by hand 6 Wait five 5...

Страница 9: ...uiet whisper while the pilot flame in on Blower Fan Air movement that increases and decreases with the speed of the blower Gas Control Valve Dull click when turning on or off this is the valve opening and closing Table 2 Normal Sounds Venturi Adjustment The venturi adjustment lever is located on the right side of the unit below the door see Figure 4 The venturi allows the amount of air coming into...

Страница 10: ...f or index through Thermostat functions Figure 5 6 Figure 5 Proflame 2 Transmitter System Description The Proflame 2 Remote Control System consists of two 2 elements 1 Proflame 2 Transmitter 2 Integrated Fireplace Controller IFC and a wiring harness to connect to the gas valve and stepper motor ATTENTION TURN OFF THE MAIN GAS SUPPLY OF THE APPLIANCE DURING INSTALLATION OR MAINTENANCE OF THE IFC TU...

Страница 11: ... accordance with the particular Proflame 2 system configuration The IFC has a red reset button at the front right corner that is used is to synchronize the Transmitter when using the for the first time or after the batteries have been replaced Figure 6 Proflame 2 Transmitter LCD Screen Figure 7 Integrated Fireplace Controller Low battery alarm Key Lock Room Temperature Dimmer ON Set Point Temperat...

Страница 12: ...splay see Figure 7 Turn on the Appliance Press the ON OFF Key on the Transmitter The Transmitter display will show all active Icons on the screen A single beep from the IFC will confirm reception of the command and will commence to first ignite the pilot light followed by the main burner This should take about 10 seconds to complete Figure 8 Remote Control Display in Farenheit and Celcius Operatin...

Страница 13: ...ermostat Key Figure 4 until the word SMART appears to the right of the temperature bulb graphic Figure 11 To adjust the set temperature press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of the Transmitter Room Temperature Set Temperature Thermostat ON Figure 10 Remote Control Displays Set Temperature Remote Flame Control The Proflame 2 remote control ...

Страница 14: ...s used the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the IFC batteries are low No beep will be emitted when it receives an On Off command from the Transmitter This is an alert for a low battery condition for the IFC When the batteries are replaced the beep will be emitted from the IFC when the ON OFF Key is pressed See Initializing the Sys...

Страница 15: ...o or three times a season Do not clean the glass when it is hot Cleaning The Firebox Remove the logs carefully as they are very fragile Gently remove all the embers and rock wool and place on a paper towel Vacuum the bottom of the firebox thoroughly Carefully clean any dust off the logs and remove any lint from the burner and pilot At this time inspect the burner pan for cracking or severe warping...

Страница 16: ...rate the fireplace with the glass removed CAUTION GLASS MAY SEPARATE FROM DOOR Figure 19 Door Release Figure 20 Door Removal Remove the glass door by placing the hooked end of the door release tool in the hole on the door latch mechanism see Figure 19 and pulling the latch out then up over the lip on the door When the two 2 latches have been released tilt the door forward and then lift up to unhoo...

Страница 17: ...f the firebox see Figure 24 Figure 21 Screws Holding Burner Tray in Place Figure 23 Screws Holding Valve Cover in Place Figure 22 Removing Burner Tray Figure 24 Removing Valve Cover Fuel Conversion TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing Warning This conversion kit shall be installed by a qualified service agency in accorda...

Страница 18: ...oval 3 Carefully remove the log set and ember material if they are installed 4 Using a T 20 screwdriver remove the four 4 screws that hold the burner in place pointed out in Figure 25 Slide the burner to the left see Figure 26 then up and out of the firebox 5 Convert the burner orifice a Remove the main burner orifice with a inch deep socket see Figure 27 Figure 27 Orifice Removal Figure 28 Orific...

Страница 19: ...n the USA The appliance may be installed at higher altitudes Please refer to your American Gas Association guidelines which state the sea level rated input of Gas Designed Appliances installed at elevations above 2000 610 m feet is to be reduced 4 for each 1000 feet 305 m above sea level Refer also to local authorities or codes which have jurisdiction in your area regarding the de rate guidelines ...

Страница 20: ...ommended to use 12 of floor protection especially when carpet or linoleom flooring are used infront of the insert Minimum Fireplace Size Table 3 Minimum dimensions of fireplace for E20 to be installed into Width At Front Width At Back Height Depth Fireplace Dimensions 24 616 mm 18 460 mm 18 3 16 462 mm 14 355 mm Direct Vent WARNING This appliance has been designed to draw room air for proper heat ...

Страница 21: ...ews located on the center top of the stove above the door opening see Figure 33 Slide the collar plate backwards Properly secure the vent collar plate to the flexible vent pipe liner s previously installed in the chimney Be careful not to over stretch the liner s 6 Place the unit part way into the fireplace Connect the household gas line into the NPT receptacle at the lower left rear of the unit u...

Страница 22: ...tial Installation Preparing Your E20 For Installation Please reference the information in Table 4 and Figures 35 and 38 An approved chimney liner and rain cap must be used A throat connector or flashing must be installed to ensure a tight seal top performance safety and efficiency Carefully follow the manufacturer s instructions that accompany the chimney liner kit Use Flexmaster double walled alu...

Страница 23: ...nstallation 2 Stretch both the Ø3 76mm flex vent and the Ø2 51mm flex intake liner to the length needed to ensure the flex can be easily connected to the vent terminal 3 Install the flex pipe assembly up through the chimney ensure that the pipe slides through far enough to connect onto the Vertical Vent Cap Note For any chimney over 15 4 6m install the E20 15 2 3 Flex Vent part 50 1512 and the E20...

Страница 24: ...air to the venturi may need to be adjusted using the rod under the firebox see Figure 4 Also refer to Figure 64 for a flame appearance picture 2 51mm Air Inlet 3 76mm Exhaust Figure 37 Vertical Vent Cap Underside 6 Place a bead of high temperature silicone on the intake collar of the fireplace slide the Ø2 51mm flex intake liner over the collar secure the flex liner with three 3 sheet metal screws...

Страница 25: ...elves shields and baffles may be removed if attached by mechanical fasteners The chimney must be clean in good working order and constructed of non combustible materials Make sure that all chimney cleanouts are tight fitting and will not permit air to leak into the chimney Refractory glass doors screen rails screen mesh and log grates can be removed from the fireplace before installing the E20 FRO...

Страница 26: ...nd should be plugged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug CAUTION When servicing controls label all wires prior to disconnection Wiring errors can cause improper and dangerous operation Verify proper operation after servicing If any of the original wire as supplied with the appliance must be replaced it must be replaced with 1...

Страница 27: ... system The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds PSIG 3 45 KPa or damage will occur to the valve The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal t...

Страница 28: ... system Check pressures using a manometer When finished release pressure remove hose tighten set screw Always check for gas leaks with a soap and water solution after completing the required pressure test NEVER USE AN OPEN FLAME FOR LEAK TESTING 28 Initial Installation QUALIFIED INSTALLERS ONLY Figure 41 Valve Details Pilot Adjustment Screw Manifold Pressure Tap Inlet Pressure Tap Servo Regulator ...

Страница 29: ... Service in order to gain access to the valve from above The pilot adjustment screw can be found in Figure 41 OR Figure 42 Proper Pilot Flame 3 8 1 2 10 13mm Thermocouple Proper Flame Adjustment Initial Installation QUALIFIED INSTALLERS ONLY 1b The adjustment screw can be reached through the front of the unit using an eight inch flat head screw driver see Figure 35 for location on valve 2 Turn the...

Страница 30: ...e Base Shelf and Riser are sold separately Installation 1 If unit is running turn it off and allow it to cool completely 2 When using more than one riser each level must be attached using nine 9 8 T 20 screws provided see Figure 43 3 If installing with riser s the Base Shelf is to be fastened to the riser s with one T 20 screw at each end of the back see Figure 44 Figure 43 Combining 2 Base Shelf ...

Страница 31: ...any sharp edges 5 The panel can be touched up with a high temperature metallic black paint available from your dealer INSTALLATION 1 Install the mounting bushings and screws for the trimable panel onto the E20 unit using a T 20 Torx screwdriver 2 In the case of the 3 Sided Panel hang the surround on the appropriate hooks depending on the optional surround that will be used with the trimable panel ...

Страница 32: ...ures 51 52 Ensure the hooks are secure before releasing the surround The surround should be wiped with a damp cloth periodically REMOVAL Lift the surround straight up in order to unhook the notch on the hooks from the bushing Pull the surround away from the fireplace Place the surround where it will not be damaged Figure 51 Bushing Locations Figure 52 Bushing and Hook Close Up Access Panel removed...

Страница 33: ...round panel if the cabinet extensions are still installed Safety Screen Assembly 1 Attach the left right top bottom brackets onto the safety screen using a T20 screwdriver and the supplied sixteen 16 8 T20 screws see Figure 51 Do not over tighten the screws doing so could cause them to strip out of the screen frame 2 Lift the face upright in front of the fireplace with the four 4 hooks pointing to...

Страница 34: ...stall the burner tray that comes with the kit into the E20 firebox by hanging the five holes on the back side over the 5 screws that come through the rear of the firebox 2 Install the pilot shield extension as shown in Figure 58 the burner has been removed for clarity The shield will fit around the outside of the pilot shield that is installed in the unit 3 Secure the burner tray to the firebox by...

Страница 35: ... 61 2 Add the first large rock in front of the pilot box as shown in Figure 62 It should rest on top of the burner and the pilot box 3 Add the rock accents as shown in Figure 62 and 63 DO NOT PLACE ROCKS IN THE AREA INDICATED Figure 61 Glass Beads in Place LEAVE THIS AREA CLEAR Figure 62 Rock Accent Placement Figure 63 Rock Accent Placement 35 DO NOT PLACE ROCKS HERE ...

Страница 36: ...t the back of the firebox see Figure 63 Place the back brick panel on the ledge and ensure the panel is flush at the bottom and top refer to Figure 65 Do not push at the center of the panel 5 Slide the front of the left brick panel into the left lip at the front of the firebox Ensure the panel is flush to the side of the firebox and the back brick panel while still being hooked behind the front li...

Страница 37: ... left brick panel Figure 69 The top left log rests on the back log and utilizes the locater pin pointed out in Figure 67 Ensure it is flush against the left brick panel and against the back wall The placement of the logs is not arbitrary If they are positioned incorrectly the flames can be pinched and will not burn correctly The burner and one of the logs come with locator pins and ledges which ma...

Страница 38: ... irregularly onto and around the front of the burner to create a realistic look The ember wool comes in chunks that can be ripped into smaller pieces The front log has been removed for clarity See Figure 73 for complete log and ember set up with the front log WARNINGS DO NOT pack this ember material as this could create an unsafe condition The pieces should be lightly placed so they don t block an...

Страница 39: ...eplace for the first time since the log set and embers have been installed replaced watch for ignition at ALL the burner ports If a long delay is noticed turn the appliance off and wait for it to cool down Remove the glass and rearrange the ember material making sure none of the burner ports air holes are blocked Never operate the fireplace with the glass door removed Figure 73 Log Set and Ember I...

Страница 40: ...crew check pilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on thermopile If low see Pilot will not remain lit Check ther...

Страница 41: ...mestic Power Cord 115V EC 042 12 Heyco Strain Relief EC 044 13 E20 Pilot Shield 50 3378 14 E20 Burner Only 50 2358 15 E20 Door Complete 50 2348 16 E20 Glass C W Gasket 21 75 X 13 575 50 2349 17 Dual Bulb Door Gasket 10ft 50 634 18 E20 Valve Cover with Gasket 50 1492 19 E20 Burner Tray Only 50 2357 20 E20 Fan Only 50 2260 21 E20 Fan Mounting Bracket Only 50 1516 22 E20 Fan Assembly Complete 50 2346...

Страница 42: ...d Panel E20 50 2252 30 Extruded Surround Panel E20 50 2253 31 Trim able Surround Panel E20 50 2255 Rustic Red Brick E20 50 2256 32 Base Shelf E20 50 2258 33 Base Shelf Riser E20 50 2344 Fluted Liner E20 50 2361 Porcelain Liner Set E20 50 2366 Glass Burner with Clear Glass 50 2367 Glass Burner with Black Glass 50 2369 Rock Set 8 Pcs E20 50 2381 34 Four Sided Surround E20 50 2382 Log Kit E20 50 2383...

Страница 43: ...43 43 43 Parts Diagram Components 43 E20I C omponents 1 24 23 21 20 22 19 2 3 4 5 6 7 8 9 10 11 12 25 26 27 13 18 16 17 15 14 ...

Страница 44: ...44 Parts Diagram Options E20 Options 44 28 29 30 31 32 33 34 35 ...

Страница 45: ...45 45 45 45 Notes ...

Страница 46: ...fety screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from over firing due to incorrect setup or tampering Damage caused by incorrect installation To the Dealer Provide name address and telephone number of purchaser and date of purchase Provide date of pur...

Страница 47: ...__________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy DIRECT VENT B VENT NATURAL GAS NAT PROPANE LPG INLET GAS PRESSURE _________in WC MAIN BURNER ORIFICE __________ DMS PILOT ORIFICE _________OR________in diam INSTALLER S SIGNATURE ________________________...