36
Initial Installation
QUALIFIED INSTALLERS ONLY
a
ppRoVeD
V
enting
p
aRts
:
Table 5:
Approved Vent Manufacturers
Table 6: Vent Part Numbers
(must state if galvanized or black wanted)
This fireplace has been tested and certified
for use with the venting brand names liste
above in table 5. Refer to table 6 below for
part numbers of commonly used parts for
both venting systems. For more venting parts
please visit the respective manufacturers’
website.
WARNING: Do not mix parts from
different vent manufacturers’ systems.
Manufacturer
Brand Name
Nominal Sizes
ICC
EXCELDirect
5” x 8”
M&G Dura-Vent
Direct Vent Pro
5” x 8”
Selkirk
DIRECT-TEMP
5” x 8”
Selkirk
AMP DV
5” x 8”
Metal-Fab Inc.
Sure-Seal
5” x 8”
EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a DirectVent Pro
starting collar in conjunction with venting brand names listed in table 6. Use of these systems with
the DirectVent Pro starting collar is deemed acceptable and does not affect the Intertek listing of the
appliance.
M&G Duravent
Direct Vent Pro
ICC
EXCELDirect
Selkirk
DIRECT-TEMP
Amerivent
AMV DV
Metal-Fab
Sure-Seal DV
Description
58DVA-06
5DL6
5DT-06
5D6
6” pipe length
5D7
7” pipe length
58DVA-09
5DL9
5DT-09
9” pipe length
58DVA-12
5DL1
5DT-12
5D12
5D12
12” pipe length
58DVA-18
5DT-18
5D18
18” pipe length
58DVA-24
5DL2
5DT-24
5D2
5D24
24” pipe length
58DVA-36
5DL3
5DT-36
5D3
5D36
36” pipe length
58DVA-48
5DL4
5DT-48
5D4
5D48
48” pipe length
58DVA-60
60” pipe length
58DVA-E30
30° elbow
58DVA-E45
5DE45
5DT-EL45
5D45L
5D45L
45° elbow
58DVA-E90
5DE90
5DT-EL90
5D90L
5D90A, 5D90L
90° elbow
58DVA-VSS, DVA-BVS
VSS
5DT-VS/VSK
5DHVS, DVSK
5DVS
Vinyl siding standoff/sheild
58DVA-WT3, 58DVA-WTU3
5WT
5DT-WT
5DWT
5DWT, 5DWT11 Wall thimble
58DVA-SC
SQSC, SC
5DT-SC
5DSC
5DSC
Storm collar
58DVA-WFS
5DT-FS
5DFSH
Wall Fire stop
58DVA-FS
5CS
5DT-FS
5DFSP
5DFS, 5DSPFS
Ceiling Fire stop
58DVA-IS
5AS
5DT-AIS
5DAIS12, AIS36
5DIS
Attic Insulation Shield
58DVA-WS
5WS
5DT-WS/B
5DWS
5DWS
Wall strap/support/band
58DVA-VCH
5SVT
5DVT
High wind vertical termination
58DVA-HC
5HT
5DT-HC
5DHCS
5DHT
High wind horizontal termination
46DVA-WG
HTS
4DHWS
8DVTS
Wind / Heat Shield
5DAL
3” to 10” pipe, adjustable
58DVA-17TA
11” to 17” pipe, adjustable
58DVA-24TA
17” to 24” pipe, adjustable
5DLA30
16.5” to 29” pipe , adjustable
5DLS1
1 7/8” to 9” slip length pipe
5DLS2
1 7/8” to 21” slip length pipe
58DVA-F6
6EFA
5DT-AF6
5DF
5DF
Flashing, 0/12 to 6/12 roof pitch
58DVA-F12
6EFB
5DT-AF12
5DF12
5DF-12
Flashing, 7/12 to 12/12 roof pitch
58DVA-FF
6EF
5DFT
Flat Roof Flashings
58DVA-CFK
4MF
Masonary Flashing
Содержание C44I