Enviro C-10914 Скачать руководство пользователя страница 14

1

2

3

4

5

���� ������� �����

���� ���������� �����

���� ������� �����

������ ���������� �����

1

2

3

4

5

Figure 11: Restrictor plate settings.

Figure 12 shows the vent restrictor position required, 

relative  to  the  length  of  vent  pipe.    Longer  vertical 

vent lengths necessitate greater restriction; position 

1 is open and position 5 is maximum restriction (refer 

to Figure 11). To avoid injury, it is best to make this 

adjustment when the fireplace is cool or use welder’s 

gloves or oven mitts.
To access vent restrictor remove the valve cover plate 

from the right rear corner of the unit by undoing the 

two fastening screws.
Loosen the 1⁄4” hex head bolt and adjust to the correct 

setting.

14

This fireplace have been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS 

STOVES.  SELKIRK DIRECT-TEMP SYSTEM SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” 

and SELKIRK “METALBESTOS MDV VENT SYSTEM” kits are available for horizontal venting.  When using 

Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone 

should be applied to each outer vent joint, and Mil-Pac to each inner joint.  When planning an installation, 

it will be necessary to select the proper length of vent pipe for the particular requirements.  

A MINIMUM VERTICAL LENGTH OF 24” (61 cm) TO THE FIRST 90° ELBOW IS REQUIRED.

  

WITH THIS MINIMUM VERTICAL RISE, HORIZONTAL RUNS OF FROM 1 FT (30.5 cm) to 3 FT (91.5 cm) 

ARE PERMITTED TO REACH THE OUTSIDE VENT TERMINATION.
BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION 

FOR THE VENT TERMINATION CAN BE ACCOMMODATED.  

FOLLOW THE VENT LENGTH DIAGRAM 

PRECISELY.
VENTING TERMINALS CANNOT BE RECESSED INTO A WALL OR SIDING. 
If extra elbows are being used, overall allowable length will be reduced by 3 ft (91.5 cm) per 

additional elbow.

WARNING: Do not mix parts from different vent manufacturers’s systems.
EXCEPTION  TO WARNING:    This product  has  been  evaluated by  Intertek  for  using a  Direct  Vent  GS 

starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems.  Use 

of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the 

Intertek WH listing of the appliance.

V

ENT

 C

ONFIGURATIONS

 

AND

 R

ESTRICTOR

 S

ETTINGS

:

Figures 12 shows the range of venting options, it shows possible vent configurations if the unit is top 

vented,  for  vertical  and  horizontal  terminations,  any  layout  that  remains  within  the  shaded  area  is 

acceptable. Having the fewest number of elbows is ideal, as they tend to disrupt air movement. Using 

45˚ elbows is preferable to using 90˚ elbows. Also, a shorter vent system will perform better than a 

longer one.
The 

ENVIRO

 WESTPORT has been designed with a built in restrictor plate. The restrictor is designed to 

enhance flame appearance when installing this unit with vertical chimneys as well as installations with 

longer horizontal vent applications. It does this by controlling the amount of air moving through the vent 

pipe.

Initial Installation

QUALIFIED INSTALLERS ONLY

Содержание C-10914

Страница 1: ... the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or ...

Страница 2: ...s to the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burners have gone out on their own open the glass door and wait 5 minutes to air out before attempting to re light the stove Always keep the area around these appliances cl...

Страница 3: ...nstallation 16 Corner Installations 18 Vertical Installation 19 Cathedral Ceiling Installation 21 Freestanding Direct Vent Kit With Coupler 22 Venting into a Class A Chimney 25 Converting Top Vented into Rear Vented 26 Installation of Rear Vented Appliance 26 Installation of Top Vented Horizontal Termination 27 Installation of Top Vented Vertical Termination 27 Freestanding Drafthood Adaptor 28 Ga...

Страница 4: ...O ANSI Z21 88a 2003 CSA 2 33a 2003 VENTED GAS FIREPLACE HEATERS CAN CGA 2 17 M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P 4 1 02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO WESTPORT Fireplace Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be ins...

Страница 5: ...cm CLEARANCES TO COMBUSTIBLES A Sidewall to unit 11 inches 27 9 cm B Backwall to unit 2 5 inches 6 35 cm C Corner to unit 2 5 inches 6 35 cm D Ceiling 60 inches above floor 152 4 cm E Floor hard wood and linoleum 0 inches Note When installing on a carpeted surfaces a non combustible hearth pad must be used Minimum Alcove Dimensions Width 48 inches 121 9 cm Height 60 inches 152 4 cm Depth max 24 in...

Страница 6: ... gas supplier HOT WHILE OPERATING DO NOT TOUCH KEEP CHILDREN CLOTHING FURNITURE GASOLINE OR OTHER FLAMMABLE VAPOURS AWAY A This appliance is equipped with a pilot which must be lit by hand by following these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas and next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SME...

Страница 7: ...ace to be adjusted in order to accommodate different climates and venting arrangements Start the pilot and then the burner Make sure the pilot flame is burning normally and none of the burner ports are plugged Let the fireplace burn for roughly fifteen minutes and then examine the flames compare the flames to Figure 55 Gas valve regulator Gas valve Primary air adjustment rod Figure 5 Gas Valve In ...

Страница 8: ... problem The glass will need cleaning about two weeks after installation Use a mild glass cleaner and a soft cloth abrasive cleaners will damage the glass and plated surfaces Depending on the amount of use the glass should require cleaning no more than two or three times a season Do not clean the glass when it is hot CLEANING THE FIREBOX Remove the logs carefully as they are very fragile Gently re...

Страница 9: ... door must be done by a licensed or qualified service person The glass must be purchased from an ENVIRO dealer No substitute materials are allowed To Replace Open door and remove the glass carefully Install the new piece of glass with the large bulb in the gasket tape against the unit Place the joint in the tape in a bottom corner Close door OPENING THE DOOR Turn unit off and wait until the applia...

Страница 10: ... Shut the gas supply off at the shut off valve CAUTION The gas supply shall be shut off prior to disconnecting the electrical power before proceeding with the conversion Step 3 Remove the glass as shown in the MAINTENANCE AND SERVICE OPENING THE DOOR Using a 1 2 deep socket remove reinstall the main burner orifice Undo the two 2 screws that hold burner in the firebox Rotate handles and remove the ...

Страница 11: ... half dish soap and half warm water If a gas leak is present bubbling will occur Gas leaks can be repaired by using an approved pipe thread sealant or approved Teflon tape NEVER USE A NAKED FLAME WHEN TESTING FOR LEAKS Step 14 Re light the fireplace to ensure proper operation and proper flame appearance refer to Figure 55 Step 15 MAKE SURE that the sticker provided by S I T is installed to signify...

Страница 12: ...ed C 12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft 60 cm from center line of terminal E 18 in 45 cm Clearance to unventilated soffit F 12 in 30 cm Clearance to outside corner G 12 in 30 cm Clearance to inside corner H 3 ft 91 cm within a height of 15 ...

Страница 13: ...T VS SV4VS Vinyl siding standoff sheild 942 4DT WT SV4RSN 4DWT Wall thimble 953 4DT SC SV4FC 4DSC Storm collar 963 4DT FS SV4BF 4DFSP Fire stop 988 4DT WS B SV4BM 4DWS Wall strap support band 970 4DT HKA SV0SHK 4DHTK1 Horizontal termination kit SD Basic Kit SEL Kit A SC Standard Kit 911 11 to 14 5 8 pipe adjustable 4DT AJ 4D12A 4 to 10 pipe adjustable SV4LA12 11 2 to 12 pipe adjustable 943 4DT AF6...

Страница 14: ...ERMINATION BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE VENT TERMINATION CAN BE ACCOMMODATED FOLLOW THE VENT LENGTH DIAGRAM PRECISELY VENTING TERMINALS CANNOT BE RECESSED INTO A WALL OR SIDING If extra elbows are being used overall allowable length will be reduced by 3 ft 91 5 cm per additional elbow WARNING Do not mix parts from different vent manu...

Страница 15: ...ing temperature to ensure proper and clean burning unit Note 0 0 in Figure 12 represents a 90 bend directly off the outlet of the unit in all horizontal instances except when using Selkirk and having less than a 4 ft 1 22 m rise and 8 ft 2 44 m horizontal offset In this case a 1 foot 30 5 cm rise must be added below the 90 bend 15 PLANNING YOUR INSTALLATION When planning your installation it will ...

Страница 16: ...length must be within the shaded area of Figure 12 If a 90 elbow is used in the horizontal plane 36 91 4 cm must be subtracted from the allowable horizontal run There are three 3 basic types of Direct Vent System installations The three 3 types of installations are shown in Figures 13 through 15 Figure 13 Common Horizontal Installation Figure 14 Common Vertical Installation Round Support Box Wall ...

Страница 17: ...sh the pipe sections completely together then twist lock one section clockwise approximately 1 4 turn until the two sections are fully locked The female locking lugs will not be visible from the outside on black Sealant Female Locking Lugs Male Locking Lugs Figure 16 Twist Lock Connection Woodscrews Wall Thimble Strap Sheet metal screws Fold strap here 11 4 3 2cm Figure 18 Installing Decorative Wa...

Страница 18: ...ive wall thimble will conceal it see left image in Figure 18 STEP 7 Slide the decorative wall thimble up to the wall surface and attach with the screws provided Apply decorative brass or chrome trim if desired see right image in Figure 18 Initial Installation QUALIFIED INSTALLERS ONLY Wood screws x4 Cut vinyl siding away to fit standoff Bolt x4 required Nut x4 required Wood screw x4 Figure 19 Inst...

Страница 19: ... of a fire 2 The location of the horizontal vent termination on the exterior wall must not be easily blocked or obstructed Refer to INITIAL INSTALLATION VENT CONFIGURATIONS AND RESTRICTOR SETTINGS 3 When installing a vent pipe in a chase the minimum clearance to combustibles is 2 51 mm 4 Maintain manufacturer s clearances to combustibles with venting CORNER INSTALLATIONS Do not interfere with the ...

Страница 20: ... roof line due to the higher corrosion resistance STEP 6 Once the pipe sections have been joined and run up through the hole in the roof slip an elbow strap over the exposed sections bend the support straps outwards and push the elbow strap Initial Installation QUALIFIED INSTALLERS ONLY VERTICAL INSTALLATION STEP 1 Check the instructions for required clearances air spaces to combustibles when pass...

Страница 21: ...torm collar over the pipe and push it down to the top of the roof flashing as shown in Figure 24 Use the non hardening sealant around the joint between the pipe and the storm collar STEP 10 Twist lock the vent cap H Dimension H obtained from table below Table 5 Minimum H for Figure 25 Roof Pitch Minimum Height Feet Meters Flat to 7 8 1 0 3 Over 7 12 to 8 12 1 5 0 46 Over 8 12 to 9 12 2 0 61 Over 9...

Страница 22: ...is point From the roof locate the drill hole and mark the outline of the Cathedral Ceiling Support Box STEP 3 Remove shingles or other roof coverings as necessary to cut the rectangular hole for the Support Box Cut the hole 1 8 larger than the Support Box outline STEP 4 Lower the Support Box through the hole in the roof until the bottom of the Support Box protrudes at least 2 inches 5 cm below the...

Страница 23: ...ing deflector 1 5 190 cm length of Ø4 10 cm double walled flex pipe 2 24 61 cm section of Ø65 8 17 cm straight pipe Please ensure that all components are supplied with this kit If components are missing or have been damaged contact your dealer distributor or courier company Do not attempt the installation if components are missing or damaged INSTALLATION INSTRUCTIONS 1 Decide on a location for the...

Страница 24: ...inal and secure with three 3 sheet metal screws evenly spaced 12 Dress the flex liner through the wall thimble and attach the vent terminal to the outside of the house using four 4 wood screws provided The use of non hardening mastic should be used around the vent to ensure a watertight seal 13 Install two 2 wire spacer around the flex pipe Slide the horizontal section of pipe over the flexible li...

Страница 25: ...tab on the backside of the pipe so that the fastener would not be seen 22 Secure the horizontal section of pipe to the inside finished collar by installing a screw in the tab on the inside finished collar This will prevent the pipe from being disconnected at the vent terminal 23 Light the appliance and ensure proper operation Initial Installation QUALIFIED INSTALLERS ONLY Wall framing Horizontal w...

Страница 26: ...r to the top section of GS direct vent pipe and install the flex liner to the retro adapter Fully line the CLASS A chimney with a minimum 4 10 cm flex liner to the top of the CLASS A chimney Place a bead of high temperature silicone to the Simpson Cap adapter and securely attach the flex liner to the adapter Secure the cap adapter to the CLASS A chimney ensuring an airtight seal Install the vertic...

Страница 27: ...L INSTALLATION INSTALLATION OF REAR VENTED APPLIANCE 1 Carefully remove the trivet and the stovetop Place on a soft surface as not to damage the porcelain finishes 2 Remove the four 4 1 4 screws that hold the flue collar elbow to the unit body see Figure 34 3 Carefully remove the elbow being sure not to damage the gasket that is glued to the flue collar elbow it seals the flue to the firebox 4 Tur...

Страница 28: ...the vent section through the wall and then install the vent termination Seal around the termination using a non hardening mastic CORNER INSTALLATION This type of installation can be used in a corner installation If a 90 elbow is used in the horizontal plane 36 91 4 cm must be subtracted from the allowable horizontal run shown in Figure 12 Place the unit in place Drop a plumb bob from the ceiling t...

Страница 29: ...ither self tapping screws and or high temperature sealant WARNING During the fitting of the Drafthood Adaptor ensure that the wires are not pinched between the adaptor and the collar and or flue outlet Ensure that the opening of the Drafthood Adaptor is not blocked or obstructed Step 3 Being careful not to run any wiring tight across metal edges connect them to the valve and ON OFF switch refer to...

Страница 30: ...r any other approved constructed chimney vent system see Figure 40 41 Figure 40 Unit top venting styles Figure 42 Draft test place Figure 41 Unit rear venting style In either case the fireplace may be connected to the chimney vent using a 4 10 cm single wall vent connector If 4 10 cm B vent is used a minimum of 1 25 mm must be maintained between the vent connector and any combustibles CAUTION A mi...

Страница 31: ... allow it to cool 2 Disconnect the spill switch wires from the valve and on off remote rocker switch wire see Figure 40 3 Remove the four mounting screws holding the spill switch bracket and remove the bracket see Figure 43 4 Remove and replace the spill switch with a 50 885 Spill Switch Assembly using a T 20 torx type driver 5 Follow the reverse of the previous steps OPTIONAL FINISHING In install...

Страница 32: ... supply piping system during any pressure testing where the pressure exceeds 1 2 PSIG 3 45 KPa or damage will occur to the valve The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 KPa Always check for gas leaks with a soap an...

Страница 33: ...ower Supply Figure 46 Wiring Diagram For Fan Control Table 7 Recommended Thermostat Wire Size Wire Size Max Length 14 gauge 100 ft 30 48 m 16 gauge 60 ft 18 29 m 18 gauge 40 ft 12 00 m 20 gauge 25 ft 7 62 m 22 gauge 18 ft 5 49 m COOL HEAT PROGRAM DOWN UP 70 F 70 F O N O F F Optional Remote Control ON OFF Remote Thermostat Switch Purple Thermocouple Blue Thermopile Grey Inlet Pressure Tap Gas Contr...

Страница 34: ...an assembly into the wall outlet and turn the unit on to ensure fan operation INSTALLATION OF LOG SET AND EMBERS The placement of the logs is not arbitrary If they are positioned incorrectly the flames can be pinched and will not burn correctly The burner come with four 4 locator pins and the right log has two 2 ledges which make alignment easier Using the pictures provided carefully set the logs ...

Страница 35: ... across the burner tray Do not allow any embers to rest against pilot assembly See diagram provided for proper ember placement DO NOT pack this ember material as this could create an unsafe condition leave embers loose 4 Upon the first light up watch for ignition to ALL burner ports If a long delay is noted First wait for the appliance to cool down Open the front door of the appliance Check to car...

Страница 36: ...ng process It is advisable to open a window or door as the unit will start to smoke and can irritate some people After the unit has gone through the first burn turn the unit off including the pilot let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner available at your local ENVIRO dealer See MAINTENANCE AND SERVICE on how to remove door to clean gla...

Страница 37: ... the panel and line up the slots on the bracket with the holes at the top of the baffle Use two 2 of the provided screws to hold the bracket in place Ensure the top panel is centered before tightening the four 4 screws completely refer to Figure 57 3 Slide the bottom brick panel into place under behind the top panel bracket the notched side is to rest on the firebox bottom The panel should rest fl...

Страница 38: ...replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on thermopile If low see Pilot will not remain lit Check thermopile for minimum of 200 mV when burner is switched on Check wiring to thermostat for breaks Flame lifti...

Страница 39: ... Top Only No Grate Or Vent Insert Antique White 50 370 3 Top Only No Grate Or Vent Insert Inferno Red 50 371 3 Top Only No Grate Or Vent Insert Pearl Grey 50 372 3 Top Only No Grate Or Vent Insert Wedgewood Blue 50 373 3 Top Only No Grate Or Vent Insert Westport Green 50 374 3 Top Only No Grate Or Vent Insert Antique Chestnut 50 906 4 Side Panel Left Painted EGWP 504 4 Side Panel Left Antique Whit...

Страница 40: ...P 506IR 8 Cast Front Complete Doors Ash Shelf Pearl Grey EGWP 506PG 8 Cast Front Complete Doors Ash Shelf Wedgewood Blue EGWP 506WB 8 Cast Front Complete Doors Ash Shelf Westport Green EGWP 506WG 8 Cast Front Complete Doors Ash Shelf Antique Chestnut 50 873 Top Complete Top Vent Insert Grate Painted EGWP 501 Top Complete Top Vent Insert Grate Antique White EGWP 501AW Top Complete Top Vent Insert G...

Страница 41: ...41 Parts Diagram Cast WESTPORT Castings January 2005 ...

Страница 42: ... 039A 13 Fan Controller Knob EC 040 Domestic Power Cord EC 042 HEYCO Strain Relief EC 044 DV Vent Kit With Coupler EC 061 14 Relief Door Gasket Only EGWP 087 14 Window Channel Tape EGWP 089 14 1 Piece Glass With Tape EGWP 090 14 Inner Door Only Painted EGWP 092 Burner Control Assembly LP EGWP 099 Burner Control Assembly NG EGWP 100 Door Hinge Pin Silver EGWP 510 Fireplace Screen EGWP 513 Shoulder ...

Страница 43: ...50 343 Wiring Harness 50 348 Pressure Relief Door With Gasket Rod Brackets 50 366 Control Panel Decal 50 461 Inner Door Complete With Glass Handles 50 463 Embers 50 491 4 Flex Coupler 50 497 26 Dual Convection Blower 115 V No Mount 50 512 Firebox Baffle 50 533 Valve Extension Rod With Knob 1 per set 50 555 27 Electronic Ignition Module 50 589 28 Control Panel 50 690 Drafthood Adapter 50 841 Drafth...

Страница 44: ...Parts Diagram Components WESTPORT Components January 2005 44 ...

Страница 45: ...d against flaking This offer includes parts and labor for 1 year and for parts only thereafter Your dealer shall make all claims under this warranty in writing When filing a warranty claim please complete the following information on an official warranty claim form TO THE DEALER Name address and telephone number of purchaser and date of purchase Date of installation Name of installer and dealer Se...

Страница 46: ..._______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy NATURAL GAS NAT PROPANE LPG INLET GAS PRESSURE _________in wc MAIN BURNER ORIFICE __________ DMS PILOT ORIFICE _________OR________in diam INSTALLER S SIGNATURE ______________________________________...

Отзывы: