Enviro 828 DV.FS. Скачать руководство пользователя страница 8

5. INSTALLING BURNER CONTROL ASSEMBLY

 

 
Remove the controls from box, check for shipping damage. Remove burner 
tray from controls (one screw on each side between burners). 
 
Open door.  Remove grate rod by pulling up at each end.  Remove the 2 
screws behind the grate and one screw on each side of control opening in 
firebox. 
 
Extend flex gas line and place through hole in center of pedestal (freestanding 
and inserts) or through hole in right or left firebox side (insert only).  Lower the 
controls into place at the back while pulling the flex line through on other side.  
Lower front into place, the control knob may need to be pushed in to allow 
burner controls to fit. 
 
Install the two side screws, then install the front screws through the grate into 
the firebox.  Replace burner tray. 
 
Install the grate rod and logset. 
 

6. INSTALLATION OF LOG SET and EMBERS

 

Upon the first light up, watch for ignition to 

all

 burner 

ports.  If a long delay is noted: 

 

a) First, wait for the appliance to cool down 
b) Open the front door of the appliance. 

 
c) Checks to Carefully reposition the embers making sure 

that burner ports are not plugged solid or blocked 

 

 
 

CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE 

DOOR REMOVED 

 

 

INSTALLING THE LOG 

a. INSTALLING THE GLOWING EMBERS 

 

 

Carefully remove log from unit.  Check to ensure there is 
no damage.  It is very important to install this log in its 

proper position to insure safe optimum operating 

conditions. 

A bag of ceramic fiber embers is provided for use on the 

front burner ember tray. 
 

CAUTION:  Use only the type of ember material supplied 
with this appliance.  Due to the irregular size of the ember 

material there may be more than required.  Use only a 

single layer.  Do not pile embers.  The use of other foreign 
materials on the burners may create dangerous 

conditions. 
 

If over time, through cleaning and servicing, these embers 
require replacement, contact your nearest ENVIROGAS 

dealer for replacement embers. 
 

Gently remove the ember material from the plastic bag.  

Spreading these pieces evenly across the front of the 
ember tray.  Place a single layer of embers on top of the 

front burner.  Carefully avoid any clumping or large build-
ups. 

 
 

 

 

 

Do not pack down, leave embers loose. 

1.  Open the front door. 

 

 

 

DO NOT PLACE EMBERS ON THE REAR BURNER. 

8

Содержание 828 DV.FS.

Страница 1: ...nal injury or loss of life A qualified installer service agency or the gas supplier must perform installation and service WHAT TO DO IF YOU SMELL GAS Open windows Extinguish any open flame Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you...

Страница 2: ...ly sized and is of adequate height to provide the proper draft Inspect the venting system annually for blockage and any signs of deterioration Due to high temperatures the appliance should be located out of high traffic areas and away from furniture and draperies Do not operate with cracked or broken glass Under no circumstances should this appliance be modified Parts that have to be removed for s...

Страница 3: ...81 GAS FIRED GRAVITY AND FAN TYPE DIRECT VENT WALL FURNACE CGA INTERIM REQUIREMENT NO 41 1991 DIRECT VENT GAS FIREPLACES CGA INTERIM REQUIREMENT NO 55 ADDITION REQUIREMENTS FOR DIRECT VENT FIREPLACES CGA 2 17 M91 GAS FIRED APPLIANCES FOR USE AT HIGH ALTITUDE 2 ENVIROGAS 828 DIRECT VENT UNITS Have all been certified for use with either natural or propane gases See control panel and rating label Are...

Страница 4: ... INSERT WITH ZERO CLEARANCE KIT Part 828 134 After deciding where to locate the fireplace insert you must frame an opening to except the Zero Clearance Box to reduce the clearance to combustibles The framing dimensions are as follows 32 1 4 wide 29 3 8 high and a depth of 14 3 4 The header at the top front of the opening must be a 2x4 on edge or a cut out in the 2x4 to maintain clearances to combu...

Страница 5: ...8 unit to be disconnected and removed if the unit needs to be repaired The next step is to attach the top extension to the Zero Clearance box This is screwed to the top front edge The top framing bracket is in turn screwed to the top extension This top framing bracket has the same adjustment settings as the side framing brackets Once the Zero Clearance box has been assembled it can be attached to ...

Страница 6: ...a Simpson Dura Vent sealed co linear vent system using the Envirogas kit 828 135 DV insert co linear adapter 4 ASSEMBLY INSTRUCTIONS INSTALLATION Remove the packaging from the appliance pedestal or surround panels and burner controls check to make sure there is no damage Carefully check the glass door Do not use the unit if it is damaged In the event damage is found please report it to both the co...

Страница 7: ...sert s flexible gas line to the household gas supply using locally approved methods For units with optional fan place the power cord so it can be connected to the power supply Push the unit into its final position in the fireplace Adjust the leveling legs and tighten the lock nuts insuring that the appliance is stable and level Push the insert adapter box under the rear rail then push down on the ...

Страница 8: ...hecks to Carefully reposition the embers making sure that burner ports are not plugged solid or blocked CAUTION NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED INSTALLING THE LOG a INSTALLING THE GLOWING EMBERS Carefully remove log from unit Check to ensure there is no damage It is very important to install this log in its proper position to insure safe optimum operating conditions A bag of cer...

Страница 9: ...us operation Verify proper operation after servicing FAN INSTALLATION OPTIONAL FAN Efficiency and heat output of the unit increases with the operation of the fan This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug The a...

Страница 10: ...e tests ORIFICE SIZES PRESSURES AND BTU S The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system All models are equipped with a variable output gas control NATURAL GAS PROPANE ORIFICES Front Rear 51 DMS 49 DMS 59 DMS 56 DMS Manifold Press 3 5 wc 0 87 kPa 10 0 wc 2 49 kP...

Страница 11: ...l to 4 500 ft To adjust for higher altitudes Remove the access cover plate loosen the air shutter locking screws with a long screwdriver Rotate the air shutters to the correct setting The flame should be bright yellow in color and have a lively appearance If sooting occurs on the glass then the venturi opening may need to be increased 11 ...

Страница 12: ...ly within 3 feet 90cm horizontally from the center line of the regulator I Clearance to service regulator vent outlet 6 feet 1 8m minimum J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 inches 30cm minimum K Clearance to a mechanical air supply inlet 6 feet 1 8m minimum L Clearance above paved side walk or paved driveway located on p...

Страница 13: ...OUTSIDE VENT TERMINATION BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE VENT TERMINATION CAN BE ACCOMMODATED FOLLOW THE VENT LENGTH DIAGRAM PRECISELY VENTING TERMINALS CANNOT BE RECESSED INTO A WALL OR SIDING If extra elbows are being used overall allowable length will be reduced by 3 ft per additional elbow PLANNING YOUR INSTALLATION There are two ba...

Страница 14: ...hown in FIG 10 NOTE 1 Twist lock procedure four indentations located on the female end of the pipes and fittings are designed to slide straight onto the male ends of adjacent pipes and fittings by orienting the four pipe indentations so they match and slide into the four entry slots on the male end 2 Horizontal runs of vent pipe must be supported every three feet Wall straps are available for this...

Страница 15: ... excessive heat from possibly melting the vinyl siding material Note that the horizontal vent termination bolts onto the flat portion of the vinyl siding standoff shaded area in FIG 12 so that an air space will exist between the wall and the vent termination NOTES 1 The horizontal run of vent pipe must be level and should have a inch rise for every one foot of run towards the termination Never all...

Страница 16: ...d pipe and elbows may be utilized in the attic as well as above the roofline The galvanized finish is desirable above the roofline due to the higher corrosion resistance STEP 6 Once the pipe sections have been joined and run up through the hole in he roof slip an elbow strap Part 989 over the exposed sections bend the support straps outwards and push the Elbow Strap down to the roof level as shown...

Страница 17: ...s required at the second floor and any subsequent floors FIG 19 The opening should be framed to 10 inch x 10 inch inside dimensions in the same manner as shown in FIG 16 2 Any occupied areas above the first floor including closets and storage spaces which the vertical vent passes through must be enclosed The enclosure may be framed and sheetrocked with standard building materials However consult t...

Страница 18: ... the Support Box Step 6 Complete the Cathedral Ceiling Installation by following the same procedures outlined in Steps 4 through 9 for Vertical Termination FIREPLACE INSERT INSTALLATION Parts 923GK Chimney Liner Termination Kit 923F Co Linear Flex Connectors The Envirogas 828 insert may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National Pr...

Страница 19: ...ke sure it is tight 9 Re install the pilot assembly and re attach the thermocouple to the valve 10 Remove the nut on the gas regulator and place the black pin in the correct position for the fuel type re install the nut 11 Change the burner orifices with the alternate set NG 51 front 49 rear LPG 59 front 56 rear 12 Re install the control panel to the burner control assembly 13 Re install the burne...

Страница 20: ...ntrol knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the floor STOP Follow B in the above safety information If you don t smell gas go to next step 5 Find the pilot located to the right between the front and rear burner 6 Turn gas control knob counter clockwise to PILOT 7 Push the gas control knob in fully and hold...

Страница 21: ...the door assembly If the glass is damaged or broken a replacement door assembly including glass must be fitted To Replace open door fully Lift door vertically so that hinge pins lift out of hinge receivers Return the door assembly to dealer Your ENVIROGAS Dealer must replace door and glass assembly as a complete unit No substitute materials are allowed FOR CLEANING THE INSIDE OF THE FIREBOX Remove...

Страница 22: ...leed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit NOVASIT valve Check gasline pressure Check for flame impingement on thermopile if low see Pilot will not stay lit check thermopile for a Minimum of 300 mV when burner switched on Check wiring to thermostat for breaks Flame lifting Leak in vent pipe Improper vent configuration Terminal may b...

Страница 23: ...Regulated Valve Liquid Propane 828 086 Pilot Gasket 828 096 S I T piezo Ignitor 828 098 Door Latch Bolt 828 099 Painted Door Assembly w Glass A B 828 100 Outer Painted Door A 828 101 Gold Door Assembly w Glass A B 828 102 Outer Gold Door A 828 103 Inner Door with Gasket Glass B 828 104 Burner Tray NG with Manually Regulated Valve BV 828 105 Burner Tray LP with Manually Regulated Valve BV 828 106 B...

Страница 24: ... flaking This offer includes parts and labor for 1 year and for parts only thereafter Your dealer shall make all claims under this warranty in writing A TO A MAXIMUM OF SEVEN YEARS WHEN FILING A WARRANTY CLAIM PLEASE COMPLETE THE FOLLOWING INFORMATION ON AN OFFICIAL WARRANTY CLAIM FORM To the Dealer Name address and telephone number of purchaser and date of purchase Date of installation Name of in...

Страница 25: ..._________ Phone ___________________________________ Name of Installer ___________________________________________ Address ___________________________________________ ___________________________________________ ___________________________________________ Phone _____________________________________ Model ___________________________________ Serial Number __________________ Date of Purchase __________...

Отзывы: