PRE-BURN CHECK

: The burn pot liner holes must be clear and the liner installed properly against the 

ignitor tube and locked in place.  Check the hopper for enough pellets to start the unit. 

 

Note: 

Fuel Type can only be changed when the unit is cold. The thermostat mode can be changed during 

normal operation.
The unit has an automatic cleaning cycle; every thirty (30) minutes the agitator will turn continuously for 

one (1) minute to help clean out the burn pot liner. 

Figure 3: Thermostat Switch in 

MANUAL position.

Figure 4: Thermostat Switch in 

HIGH/LOW position.

Figure 5: Thermostat Switch in 

AUTO/OFF position.

FEED TRIM

ON/OFF

FUEL TYPE

HEAT LEVEL

AUTO/OFF

HIGH/LOW

MANUAL

PELLET

C-11256

MULTIFUEL

FEED TRIM

ON/OFF

FUEL TYPE

HEAT LEVEL

AUTO/OFF

HIGH/LOW

MANUAL

PELLET

C-11256

MULTIFUEL

1

2

3

4

5

6

7

MANUAL MODE:

All control of circuit board function is adjusted at the circuit board.

INITIAL START-UP:

 

Press the ON / OFF button.

 The stove will 

turn on. The Fuel Type Light will flash (the Auger Feed Rate is pre-

programmed during start-up). The Heat Level Indicator will show the 

Heat Level that the stove will run at after start-up.
If this is the first time the unit has been started or the unit has run 

out of fuel, the auger may need to be primed. If there is no fuel in the burn pot after two (2) minutes 

press the Feed Trim button until fuel starts to drop into the Burn Pot Liner (see “

O

PERATING

 I

NSTRUCTIONS

C

ONTROL

 B

OARD

 F

UNCTIONS

”). 

The agitator will not operate for the first five (5) minute after the ON button has been pressed. After the 

five (5) minutes it will pulse at the same interval as the feed auger.
When the start-up sequence is complete the unit will ramp up to its heat level setting, this may take up 

to ten (10) minutes.
Once a fire has been established, the convection blower will turn on after ten (10) minutes and the Fuel 

Type Light will turn solid. 

To OPERATE:

 Press the Heat Level buttons to change the desired Heat Level Output setting. 

The speed of the convection blower is controlled by the setting of the heat level. 
The Feed Trim button used in conjunction with the Heat Level adjustment buttons to adjust the Feed 

Trim. It can be increased by two (2) feed settings or it can be decreased by two (2) feed settings. 

HIGH/LOW MODE:

 (Requires a Thermostat or Timer)  

INITIAL START-UP

: See MANUAL MODE above.

OPERATION

:  When  the  thermostat  calls  for  heat  (contacts  are 

closed) the stove settings are adjustable as per Manual Mode.  When 

the thermostat contacts open, the HEAT LEVEL and Fans will drop 

down to the LOW setting until the thermostat contacts close again.  

The stove will come back to the previous HEAT LEVEL setting when 

the thermostat contacts close again.       

AUTO/OFF MODE:

 (Requires a Thermostat or Timer)  

INITIAL START-UP

:  See MANUAL MODE above.

OPERATION

:  When  the  thermostat  contacts  close,  the  unit  will 

light  automatically.  Once  up  to  temperature,  the  stove  operates 

the same as in MANUAL. When the thermostat contacts open, the 

stove’s HEAT LEVEL and Fans will drop down to the LOW setting for 

30 minutes. If the thermostat contacts close within the 30 minutes, 

FEED TRIM

ON/OFF

FUEL TYPE

HEAT LEVEL

AUTO/OFF

HIGH/LOW

MANUAL

PELLET

C-11256

MULTIFUEL

FEED TRIM

ON/OFF

FUEL TYPE

HEAT LEVEL

AUTO/OFF

HIGH/LOW

MANUAL

PELLET

C-11256

MULTIFUEL

1

2

3

4

5

6

7

FEED TRIM

ON/OFF

FUEL TYPE

HEAT LEVEL

AUTO/OFF

HIGH/LOW

MANUAL

PELLET

C-11256

MULTIFUEL

FEED TRIM

ON/OFF

FUEL TYPE

HEAT LEVEL

AUTO/OFF

HIGH/LOW

MANUAL

PELLET

C-11256

MULTIFUEL

1

2

3

4

5

6

7

8

Operating Instructions

the HEAT LEVEL will return to the previous MANUAL setting. If the thermostat contacts remain open, the 

stove automatically begins its shutdown routine. The stove will re-light when the thermostat contacts 

close again.

Содержание 50-1675

Страница 1: ...PERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESP...

Страница 2: ...dations 4 Operating Instructions 6 Dimensions Specifications 6 Control Board Functions 7 Automatic Safety Features of Your Pellet Stove 7 Operating Your Pellet Stove 7 Turning Your Pellet Stove Off 9...

Страница 3: ...stove needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLINKERING clinkers are silica sand or other impurities in the fuel that will form a hard mass during the...

Страница 4: ...ertain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for proper and safe operation o...

Страница 5: ...bearing capacity if existing construction doesn t meet load capacity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYST...

Страница 6: ...ations Description Fuel type Residential Pellet Heater 6mm 1 4 dia Pellets wood corn wheat barley grass only Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumptio...

Страница 7: ...nd arrow down to decrease heat 7 FEED TRIM BUTTON Used in conjunction with the Heat Level adjustment buttons to adjust the Feed Trim It can be increased by two 2 feed settings or it can be decreased b...

Страница 8: ...lished the convection blower will turn on after ten 10 minutes and the Fuel Type Light will turn solid To OPERATE Press the Heat Level buttons to change the desired Heat Level Output setting The speed...

Страница 9: ...stove will turn off AUTO OFF mode To turn the unit OFF turn the Thermostat down or Timer off n shut down the burn pot agitator will run continualy for two 2 minutes when on Pellet Fuel Type and fifte...

Страница 10: ...the agitator towards the back of the firebox to unlock it slide it to the left and lift it out of the burn pot liner 4 Lift the burn pot liner out of the stove 5 Lift the burn pot from the firebox by...

Страница 11: ...fter extended use the gasketing may come loose To repair this glue the gasketing on using high temperature fiberglass gasket glue available from your local dealer This is important to maintain an airt...

Страница 12: ...The blower motors has sealed bearings DO NOT lubricate this motor Check gaskets and replace if needed POST SEASON CLEAN UP Once you are finished using the pellet appliance for the season unplug the s...

Страница 13: ...n restrictions and exclusions apply to this warranty Limited Two 2 Year Warranty Under this warranty Sherwood Industries Ltd covers Ignitor Auger Motor Circuit Board Timers Temp Sensors Blowers Vacuum...

Страница 14: ...ify the Limited Warranty on this stove If unsure as to the extent of this Limited Warranty contact your authorized Enviro dealer before installation 10 Sherwood Industries Ltd will not be responsible...

Страница 15: ...vered per our warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be covered 27 Sherwood Industries Ltd is not liable for freight or l...

Страница 16: ...AL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE ____________...

Отзывы: