s
peciFications
:
Table 1: 1200-C & 1700-C General Information.
Model
1200 Insert
1700 Insert
Width x Depth
27¾” x 22”
(705 mm x 559 mm)
27¾” x 26.5”
(705 mm x 673 mm)
Height of body
19
1
/
16
” (484 mm) or 19
9
/
16
” (497 mm)
Fire box size
(depth x width x height)
16.1” x 18.25” x 11.15”
(409 mm x 464 mm x 283 mm)
20.65” x 18.25” x 11.95”
(525 mm x 464 mm x 304 mm)
Capacity
1.85 feet3
(0.0526 meter3)
2.5 feet3 (0.0708 meter3)
* Approximate heating area
800 - 1,500 feet2
(74.3 - 139.4 meter2)
1,000 - 2,200 feet2
(92.9 - 205.4 meter2)
**E.P.A. output rating
11,479 to 34,196 BTU/hour
(3,361 to 10,013 watt)
9,425 to 31,780 BTU/hour
(2,760 to 9,306 watt)
*Duration on low burn
6 -10 hours
8 - 12 hours
Weight with packaging
335 lb (151.95 Kg)
390 lb (176.90 Kg)
E.P.A. Emissions
3.3 grams/hour
(0.116 oz/hour)
4.48 grams/hour
(0.158 oz/hour)
Surround Panel
Standard (width x height)
49.25” x 31.25” (1251 mm x 794 mm)
Rating Label Location
Side of Unit; Behind Right Shroud
10
Specifications
a
ir
c
ontrol
:
The primary air is controlled by the rod located on the right side of the unit. To increase your air, pull the
rod out and to decrease, push the rod in. All the units have a secondary air that flows through the tubes
at the top of the firebox, just below the baffles.
Pull this control all the way out when first starting the
stove. Once the fire has been established you may
adjust this control to set the burn rate of the fire. For
optimal efficiency, use a low to medium setting. If this
damper is closed at first start-up, the fire will burn very
slowly and could soot the appliance.
When shutting down the stove, fully open the air
control. This allows the chimney temperatures to
remain as high as possible for as long as possible. Cold
chimney temperatures create creosote.
Figure 3: Air Control Rod.