7.6. Set Scan Time: 

 

 
 

ENVIRO TECHNOLOGY 

 

>>Set Scan Time 

 

Scan time: 001 

 
 

 

Steps: 

 

Can set scanning time from 1 to 4.

 

If we set scan time to 4 it will scan 1 channel four times and will show average of it on display.

 

Go to this menu and press enters .set scan time then presses enter.

 
 

7.7 System Info: 

 

 

This menu is used to verify the system’s har

dware and firmware information ,

 

it is read only.

 

Go to this menu using incr/decre key.

 

Press enter.

 
 

7.8 Back to main: 

 

 

Use to come back to main screen.

 

We can also come to main screen by pressing SEL key two times from main menu and by 
pressing SEL key three times if you are in sub menu.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

8 of 10 

 

Содержание 0202SCAN01

Страница 1: ...Manual V1 2 Thermoscan...

Страница 2: ...ations and Features 5 7 Keypad Functions 6 7 1 Admin Login 6 7 2 Display Mode 6 7 3 Alarm Param Set 7 7 4 Calibration offset 7 7 5 Contrast Control 7 7 6 Set Scan Time 8 7 7 System Info 8 7 8 Back to...

Страница 3: ...Decrement 3 Faster scanning and averaging of sensor Readings 4 Fast display updating 5 3rd wire compensation 2 1 1 08 07 2013 Pramila 6 System info menu added 3 1 2 22 12 2018 Akshada 7 Model No Adde...

Страница 4: ...2 of 10...

Страница 5: ...with RS485 port It is an updated hardware plus firmware version of thermoscan with fast sensor scanning and three wire compensation facility Can be configured for 8 channel stability 8 channel temper...

Страница 6: ...her pressing of key for 8 10 sec will increment count by 10 DEC Scroll the menu parameter Decrements numerical data for parameter setting To fast decrement press key for 3 sec it will decrement automa...

Страница 7: ...186 107mm 9 Weight 270gm 10 Keypad functions Admin Login To Access the menu of unit Display Mode To set channel format for either 8 channel temperature or 8 channel stability Alarm Parameter Set To se...

Страница 8: ...Login Fail message To log out go to Admin Login then press enter to logout If any key is not pressed within 60 sec then you will exit from program mode 7 2 Display Mode ENVIRO TECHNOLOGY Display Mode...

Страница 9: ...er key Do same procedure for humidity settings Temperature max range 200 C to 850 C Humidity range 1 for EE_1V 0 to 1 V 2 For Humidity 0 to 3 3V 7 4 Calibration offset ENVIRO TECHNOLOGY Calibration Of...

Страница 10: ...this menu and press enters set scan time then presses enter 7 7 System Info This menu is used to verify the system s hardware and firmware information it is read only Go to this menu using incr decre...

Страница 11: ...8 ETS TSN V1 1Connection Details 8 1 System Connection Details TEMPERATURE INPUT SIGNAL THERMOLOG HUMIDITY INPUT SIGNAL 12VOLT SUPPLY THERMOSCAN RS485 Converter PC 9 of 10...

Страница 12: ...or RS 485 14 36 22AWG 2 core shielded twisted cable RTD PT100 sensor Cable length 100metre MAX 0 to 1V humidity sensor cable length 3 meter max keep as short as possible 0 to 3 3V humidity sensor cabl...