enviro-tech ET3-M Скачать руководство пользователя страница 3

 

 

 
Sensor Test 

 This will confirm that the sensor has been installed correctly. Make sure silicone 

is dry before performing flush test - Pour water slowly over the surface of the urinal (must 
run over sensor location). If the red light on the controller is flashing, when you stop pouring 
water the red light will stay on - there will be a delay, but the urinal should flush.  
 

Outcome of Sensor Testing: 

 

 

I

F NO LIGHTS ON CONTROLLER OR UNIT DOES NOT FLUSH

,

 CHECK THAT SENSOR HAS BEEN INSTALLED 

CORRECTLY I

.

E

.

 THAT THE 

CERAMIC SIDE

 IS AGAINST THE URINAL CERAMIC AND THAT THE SILICONE 

HAS NOT SPREAD TO SENSING SURFACE

.

 

(

SEE DRAWING BELOW

); 

 

I

F  SENSOR  INSTALLATION  IS  CORRECT 

-

  CHECK  SENSOR  CABLE  CONNECTION  IS  FULLY  TIGHTENED

.

 

REPEAT TEST

.

 IF UNIT STILL DOES NOT FLUSH

,

 YOU MAY NEED TO REPLACE THE SENSOR

 

 

 

 

^

ALTERNATIVE INSTALLATION METHOD - VALVE MOUNTED IN-CEILING  

 

The requirements of this method of installation should have been discussed prior to 
purchase. Enviro-Tech recommends that an air-break valve be installed and the use of a 
single straight copper pipe between the solenoid outlet and the urinal, no horizontal 
sections or flexi-pipe. (See installation manual for further details). If you are experiencing 
problems with activation, ensure that your installation is correct.  
 
This product is pre-set to deliver 0.8l per flush at 350kPA, any adjustments to flow should be 
made on the flow valve, next to the inlet on the solenoid. Do not attempt to make any 
adjustments to the controller. 
 
Function of individual components can tested by following the component testing 
instructions for the in-wall installation method, detailed on Page 2. 
 

Next Steps: 

 
If testing has confirmed that a component is not functioning, call us or e-mail us to discuss 
(see our contact info over page). If you have multiple flush valves on site 

 see the Advanced 

Troubleshooting Section on Page 4.  
 

Отзывы: