DECIDING WHERE TO LOCATE YOUR STOVE 

DIMENSIONS: 

 

Front Width: 

36 5/8”/ 93 cm 

Rear Width: 

36 5/8”/ 93 cm 

Height:   

32 1/4”/ 82 cm 

Depth      13 11/16”/ 34.77 cm 
 
 
 

Shipping Weight: 132 lbs/59.9 kg 

 
 
 

 

CLEARANCES: 
 

A.

 Side wall to stove 

 

2”/    5 cm 

B.

 Rear wall to stove     

1”/ 2.5 cm 

C.

 Floor to stove 

 

0”/    0 cm 

D.

 Corner clearance 

 

1”/ 2.5 cm 

 

 

Maintain sufficient clearances 
for service and maintenance  

 
 
 

• 

The stove should be located out of traffic and away from furniture and draperies. 

• 

The stove should have sufficient access for its safe operation and maintenance. 

• 

Locate a position where the flue system of the stove can be properly installed without damaging the integrity 
of the building. e.g. cutting a wall or ceiling joist. 

• 

The stove can be installed on any wood or concrete surface. 

• 

Check stove and flue system clearance requirements. 

• 

Locate the stove where it can be accessed by a gas supply line. 

• 

Locate the stove in a large and open room that is centrally located in the house.  This will optimize heat 
circulation and comfort. 

• 

As the stove could be equipped with a convection fan, ensure that an electrical source is supplied to the 
chase that the unit has been installed.  

• 

These stoves can be installed in bedrooms. 

(

IN CANADA

: must be installed with a listed wall thermostat) 

(

IN USA

: see current ANSI Z223.1 for installation instructions.) 

• 

The flow of combustion and ventilation air must not be obstructed. 

 
 
 

MOBILE HOME 

• 

When the unit is installed in a Mobile Home it must be grounded to the steel chassis or connected to a 
grounding rod. 

 

• 

In a Mobile Home installation the unit must be bolted securely to the floor using the holes provided. 
Manufactured (mobile) home installation must be in accordance with the Manufactured Home Construction 
and Safety Standard, UL 307B, Title 24 CFR, Part 3280 and/or The Standard for Manufactured Home 
Installations, ANSI A225.1/NFPA 501A 

Содержание EG 33

Страница 1: ...AT TO DO IF YOU SMELL GAS Open windows Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s p...

Страница 2: ...allation must conform to local codes or in the absence of local codes with the current CAN 1 B 149 installation code in Canada or the current National Fuel Gas Code ANSI Z223 1 in the USA To prevent i...

Страница 3: ...e all been certified for use with either natural or propane gases see control panel and rating label Are not for use with solid fuels Must not be connected to a chimney flue serving a separate solid f...

Страница 4: ...here it can be accessed by a gas supply line Locate the stove in a large and open room that is centrally located in the house This will optimize heat circulation and comfort As the stove could be equi...

Страница 5: ...re that the top header above the framing opening is installed on the edge or upright this will maintain proper clearances to the vent pipe NOTE MAKE SURE THAT THE UNIT HAS BEEN INSTALLED SO THAT THE B...

Страница 6: ...supplied The unit can now be enclosed with the rest of the house finishing Place a sheet of drywall around the unit covering the nailing flanges and stopping on the unit body Place the finished tile...

Страница 7: ...PLIANCE YOU MUST STAY WITHIN THE SHADED AREA see venting chart provided FOR ALL VENTING APPLICATIONS VENT RESTRICTOR RING A vent restrictor ring is supplied with each direct vent fireplace This restri...

Страница 8: ...inimum C Clearance to permanently closed window minimum 12 inches 30 cm recommended to prevent condensation on window D Vertical clearance to ventilated soffit located above the terminal within a hori...

Страница 9: ...ption 908B 6 Pipe Length Black 907B 9 Pipe Length Black 906 B 12 Pipe Length Black 904 B 24 Pipe Length Black 903 B 36 Pipe Length Black 902 B 48 Pipe Length Black 911 B 11 to 14 5 8 Pipe Adjustable B...

Страница 10: ...n the pipe They may be located by examining the inside of the female ends as shown in FIG 10 NOTE 1 Twist lock procedure four indentations located on the female end of the pipes and fittings are desig...

Страница 11: ...nation bolts onto the flat portion of the vinyl siding standoff shaded area in FIG 12 so that an air space will exist between the wall and the vent termination NOTES 1 The horizontal run of vent pipe...

Страница 12: ...pipe and elbows may be utilized in the attic as well as above the roofline The galvanized finish is desirable above the roofline due to the higher corrosion resistance STEP 6 Once the pipe sections h...

Страница 13: ...required at the second floor and any subsequent floors FIG 19 The opening should be framed to 10 inch x 10 inch inside dimensions in the same manner as shown in FIG 16 2 Any occupied areas above the...

Страница 14: ...mbly 4 Spread ember pieces in a single layer evenly across the front burner ember tray Place a single layer of embers on top of the front burner 5 Carefully avoid any clumping or large build ups Do no...

Страница 15: ...f all electrical power to the appliance 15 HI LO knob Control knob 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smel...

Страница 16: ...the joint in the tape in a bottom corner Close door Glass must be purchased from an Envirogas dealer No substitute materials are allowed CLEANING THE INSIDE OF THE FIREBOX Remove the log carefully fro...

Страница 17: ...thermocouple Air in gas line Pilot flame dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pres...

Страница 18: ...ted from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kP...

Страница 19: ...bracket in the center rear of the appliance Place blower over the two screws provided on the base of the appliance 4 Install the electrical box on either the left side of the appliance This electrical...

Страница 20: ...ot injector Install the new pilot injector BE CAREFUL WHEN TIGHTENING THE PILOT FITTING YOU COULD BREAK THE CERAMIC IGNITER ELECTRODE STEP 6 Re install the pilot assembly in the reverse order of STEP...

Страница 21: ...er The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under this warranty in...

Страница 22: ..._________ 22 Name of Installer ___________________________________________ Address _________________________________________ __ ___________________________________________ ____________________________...

Отзывы: