MAC 10  Original VE5 SERVICE MANUAL 

 

PAGE 1 

 

 

 READ AND SAVE THESE INSTRUCTIONS  

 

WARNING!

 

 

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING :

 

 
 
A.  Installation work and electrical wiring must be done by qualified person(s) in 

accordance with all applicable codes and standards, including fire-rated 
construction. 

 
B.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and 

other hidden utilities. 

 
C.  If this unit is to be installed over a tub or shower, it must be marked as appropriate 

for the application. 

 
D.  Use this unit only in the manner intended by the manufacturer. If you have any 

questions, contact the manufacturer: 

ENVIRCO CORPORATION 

 

FEDDERS INTERNATIONAL 

Envirco Office 

 

Headquarters 

5601 Balloon Fiesta Parkway N.E. 

 

No. 728 Fuzhou Road 

Albuquerque, New Mexico 87113 

 

Haungpu District 

U.S.A. 

 

Shanghai 200001 PRC 

Tel  : 

(505) 345-3561 

 

Tel  :  (86) 512 6258 7180 

Fax : 

(505) 345-8875 

 

Fax :  (86) 512 6258 0035 

Email:  info@

envirco.com

 

 

Email:  info@[email protected] 

 

 

 

TRION LTD. 

 

FEDDERS INTERNATIONAL, 

INC. 

The Cavendish Centre 

 

DP Computers Building 

Winnall Close 

 

128 Joo Seng Road #05-01 

Winchester, Hampshire, SO23 0LB,  UK 

 

Singapore 368356 

Tel  : 

44 1962 840465 

 

Tel  :  65 286 0995 

Fax :   44 1962 828619 

 

Fax :  65 286 0859 

Email:  info@tri

on.co.uk

  

 

Email:  info@[email protected] 

 
 
E.  Before servicing or cleaning unit, switch power off at service panel and lock service 

panel to prevent power from being switched on accidentally. 

Содержание MAC 10 VE5 RSR

Страница 1: ...E5 FAN FILTER MODULE INSTALLATION AND SERVICE MANUAL STANDARD RSR RSRE MODELS Mac 10 and VE5 are registered Trademarks of the Envirco Corporation Albuquerque New Mexico U S A US Patents 4 560 395 and...

Страница 2: ...rer If you have any questions contact the manufacturer ENVIRCO CORPORATION FEDDERS INTERNATIONAL Envirco Office Headquarters 5601 Balloon Fiesta Parkway N E No 728 Fuzhou Road Albuquerque New Mexico 8...

Страница 3: ...II SERVICE REMOVAL AND INSTALLATION OF THE ROOM SIDE REPLACEABLE FILTER RSR RSRE 5 IV SERVICE REMOVAL AND INSTALLATION OF THE MOTOR STANDARD AND RSR MODELS 7 V SERVICE REMOVAL AND INSTALLATION OF THE...

Страница 4: ...prefilter is recommended every three to six months Step 1 To gain access to the prefilter remove the ceiling panel next to the unit if applicable Step 2 Switch the ON OFF switch to the off position S...

Страница 5: ...lding the HEPA ULPA filter to the lid assembly Step 3 Lift the lid assembly off the HEPA ULPA filter see Figure 2 Discard the used filter as per requirements of the applicable regulations Note Before...

Страница 6: ...ve the six screws and clips remove filter blocks and lower the filter as shown in Figure 3 Step 4 Inspect filter for visible damage if damaged set aside for replacement or repair Step 5 Place the filt...

Страница 7: ...MAC 10 Original VE5 SERVICE MANUAL PAGE 6 Figure 4 4 1 2 3 5 6...

Страница 8: ...t off cover Step 5 Make note of all wire locations for reinstallation later Step 6 Disconnect the two brown wires from the capacitor using a pair of pliers Step 7 Disconnect the motor wiring from the...

Страница 9: ...MAC 10 Original VE5 SERVICE MANUAL PAGE 8 Figure 5 Disconnect motor leads from capacitor ON OFF switch and three speed switch or speed control Prefilter Motor Venturi Ring Blower Wheel...

Страница 10: ...hile supporting the baffle assembly from below remove the four corner screws on the baffle assembly and lower the assembly see Figure 6 Step 3 Prior to removing motor blower assembly remove electrical...

Страница 11: ...oval of the motor mount bracket measure the precise location of the bracket on the motor Remove the bracket Step 7 Replace with the new motor and reassemble by reversing the above steps Set the locati...

Страница 12: ...ould be conducted to determine the filter condition and appropriate fan speed setting Figure 8 Optional Speed Control Units furnished with the optional speed control the speed control is standard with...

Страница 13: ...oltage amperage and distribution frequency Step 5 Replace HEPA ULPA filter if the air velocity remains low High Air Velocity Step 1 Flip switch from HIGH to MEDUIM to LOW on units with 3 speed switch...

Страница 14: ...10 Original VE5 SERVICE MANUAL PAGE 13 VIII MAC 10 VE5 Wiring Diagrams Figure 10 Figure 11 Standard Wiring for MAC 10 ON OFF switch Speed Control 10 Capacitor Optional Wiring for MAC 10 With Speed Con...

Страница 15: ...Standard Filter HEPA ULPA Optional 2 x 2 1 69514 004 69514 018 2 x 3 1 69514 019 69514 012 2 x 3 5 1 69514 020 69514 021 2 x 4 1 69514 006 69514 007 HEPA Filter RSR 2 x 2 1 69391 005 69391 006 2 x 3 1...

Страница 16: ...ny other commercial loss This warranty excludes certain expendable items such as light tubes prefilters etc ENVIRCO expressly disclaims and excludes from this warranty any responsibility for equipment...

Страница 17: ...MANUAL PAGE 16 cleanroom start up may be time consuming and recommends using 3 Velgrid readings taken on a diagonal as shown below Recommended Testing 8 readings with a Velgrid Factory Approved Testin...

Отзывы: