Envirco Hospi-Gard IsoClean 400 Скачать руководство пользователя страница 18

Hospi-Gard

®

 IsoClean

®

 800 & 400

HEPA Filtration System

18

Innovators in Clean Air Technology   |   www.envirco.com 

I n s t a l l a t i o n ,   O p e r a t i o n ,   &   M a i n t e n a n c e   M a n u a l

  

Limited Warranty

a) Unless otherwise set forth in the Sales Confirmation, Seller warrants to Buyer, for a period of twelve (12) months following 

the date of shipment  to the Delivery Location (the “Warranty Period”), that the Goods will be free from defects in material 

and  workmanship.  Notwithstanding  the  foregoing,  the  Warranty  Period  for  consumable  Goods  shall  in  no  event  exceed 

recommended replacement intervals set forth in the Instructions (hereinafter defined). If, prior to the expiration of the Warranty 

Period, Buyer informs Seller in writing of any breach of this limited warranty, then Seller may repair or replace the Goods that 

gave rise to such breach or, in Seller’s sole and exclusive discretion, refund the amounts that Buyer paid for such Goods. 

The foregoing limited warranties do not apply to (i) any defect in Goods not manufactured by Seller; and (ii) any Goods 

manufactured according to Buyer’s specifications.

(b) Buyer shall bear the costs of access, de-installation, re-installation and transportation of the Goods to Seller and back 

to Buyer. Any repair or replacement pursuant to this limited warranty shall not extend the Warranty Period. Seller does not 

warrant the Goods, or any repaired or replacement parts, against normal wear and tear. This limited warranty and remedy 

are expressly conditioned upon: (i) Buyer’s payment of the purchase price in full, (ii) Buyer giving written notice of the defect, 

reasonably described, to Seller within ten (10) days of the time when Buyer discovers or ought to have discovered the defect, 

(iii) the storage, installation, operation, use, and maintenance of the Goods in compliance with the published specifications 

and instructions provided by Seller or its suppliers or subcontractors (the “Instructions”), (iv) the existence of proper records 

of Buyer’s operation and maintenance of the Goods during the Warranty Period, (v) Buyer providing Seller with a reasonable 

opportunity to examine the Goods and the aforementioned records, and (vi) the absence of any unauthorized modification or 

repair of the Goods.

(c) Before any test may be used to evaluate the Goods, Buyer shall: (i) provide Seller with reasonable written notification of 

such test, (ii) allow Seller to be present during such test, and (iii) receive Seller’s consent to the conditions of such test, which 

consent will not be unreasonably withheld. If a test is performed on the Goods, and Seller has not consented to the conditions 

of such test, then this limited warranty shall be void.

(d)  THE  REMEDIES  SET  FORTH  IN  THIS  SECTION  ARE  BUYER’S  SOLE  AND  EXCLUSIVE  REMEDIES  FOR  ANY 

FAILURE OF SELLER TO COMPLY WITH ITS OBLIGATIONS UNDER THIS AGREEMENT, INCLUDING ANY BREACH 

OF THE LIMITED WARRANTY SET FORTH IN THIS SECTION. 

Correcting any defect in the manner set forth in this Section 

8 shall constitute complete fulfillment of Seller’s obligations and liabilities under the Agreement following the delivery of the 

Goods, regardless of whether a claim is based in contract law, tort law (including negligence, strict liability or otherwise), or 

other legal theory.

THE LIMITED WARRANTY SET FORTH IN THIS SECTION IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, 

WHETHER STATUTORY, EXPRESS, OR IMPLIED. EXCEPT AS SET FORTH IN THIS SECTION, SELLER MAKES NO 

EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY, 

NON-INFRINGEMENT, OR FITNESS FOR A PARTICULAR PURPOSE, OR ANY WARRANTIES ARISING FROM COURSE 

OF DEALING OR USAGE OF TRADE.

 Any other oral or written statements, whether contained in general advertising or other 

printed material, do not constitute warranties, and Buyer agrees that it is not entering into the Agreement in reliance upon any 

such statements.

  

Contact Envirco

For warranties, replacement parts, technical support, or any other questions please contact Envirco at 1-800-884-0002.  For 

tech support related issues including troubleshooting and warranty, please email [email protected].  For customer 

service related issues inlcuding parts ordering, please email [email protected].

Содержание Hospi-Gard IsoClean 400

Страница 1: ...Hospi Gard IsoClean 800 IsoClean 400 HEPA Filtration Systems INSTALLATION OPERATION AND MAINTENANCE MANUAL ENVIRCO Technical Support 800 884 0002...

Страница 2: ...l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l Table of Contents Introduction 3 Installation 4 Operation 5 Maintenance Service 7 Troubleshooting 11 Wiring Diagram 12 Specifications...

Страница 3: ...a negative pressure isolation room Simply roll the IsoClean into a standard room connect flexible ducting to the 6 in 152 mm collar on the top of the unit for partial exhaust or to the optional 8 in 2...

Страница 4: ...ery unit is tested prior to shipment to verify airflow and that the unit is leak free 2 Place the unit in its final operating position 3 Lock the wheel locks on the casters to keep the unit from accid...

Страница 5: ...EPA filter The airflow indicator should not be used as the only guide for when a filter change is necessary The unit should be checked at each use to ensure recommended room air changes per hour are b...

Страница 6: ...ed to the top of the lsoClean for the unit to run in the 100 exhaust mode An optional 8 inch 203mm Exhaust Collar with Flange is available to convert the lsoClean unit to the 100 exhaust mode 1 Remove...

Страница 7: ...FOR A NEGATIVE PRESSURE ISOLATION ROOM AND MONITORED TO ENSURE ITS CONTINUING PERFORMANCE Difficulty Achieving Negative Pressure The equipment may not be able to achieve or maintain negative pressure...

Страница 8: ...AUTION DISCONNECTTHEUNITFROMTHEELECTRICALPOWERSOURCEBEFOREATTEMPTINGSERVICE DONOT WORKINSIDETHEISOCLEANUVWITHTHEUVLIGHTON PROPERREPLACEMENTOFUVCONTAINMENTBAFFLES AFTERMAINTENANCEISMANDATORYTOMAINTAINS...

Страница 9: ...leakage and for filter loading The expected HEPA filter life should range from eighteen 18 months to two 2 years depending on the environment and prefilter maintenance schedule The filter indicator l...

Страница 10: ...the switch and squeeze the snap in legs to remove switch from side of the unit 2 Install new switch by snapping it into the cutout and then connecting it to the white connector Speed Control Switch 1...

Страница 11: ...een completed remove the HEPA filter The filter can now be disposed of as general waste Phenolic Decontamination ln facilities where the above decontamination procedures are prohibited or not feasible...

Страница 12: ...igher airflow setting 4 Check power supply for proper voltage amperage and distribution frequency 5 Check for down stream obstructions or erratic isolation room ventilation balance 6 Replace HEPA filt...

Страница 13: ...ard IsoClean 800 400 HEPA Filtration System 13 Innovators in Clean Air Technology I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l Wiring Diagrams Cont IsoClean 400 Wiring D...

Страница 14: ...Filter Media 99 99 at 0 3 micron minimum efficiency Prefilter MERV8 multi pleat anti microbial pleated prefilter with frame Motor 1 3 HP 0 25 kW direct drive three speed continuous duty Exhaust Port 6...

Страница 15: ...IsoClean 1 11055 8 inch A C Collar with Flange for 100 1 267745 001 Intake Grille Painted 1 37453 Exhaust Grille 1 61528 Minihelic Gauge 1 63360 Keylock 1 IsoClean 800 UV Part No Description Quantity...

Страница 16: ...ge for 100 1 267745 001 Intake Grille Painted 1 37453 Exhaust Grille 1 61528 Minihelic Gauge 1 63360 Keylock 1 IsoClean 400 UV Part No Description Quantity 10950 005 IsoClean 400 120V UV 1 10960 005 I...

Страница 17: ...d 10 x 10 x 8 800 ft3 12 x 12 x 8 1152 ft3 12 x 15 x 8 1440 ft3 12 x 15 x 9 1620 ft3 15 x 15 x 8 1800 ft3 15 x 20 x 8 2400 ft3 20 x 20 x 8 3200 ft3 800 Low 560 CFM 42 ACH 29 ACH 23 ACH 20 ACH 18 ACH 1...

Страница 18: ...the Goods during the Warranty Period v Buyer providing Seller with a reasonable opportunity to examine the Goods and the aforementioned records and vi the absence of any unauthorized modification or r...

Страница 19: ...Hospi Gard IsoClean 800 400 HEPA Filtration System 19 Innovators in Clean Air Technology I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l This page intentionally left blank...

Страница 20: ...O M Industrial Cleanroom Products MAC 10 Original MAC 10 IQ MAC 10 LEAC2 MAC 10 LEDC MAC 10 RFAC Ducted Ceiling Module DCM RSR AC or DC Control Systems Hospital Healthcare Hospital Healthcare IsoClean...

Отзывы: