background image

440

cleaning & mainTenance

KeeptheTherapure

®

440functioningproperlybycleaningthepermanentHEPAtypeFilterevery

fourweeks.Morefrequentcleaningwillbenecessaryiftheunitislocatedinanareawithahighlevel

ofairbornecontaminants(excessiveamountsofsmoke,petdander,etc.).

NOTE: Always make sure the Therapure

®

 440 is turned off and unplugged before cleaning.   

»

  Vacuuming will restore performance of the permanent HEPA type Filter. However, 

  the filter may appear stained. This is normal and does not affect performance in any way.

»

  Do not use water or any household cleaners or detergents to clean the permanent 

  HEPA type Filter.

»

  The inlet grill may be cleaned (after unit is turned off and unplugged) with a vacuum 

  or a slightly damp cloth. 
Cleaning the permanent HEPA type Filter

1. Releasetheinletgrillbypressingonthelockinglatch(seediagramofMainParts).

2. Removetheinletgrillfromtheunitasshownbelow.

3. GrasptheleftandrightframesofthepermanentHEPAtypeFilterthroughtheindentationson

thesidesofthefilterenclosureandremovethefilter.

4. TocleanthepermanentHEPAtypeFilter,usethebrushorcreviceattachmentwithavacuum

cleaner.Runtheattachmentalongtheinletandoutletsideofthefilter,cleaningbetweenthe

crevicesasmuchaspossible.

Do not use water or any household cleaners or detergents to  

 

clean the permanent HEPA type Filter.

5. OncethepermanentHEPAtypeFilterhasbeencleanedandcheckedforanypossibledamage,

replacethefilterbackinthereversedirectiondescribedhere.Plugintheunitand

hold down 

Timer + Power On button for 3 seconds

.Thecleanfilterlightwillgooffandyourcleaning

maintenanceisdone.ExposingtheTherapure

®

440tocandle/oil/fireplacesootandsmokeis

notrecommendedandwillrequiremorefrequentcleaning.

1.

2.

4.

3.

oPeraTing The TheraPure

®

 440

CONTROLS/SETTINGS:

Power Control 

–TooperatetheTherapure

®

440airpurifier,presstheON/OFFbuttontoturnon

theairpurifier.Pressthebuttonagaintoturntheunitoff.

Timer Control

–TheTherapure

®

440airpurifiercanbeprogrammedtoturnoffafterapreset

amountoftime.Pressthe“TIMER”buttontoprogramthetimer.Eachpresswilladdonehourupto

atotalof24hours.Keepingthebuttonpressedwillautomaticallyincreaseto24hours,1hourata

time,afterthatitwillturnbacktooff.

Fan Speed  Control

–TheTherapure

®

440hasthreedifferentspeedsofcleaning,LOW,MEDand

HI.Press“SPEED”buttontocyclethesettingsandselectthefanspeedyoudesire.Thespeedstate

willbeshownontheLEDdisplay.

Clean Filter Indicator Light – 

TheTherapure

®

440CleanFilterIndicatorLightwillturnoneach

timethefilterneedstobecleaned.Toresetthefilterindicator,presstheTIMERandtheON/

OFFbuttonstogetherfor3seconds.TheCLEANFILTERlightwillflash3timesandthenturnoff

completely,indicatingtheunithasbeenreset.

Night Mode 

–IftheUVlightbaristoobright,pressthe“NightMode”buttontoturnofftheUV

lightbarfeature,andthelighteddisplay.TheON/OFFindicator,however,willremainlit.Thenight

modeonlyturnsoffUVlightbarnottheactualUVfeature.

Reset Filter Control

–Pressdownthe“TIMER”and“ON/OFF”buttonfor3seconds,theclean

filterlightwillflash3timesandthenthecleanfilterlightwillturnoff,indicatingtheunithasbeen

reset.

UV Control 

–PresstheUV/VOCcontrolbutton“UV/VOC”toturnontheUVlamptokillharmful

airbornegermsandreduceharmfulVOC(volatileorganiccompounds).Pressitagaintoturnoffthe

UVandVOC.

UV/VOC

TIMER

TIMER

NIGHT

MODE

ON/OFF

SPEED

SPEED

FILTER CLEAN ON/OFF

UV / VOC

8

9

Содержание thera pure TPP440

Страница 1: ...by TP440 052511 air purifier with uv light by owner s guide TPP440 TPP440 air purifier with uv light...

Страница 2: ...idal protection to reduce germs and permanent HEPA type filtration to purify the air the Therapure 440 air purifier will greatly improve the quality of the air in your home office or other environment...

Страница 3: ...result in considerable damage to the unit Do not place the cord near a heated surface Do not operate this product with a damaged cord or plug Discard the product or return to an authorized service fac...

Страница 4: ...s mold and bacteria 3 speed fan setting lets you select the desired cleaning level main parts 1 Locking Latch 2 Air Inlet Grill 3 Permanent HEPA Type Filter the permanent filter removes small visible...

Страница 5: ...MPORTANT WARNINGS sections of this manual Position your Therapure 440 at least one foot 12 inches from the wall Plug in the unit operating the Therapure 440 Safety 1 Do not place near fans 2 Keep both...

Страница 6: ...ure 440 to candle oil fireplace soot and smoke is not recommended and will require more frequent cleaning 1 2 4 3 operating the Therapure 440 CONTROLS SETTINGS Power Control To operate the Therapure 4...

Страница 7: ...will decrease the effectiveness of the lamp Never operate the unit without a filter or with a damaged filter UV lamp cover must be installed at all times The UV light from the UV lamp will result in s...

Страница 8: ...ntact Info for Warranty Service Therapure by Envion LLC P O Box 9159 Van Nuys CA 91409 8291 1 800 875 8577 www envionproducts com 2011 Envion LLC All Rights Reserved Patents pending troubleshooting Pr...

Отзывы: