HARDWIRING INSTRUCTIONS

The Envi Heater is available in some regions as a hardwired model: HW1012T / HW1022T / HW1023T (with built in thermostat)  
and  HW1012N / HW1022N / HW1023N (with no built in thermostat, instead a cover plate is in its place)

The Envi Heater can be hardwired direct to a mains supply, branch circuit or it can be hardwired to a line voltage external ther-
mostat of the same voltage as the heater (eg. 120v) or to an external switch or timer.  Consult the instructions for each of these 
control devices for specifi c wiring instructions.  The Envi Heater can also be wired as multiple heaters on the same circuit or 
controller.  For these Multi-Heater Hardwiring instructions please consult the installation page of the website www.eheat.com.  
The Envi Heater can also be hardwired to a 24volt thermostat using a 24v relay.  Please consult a certifi ed electrician and ensure 
that all electrical work is done in accordance with applicable electrical and building codes. 

CAUTION

: To prevent short circuits and electrical shocks turn the power off  at the main electrical panel before attempting the 

hardwiring installation or any repairs.  If the internal power cable (cordset) is damaged it must be replaced by the manufacturer.  

NOTE: 

This hardwired heater must be connected to the correct voltage circuit according to its model designation, ie.

(HW1012 = 120volts, HW1022 = 220volts and HW1023 = 230volts).  Disconnect the power supply before making wiring connec-
tions to prevent electrical shock and equipment damage.  

WIRING SCHEMATIC

NOTE:  The following wiring schematic is for a single Envi Heater installation to the applicable ac mains supply circuit and as-
sumes that the there are no external controls being wired into the unit.  For wiring of external controls (thermostat/switches or 
timers) please consult the website www.eheat.com for examples of external control wiring instructions.  

5.  Install heater on mounting clips (align right side fi rst) and  

make sure to press down fi rmly on the heater to ensure a 
secure fi t. You will hear it “snap” into place. (Fig. 5 above)

6.  (OPTIONAL) Install the third screw inside the bottom access 

door area (Fig. 6).  Replace the door.   Please note: for clarity 
the cordset is not shown exiting the heater.

For additional information visit www.eheat.com

MOUNTING INSTRUCTIONS (CONT)

Fig. 6

NEW LOCKING BAR FOR PERMANENT ATTACHMENT 

Fig. 7

The Envi Wall-Mounted Heater models now come with an additional 
method to permanently attach the heater to the wall.  A locking bar 
mechanism is built inside the heater, which is engaged by screwing an 
external locking screw into the bottom of the heater vent.  The lock-
ing screw and Hex/Allen Key are both provided in the mounting kit. 
This locking bar method is an alternate method to the existing bottom 
screw installation procedure above, however many customers will fi nd 
that the locking bar attachment method is suffi  cient by itself.

STEP 1 - Installing the Locking Bar Screw (Fig. 7) 

BEFORE YOU 

MOUNT THE HEATER TO THE WALL.  Take the locking bar screw out of 
the mounting kit and while the heater is laying fl at, use the Hex/Allen 
key provided to get the screw started in the hole at the bottom left 
hand side of the envi heater (Fig 1).  Screw the locking screw in about 
3/8 of an inch (Fig 2) but make sure you do not screw it in too far as it 
will obstruct the mounting holes at the back of the heater and prevent 
mounting on the wall.

STEP 2 – Mount the Heater.

 Attach the heater to the wall by following the rest of the mounting instructions shown above.

STEP 3 – Tighten Locking Screw 

(Fig 7) Follow the rest of the mounting instructions to ensure the heater is properly seated on 

the mounting clips and then tighten the locking screw to fi x the heater to the wall. DO NOT USE A POWER TOOL!!! 
DO NOT OVERTIGHTEN, just turn the screw until the locking bar presses gently up against the left hand mounting clip inside the 
heater. 

 Congratulations, you have now permanently mounted your Envi Heater !

Gently

 tighten Locking 

Screw using supplied 
Allen-key tool

Содержание HH1012T

Страница 1: ...Certifications p 7 Warranty p 8 MODELS COVERED BY THIS MANUAL 475 Watt 120 Volt Models HH1012T Plug In with Thermostat HH1012N Plug In No Thermostat HW1012T Hardwired with Thermostat HW1012N Hardwire...

Страница 2: ...to reduce the risk of fire electric shock and injury to persons including the following 1 Read all instructions before installing or using this heater 2 Extreme caution is necessary when any heater i...

Страница 3: ...o anchor locations and secure firmly to the wall anchors using the provided screws see Fig 3 DO NOT overtighten There should be a gap behind the mounting clip to hang the heater on 4 If you plan on us...

Страница 4: ...Install heater on mounting clips align right side first and make sure to press down firmly on the heater to ensure a secure fit You will hear it snap into place Fig 5 above 6 OPTIONAL Install the thir...

Страница 5: ...a screw driver can be used on the back of the heater and install the supplied protection grommet into the knockout hole The bottom access door is already removed and supplied in the mounting kit Pull...

Страница 6: ...rly attached to the mounting clips Be sure to mount in upright position with the thermostat knob on the top of the heater 2 Once the heater is connected press the front on off power switch and the POW...

Страница 7: ...position PRODUCT SPECIFICATIONS SAFETY LISTINGS COMMERCIAL FIRE SAFETY COMPLIANCE CALIFORNIA TITLE 24 CERTIFICATION insulation room draftiness room objects etc 4 To save energy and to reduce your heat...

Страница 8: ...er than those authorized by the Manufacturer Freight and Insurance cost for the warranty service 4 ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO A THREE YEAR DURA TI...

Отзывы: