Entryphone CA8 Скачать руководство пользователя страница 2

To 

enter

 programming mode (default master code 0000):

press

Error code:

  If at any time you make an error the unit will  

flash and beep 5 times. If this happens the unit will return to 

the start and expect you to re-key the sequence.

To 

change the master code

, for example to 8951 

(up to 8 digits allowed)

LED status      Sound

To 

leave

  programming mode:

press

To 

leave

  programming mode press

repeat 

to confirm

press

press

To 

add code to relay 1 

, for example to 5623

 

(up to 8 digits allowed)

repeat 

to confirm

To 

add code to relay 2 

, for example to 4455

 

(up to 8 digits allowed)

repeat 

to confirm

To 

add code to both relay 1 and 2

, for example to 2589

 

(up to 8 digits allowed)

press

press

press

press

press

press

press

repeat 

to confirm

To 

delete a code,

 for example to 5623

repeat 

to confirm

repeat 

to confirm

To 

change relay 1 time,

 for example to 4 seconds (range 0-20, 0=toggle mode)

To 

change relay 2 time,

 for example to 12 seconds (range 0-20, 0=toggle mode)

To 

turn keypad tones off

or on

To change the unit settings 

you must be in programming mode

.  The yellow LED 

indicates the unit is in programming mode; if it is not on you cannot  change any settings.

To 

return unit to factory defaults 

(be careful, all codes will be deleted)

The Entryphone CA8 is a coded access unit that can be 

supplied as a stand-alone unit or incorporated, to special 

order, into an Entryphone entrance unit.

Features include:

•  1-8 digit access codes

•  Master code to programme the unit

•  Up to 32 access codes, each operating either or both relays

•  Two 6 amp relays with change-over contacts

•  Anti-hack 30 second lock-out after 5 incorrect codes

•  Non-volatile memory in case of power failure

•  Confidence LED and beep (selectable) 

•  Back-lit keypad

•  Relay output times 1-20 seconds and toggle mode

•  Tamper-switch 

•  Input Supply 12/24 V AC or DC

•  Power Consumption 7mA min. / 250mA max

•  Operating temperature -20°C to + 50°C

Unit operation:

A user operates the unit by entering a valid programmed code 

followed by the star key. Depending on the set up for that code 

the unit will operate either or both the relays for the length of 

time set for that output.  Refer to the programming instructions 

to set the parameters.

Code Input

Relay 1 Relay 2

Beep

Validate

Error: 

 

If you key a wrong code, the unit will  flash 

and beep five times. 

Five invalid entries will cause the keypad to flash and for the 

unit to stop accepting further attempts for 30 seconds.

No.

Name

Code

R1

R2

M

Master

0000

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Programming record list

Please complete and keep in a safe place. Please remember to 

change the master code from its default of 0000.

Programming Instructions

Отзывы: